System with multiple subsystems in a single subnet 4.8.3 System with devices in different subnets 4.8.4 System with multiple subsystems in different subnets Port numbers System composition Constant voltage systems Amplifier selection Amplifier power and crest factor Battery calculation DYNACORD 2024-04 | V2.00 | Installation manual...
Page 4
Indicators and connections Installation 8.5.1 Parts included 8.5.2 Safety ground 8.5.3 Power supply 8.5.4 Lifeline 8.5.5 Amplifier outputs 8.5.6 Ethernet network 8.5.7 Reset to factory default Approvals Technical data Amplifier, 600W 8-channel (AD608) Introduction 2024-04 | V2.00 | DYNACORD Installation manual...
Crimp the ribbon cables into the IDC connector 17.5.7 Insert the IDC connectors 17.5.8 Pin assignment of the connectors 17.6 Approvals 17.7 Technical data Wall control panel (WCP-EU, WCP-US) 18.1 Introduction 18.2 Functions DYNACORD 2024-04 | V2.00 | Installation manual...
Page 8
Public Address server (APAS) 21.1 Introduction 21.2 Functions 21.3 Functional diagram 21.4 Indicators and connections 21.5 Installation 21.5.1 Parts included 21.5.2 Power adapter 21.5.3 Mounting bracket 21.5.4 Network connections 21.5.5 Configuration 21.6 Approvals 21.7 Technical data 2024-04 | V2.00 | DYNACORD Installation manual...
Safety information Read and keep these safety instructions. Follow all instructions and heed all warnings. Download the latest version of the applicable installation manual from www.dynacord.com for installation instructions. Information Refer to the Installation Manual for instructions. Follow all installation instructions and observe the following alert signs: Notice! Containing additional information.
(in accordance with the European Waste Electrical and Electronic Equipment Directive). To dispose of old electrical or electronic devices, you should use the return and collection systems put in place in the country concerned. 2024-04 | V2.00 | DYNACORD Installation manual...
About this manual The purpose of this installation manual is to provide all required information needed for the installation and interconnection of the Dynacord PROMATRIX 9000 products. It will guide new installers step‑by‑step and serves as a reference for experienced installers.
Each of the components listed may be redistributed under the terms of their respective open source licenses. Notwithstanding any of the terms in the license agreement you may have with Dynacord, the terms of such open source license(s) may be applicable to your use of the listed software.
Notice of liability While every effort has been taken to ensure the accuracy of this document, neither Dynacord nor any of its official representatives shall have any liability to any person or entity with respect to any liability, loss or damage caused or alleged to be caused directly or indirectly by the information contained in this document.
System introduction | en System introduction With PROMATRIX 9000, Dynacord has set a new standard in Public Address and Voice Alarm systems. With all system elements being IP‑connected and using state‑of‑the‑art technologies, this system combines cost efficiency and audio quality with ease of installation, integration and use.
Page 18
LCD call station (CSLD, CSLW), page PM9-CSLW LCD call station (CSLD, CSLW), page PM9-CSE Call station extension (CSE), page 195 PRA-CSBK Call station kit (CSBK), page 205 PRA-CSEK Call station extension kit (CSEK), page 2024-04 | V2.00 | DYNACORD Installation manual...
Page 19
Public Address server (APAS), page 261 PRA-APAL Advanced public address license PRA-PSM24 Power supply module (PSM24, PSM48), PRA-PSM48 page 268 Refer to the PROMATRIX 9000 Configuration manual for details on the software licenses. DYNACORD 2024-04 | V2.00 | Installation manual...
5000 m (16404 ft), an important requirement in Peru, Chile, India, China and other countries. At this altitude the air is less dense and the cooling capacity of air is decreased, making heat removal less effective. Also, the 2024-04 | V2.00 | DYNACORD Installation manual...
Page 21
PROMATRIX 9000 uses dynamic channel allocation. Because devices do not use static routing, amplifiers and call stations do not have a permanent audio connection to the system controller. That approach would limit the number of devices, since an 8‑channel DYNACORD 2024-04 | V2.00 | Installation manual...
Page 22
PROMATRIX 9000 allows for future changes to the areas covered by the system, with minimal or no equipment changes. Thus, initial planning is less sensitive to later small changes, which could impact profitability. 2024-04 | V2.00 | DYNACORD Installation manual...
Dynacord PROMATRIX 9000 installation manual. The Dynacord PROMATRIX 9000 VACIE must be installed and commissioned by those who have completed the appropriate training courses conducted by Dynacord. Once the...
Page 24
To ensure correct operation, the installer needs to ascertain that access level requirements are met. To maintain standards compliance, installers must follow the Dynacord installer guidelines. 2024-04 | V2.00 |...
Unpacking products The products should be unpacked and handled with care. If an item appears to be damaged, notify the shipper immediately. If any items are missing, notify your Dynacord representative. The original packaging is the safest container in which to transport products and can also be used to return products for service, if necessary.
Page 26
The mechanical construction of all 19"‑devices is rigid enough to mount the devices using only the holes in the mounting brackets to secure them in the rack. It is however considered good practice to mount support rails if the system is installed in a moving environment. 2024-04 | V2.00 | DYNACORD Installation manual...
Obey bending rules of cables and maximum pull force. – Be sure to firestop all cables that penetrate a firewall. – Use plenum rated cable where it is mandated. – Use fire resistant cable when it is mandated. DYNACORD 2024-04 | V2.00 | Installation manual...
When end-of-line supervision is used, take into account the maximum loudspeaker cable capacitance specified for the end‑of‑line device. – For compliance to UL 62368‑1 all loudspeaker wiring must be Class 2 (CL2); this requirement does not apply for compliance to EN/IEC 62368‑1. Conversion 0.75 2024-04 | V2.00 | DYNACORD Installation manual...
Page 29
This type of cable consists of pairs of wires twisted together. Without shielding, the symmetrical twist in the wires creates a balanced transmission line, which helps to reduce the electrical noise and EMI. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 30
This type of cable has both an overall braid Foil shield and foil shield, with individually foil tape screened twisted pairs. SF/FTP offers the maximum protection from RFI, EMI, crosstalk and alien crosstalk. It also provides 2024-04 | V2.00 | DYNACORD Installation manual...
Page 31
Use single mode or multi-mode glass fiber that fits the SFP transceiver. – The length of the fiber must not exceed the maximum as specified for the SFP transceiver, also considering the fiber diameter. DYNACORD 2024-04 | V2.00 | Installation manual...
Small Form‑factor Pluggable (SFP) transceiver module for a single mode or multi‑mode optical fiber connection, to facilitate long distance connections between decentralized clusters of devices. Two of the RJ45 network ports provide Power over Ethernet (PoE) to power a connected call station. 2024-04 | V2.00 | DYNACORD Installation manual...
Cipher Feedback Mode (CFB) for self‑synchronization, even when the audio stream is received much later than when it was started, or when some samples are lost during reception. Only six audio samples (125 us @ 48 kHz sample rate) are sufficient to re‑synchronize. DYNACORD 2024-04 | V2.00 | Installation manual...
OMNEO audio channel that is assigned for that call. This switch takes some time, and the call station operator cannot start speaking before the routing to the amplifiers is set up. The setup time for an overruling call can be approximately calculated by the formula 2024-04 | V2.00 | DYNACORD Installation manual...
– The switch must support Quality of Service (QoS), with strict priority, through differentiated services (DiffServ) on all ports, to ensure that PTP-synchronization and audio packets get priority over control packets. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 36
Has non-blocking backplane per switching port, such as 2 Gbps per port (for example 16 Gbps for an 8-port router) – Has a MAC address table of at least 1000 addresses per directly connected subnet. 2024-04 | V2.00 | DYNACORD Installation manual...
IP‑based network such as the LAN or WAN. There are multiple possibilities for assigning an IP‑address to a device: Link‑Local, DHCP and manual (static) assignment: DYNACORD 2024-04 | V2.00 | Installation manual...
Page 38
It is better to switch off the power to the system, remove the DHCP‑server and switch the system on again. 2024-04 | V2.00 | DYNACORD Installation manual...
This means that multicast traffic can make much more efficient use of available network bandwidth, but may also require the use of IGMP for management. Without IGMP, multicast traffic behaves as broadcast traffic. DYNACORD 2024-04 | V2.00 | Installation manual...
Dante or AES67 audio connections as an extension of the system, both as inputs and as outputs. These Dante/AES67 connections are not authenticated and not encrypted. They form a security risk, as no precautions are taken 2024-04 | V2.00 | DYNACORD Installation manual...
Page 41
Refer to Installation, page 249. – To enable SNMP, for example to use the Dynacord Network analysis tool OMN‑DOCENT, use SNMPv3. SNMPv3 provides much better security with authentication and privacy. Select the authentication level SHA and encryption via AES. To configure the switch accordingly, refer to Installation, page 249.
Page 42
| General installation procedures and instructions PROMATRIX 9000 Find all documentation and software related at www.dynacord.com in the Downloads section of the PROMATRIX 9000 products. Whenever you think you have identified a vulnerability or any other security issue related to a Bosch product or service, contact the Bosch Product Security Incident Response Team (PSIRT): https://psirt.bosch.com.
A PROMATRIX 9000 system can have some of its devices in a different subnet. For instance, a call station can be located in a different building. PROMATRIX 9000 uses OMNEO as a network protocol. When an OMNEO network uses multiple subnets, it requires the use of DYNACORD 2024-04 | V2.00 | Installation manual...
Page 44
ARK1123 C- 2.5 - 2.8 8.41 OMN-ARNIS synchronizer CTOS- single ENNLBO02- DC-to-DC Mean Well DDR-60L-12 converter Industrial CISCO IE-5000-12S1 15.2 ethernet 2P-10G switch Low Voltage CISCO PWR-RGD- DC Power LOW-DC-H Source for IE-5000 2024-04 | V2.00 | DYNACORD Installation manual...
Port numbers can be a key aspect of attack vulnerabilities and protections. Ports can be classified as either open or closed. Open ports have an associated application that listens for new connection requests. Closed ports do not. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 46
Unicast configuration) Network Time Protocol daemon PTPv1 Dante clock synchronization 319 - 320 PTPv2 AES67 clock synchronization 319 - 320 Multicast/ Unicast HTTPS Secure configuration web Unicast interface User ports 1024 - 49151 Protocol name Usage TCP/UDP Ports Transfer 2024-04 | V2.00 | DYNACORD Installation manual...
Page 47
Open Interface Secure 9403 Unicast PRAESENSA API (TLS) Object Control 9470 Protocol Secure OCP Secure Object 9471 Control Protocol DNS-SD Helper DNS-based 9474 Unicast Service Discovery Helper ARNI reconfirm ARNI confirm 9474 presence request DYNACORD 2024-04 | V2.00 | Installation manual...
Page 48
Architecture OCP.1 (control protocol) OCA OCP.1 Open Control TCP/UDP 49152 - 65535 Unicast Secure Architecture OCP.1 (secure control protocol) arnid ARNI daemon 49152 - 65535 Audio keep alive Keep alive 61440 - 61951 Unicast communication (for unicast Dante audio) 2024-04 | V2.00 | DYNACORD Installation manual...
Star wiring of loudspeakers should be avoided, as it often uses much more loudspeaker cable and cannot be supervised easily. DYNACORD 2024-04 | V2.00 | Installation manual...
(8), divide the number of zones by 8 and round up. – Example: Cluster A has 52 zones, so at least 52/8 = 6.5 amplifiers are needed, that means at least 7 whole amplifiers. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 51
It may help to split up such a zone in smaller sub-zones. DYNACORD 2024-04 | V2.00 | Installation manual...
These tones all have an RMS level at or below -9 dBFS. For custom made tones this should not be different. For instance, one of the multi‑sine alarm tones in the audio editing program Audacity may look like this: 2024-04 | V2.00 | DYNACORD Installation manual...
The power consumption of the PM9-SCL / PM9-SCS is relatively small, stable and hardly affected by system activities. It is powered from the 24 VDC output of the PM9-MPS3. Only the number of active Ethernet ports increases the power consumption. At least one port will DYNACORD 2024-04 | V2.00 | Installation manual...
Page 54
The average power consumption in snooze mode is somewhat larger than in sleep mode. When a call is being made or a tone played to one or more of the channels, the amplifier immediately requests the PM9-MPS3 to switch on the 48 VDC power supply again 2024-04 | V2.00 | DYNACORD Installation manual...
Page 55
It is not strictly needed for a PRA-ANS to be connected to a power source with a battery backup. If the PoE and the link disappear, the AVC deactivates for the affected zone. In this condition, calls will be at the highest level within the AVC control range. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 56
The power is supplied through a single PoE connection. The wall control panel does not affect alarm calls. Because of that, a PRA-WCP does not strictly need to be connected to a power source with a battery backup. 2024-04 | V2.00 | DYNACORD Installation manual...
Hall effect sensor. As a result, the clamp meter can attach onto a conductor and measure the current without disconnecting any wires. Make sure that the jaws of the clamp are around one of the wires connected to the battery. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 58
Make sure that the meter is set to measure the DC current. Not all current clamp meters can measure DC current. Do not use a clamp meter with AC current. For accurate results, keep the cable in the center of the hole. 2024-04 | V2.00 | DYNACORD Installation manual...
Multifunction power supply 0.43 10.53 + per active RJ45 port (2) 2 x 0.03 1.47 + per active SFP port 0.06 Total calculated battery capacity [Ah] 130.11 Required battery capacity (30% oversized) [Ah] DYNACORD 2024-04 | V2.00 | Installation manual...
In idle mode the power consumption of the amplifiers is considerably higher than in snooze mode and this will have an impact on the required backup power capacity of the UPS. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 62
It depends on how the aging of the batteries and Peukert’s law has been taken into account by the manufacturer of the UPS, whether this 6 kWh capacity is really sufficient or that 7 kWh would be a better choice. 2024-04 | V2.00 | DYNACORD Installation manual...
This power turns into heat. The same is true for the call stations, but they are typically placed outside the technical room and do not contribute to heat production in the room. PROMATRIX 9000 power amplifiers dissipate some power that is taken from the DYNACORD 2024-04 | V2.00 | Installation manual...
Page 64
When amplifiers are powered from a PRA-PSM48 power supply, also the heat loss of that power supply can be ignored, because it is already included in the heat loss of the connected amplifier. 2024-04 | V2.00 | DYNACORD Installation manual...
The MAC‑addresses are in the Dynacord vendor range 00:1c:44:xx:xx:xx or in the Audinate vendor range 00:1d:c1:xx:xx:xx. In many corporate networks the MAC‑addresses of networked devices need to be entered in a table in the DHCP‑server, to allow access. For that purpose the MAC‑addresses of each PROMATRIX 9000 device are printed on the...
Page 66
| From installation to configuration PROMATRIX 9000 – The configuration of all devices is described in the PROMATRIX 9000 configuration manual. 2024-04 | V2.00 | DYNACORD Installation manual...
Connecting the system controller Perform the following steps to get access to the PROMATRIX 9000 system controller: Install the Firmware Upload Tool on the PC, then automatically also the Dynacord DNS‑SD Service is installed. This service is needed to access PROMATRIX 9000 devices via their hostname instead of the IP‑address.
The solution is to allow physical loops, but create a loop-free logical topology using a protocol that disables redundant connections until they are needed because another connection failed. RSTP is such a 2024-04 | V2.00 | DYNACORD Installation manual...
The performance of a network will be better if the number of loops is smaller. The RSTP recovery time of the network after a link failure increases when the number of loops is higher. So, the hop count must be balanced against the number of loops. DYNACORD 2024-04 | V2.00 | Installation manual...
NTP settings and all event logs! For the call stations, the reset switch is below the cable cover, as indicated. It functions in the same way as the reset switch of the 19”-devices. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 71
For the call station kit, the reset switch is on the topside of the printed circuit board, as indicated. For the ambient noise sensor, the reset switch is under the removable front cover, as indicated. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 72
To activate this function: Use a pin or toothpick to press the reset button briefly. This will start the indicator test (LED test): – All LEDs will cycle through their possible color modes. 2024-04 | V2.00 | DYNACORD Installation manual...
Due to ongoing certification activities, the table is subject to change. For the latest information, check the certificates in the download section of these products on www.dynacord.com. Product SW version EN 54...
Dual redundant system controller option for highest system availability in mission- critical applications. – Recording facility on SD‑card for emergency audio logging and call stacking. The integrated call stacker automatically forwards recorded calls to previously occupied zones.* 2024-04 | V2.00 | DYNACORD Installation manual...
System controller (SCL, SCS) | en Sound quality – Audio‑over‑IP, using OMNEO, the Dynacord high‑quality digital audio interface, compatible with Dante and AES67; audio sample rate is 48 kHz with 24‑bit sample size. – Messages and tones are stored as high definition uncompressed wav‑files.
Page 76
OMNEO streams are always dynamic multicast streams, routed from the transmitter to one or more receivers. The Dante and AES67 streams are static and received and/or transmitted by the system controller, where they are encrypted, converted or decrypted. 2024-04 | V2.00 | DYNACORD Installation manual...
The device is designed to be installed in a 19"‑rack/cabinet. Refer to: Mounting the 19"-rack devices, page 25. 7.6.1 Parts included The box contains the following parts: Quantity Component System controller Set of 19"‑rack mounting brackets (pre‑mounted) DYNACORD 2024-04 | V2.00 | Installation manual...
SD memory card can be inserted. If no SD memory card is used, leave the dummy SD card in place. Use an SD memory card with a maximum size of 32 GB. Disable write-protection of the card. Insert the SD memory card in the slot. 2024-04 | V2.00 | DYNACORD Installation manual...
When no power supply redundancy is required, a single power supply can be used. Notice! For compliance to EN 50121‑4 for railway applications, the power connections to the 24‑48 V input may not be longer than 3 m. DYNACORD 2024-04 | V2.00 | Installation manual...
The reset switch resets the device to its factory default settings. This function is only to be used in case a secured device is removed from a system to become part of another system. See Device status and reset, page 70. DYNACORD 2024-04 | V2.00 | Installation manual...
< 1 s/yr off Accuracy (no NTP) < 11 min/yr off Daylight Saving Time (DST) Automatic Backup battery CR2032 Lithium cell Message/tone storage capacity Mono, uncompressed, 48 kHz, 16‑bit 90 min Number of messages/tones > 1000 SD card size 1 — 32 GB 2024-04 | V2.00 | DYNACORD Installation manual...
Page 83
Network audio latency 10 ms Audio data encryption AES128 Control data security Ports Reliability MTBF (extrapolated from calculated MTBF of PM9- 1,000,000 h AD608) Environmental Climatic conditions Temperature Operating -5 — 50 °C (23 — 122 °F) Storage and transport -30 — 70 °C (-22 — 158 °F) DYNACORD 2024-04 | V2.00 | Installation manual...
Page 84
1.75 in x 19 in x 15.7 in Rack unit (U) 19 in, 1 U IP rating IP30 Material (Case) Steel; Zamac Material (Frame) Zamak Color (RAL) RAL 9017 Traffic black Weight (kg) 5.80 kg Weight (lb) 12.80 lb 2024-04 | V2.00 | DYNACORD Installation manual...
Sound quality – Audio‑over‑IP, using OMNEO, the Dynacord high‑quality digital audio interface, compatible with Dante and AES67; audio sample rate is 48 kHz with 24‑bit sample size. – Large signal to noise ratio, wide audio bandwidth and very low distortion and crosstalk.
Page 86
– Backup analog audio lifeline input driving the spare amplifier channel to serve all connected loudspeaker zones in case both network connections, or the amplifier network interface, would fail. 2024-04 | V2.00 | DYNACORD Installation manual...
Caution! The chassis ground screw of an amplifier must be connected to protective ground before the amplifier is connected to a power supply. 2024-04 | V2.00 | DYNACORD Installation manual...
48 V inputs A and B in parallel to make use of the amplifier's internal dual power converters for fail safe redundancy and to avoid a supply supervision fault event. DYNACORD 2024-04 | V2.00 | Installation manual...
When the amplifier is powered from one or two normal 48 V power supplies, that do not have a lifeline interface, the power saving and audio bypass functions are not available. All other amplifier functions are still available. 123456 (MPSx) To create a lifeline connection, follow the procedure below. 2024-04 | V2.00 | DYNACORD Installation manual...
300 W load, which is connected to channel 1, no other channel can be loaded with more than 300 W anymore without exceeding the total maximum of 600 W. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 94
– No cable spurs or branches are allowed, because they will not be supervised. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 96
Connect an end-of-line device to the end-of-line connection terminals. These terminals are connected in parallel to output B, internally in the amplifier, to include supervision of the output B connection. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 97
Outputs: A on, B off Pilot tone: on Spare channel: yes Output fault response: – End-of-line fault on B: A and B on – Short circuit fault on A: A and B off DYNACORD 2024-04 | V2.00 | Installation manual...
Page 98
When the temperature continues to drop, the attenuation of the audio signals is lifted. The low severity Overheat fault resets. At an even lower temperature, the fans go back to the low speed mode to decrease the acoustical noise of the fans. 2024-04 | V2.00 | DYNACORD Installation manual...
The reset switch resets the device to its factory default settings. This function is only to be used in case a secured device is removed from a system to become part of another system. See Device status and reset, page 70. DYNACORD 2024-04 | V2.00 | Installation manual...
Nominal output voltage 100 V mode, 1 kHz, THD <1%, no load 100 VRMS 70 V mode, 1 kHz, THD <1%, no load 70 VRMS Nominal / rated power** All channels combined 100 V mode, load 16.7 ohm 600 W / 150 W 2024-04 | V2.00 | DYNACORD Installation manual...
Page 101
**Nominal power: EIAJ test standard, 1 kHz, 8/40 ms Rated power: RMS power, continuous Power transfer Power supply input A/B Input voltage 48 VDC Input voltage tolerance 44 — 60 VDC Power consumption (48 V) Sleep mode, no supervision 6.0 W Snooze mode, supervision active 7.5 W DYNACORD 2024-04 | V2.00 | Installation manual...
Page 102
Network interface Ethernet 100BASE‑TX, 1000BASE‑T Protocol TCP/IP Redundancy RSTP Audio/control protocol OMNEO Network audio latency 10 ms Audio data encryption AES128 Control data security Ports Reliability MTBF (extrapolated from calculated MTBF of PM9- 300,000 h AD608) 2024-04 | V2.00 | DYNACORD Installation manual...
Page 103
Dimensions (H x W x D) (mm) 44 mm x 483 mm x 400 mm Rack unit (U) 19 in, 1 U IP rating IP30 Material Steel; Zamac Color (RAL) RAL 9017 Traffic black Weight (kg) 8.10 kg DYNACORD 2024-04 | V2.00 | Installation manual...
Sound quality – Audio‑over‑IP, using OMNEO, the Dynacord high‑quality digital audio interface, compatible with Dante and AES67; audio sample rate is 48 kHz with 24‑bit sample size. – Large signal to noise ratio, wide audio bandwidth and very low distortion and crosstalk.
In case the amplifier and the power supply are mounted in two different racks, double power supply connections must be made, but even if both devices are in the same rack, it is recommended to use double connections for fail-safe redundancy. 2024-04 | V2.00 | DYNACORD Installation manual...
(pins 5 and 6). This signal is a backup audio signal for the connected amplifier in case its network interface or both network links would fail. The emergency call will then be DYNACORD 2024-04 | V2.00 | Installation manual...
Page 110
Insert each wire into the appropriate slot of the connector C. The wiring order is not critical, but use the same order for all lifeline cables in the system to minimize the risk of errors. – Use a flat blade screwdriver to tighten each connection. 2024-04 | V2.00 | DYNACORD Installation manual...
300 W load, which is connected to channel 1, no other channel can be loaded with more than 300 W anymore without exceeding the total maximum of 600 W. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 112
– No cable spurs or branches are allowed, because they will not be supervised. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 114
B is activated in case of interruption of one conductor. Connect an end‑of‑line device to output B, in parallel with the loudspeaker cable. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 115
Spare channel: yes Output fault response: – End-of-line fault on A: A and B on – End-of-line fault on B: A and B on – Short circuit fault on A: A off, B on DYNACORD 2024-04 | V2.00 | Installation manual...
Page 116
3 dB to decrease the load and the heat generation. An Overheat fault with severity low is generated. The audio signals remain present, though at a slightly lower level. 2024-04 | V2.00 | DYNACORD Installation manual...
21 devices in series. For redundancy a looped through network connection may be connected at both sides to create a loop. RSTP must be enabled in the system. DYNACORD 2024-04 | V2.00 | Installation manual...
600 W 70 V mode, all channels* 600 W Minimum loudspeaker load impedance 100 V mode, all channels* 16.7 ohm 70 V mode, all channels* 8.3 ohm Maximum cable capacitance 100 V mode, all channels* 2 uF 70 V mode, all channels* 2 uF 2024-04 | V2.00 | DYNACORD Installation manual...
Page 119
Level control resolution 1 dB Audio delay 0 ‒ 60 s Audio delay resolution 1 ms RMS power limiter Rated power Lifeline Sensitivity (100 V out) 0 dBV Mute attenuation > 80 dB Signal to Noise Ratio (SNR) > 90 dBA DYNACORD 2024-04 | V2.00 | Installation manual...
Page 120
Controller continuity Watchdog Temperature Overheat Rotation speed Network interface Link presence Network interface Ethernet 100BASE‑TX, 1000BASE‑T Protocol TCP/IP Redundancy RSTP Audio/control protocol OMNEO Network audio latency 10 ms Audio data encryption AES128 Control data security 2024-04 | V2.00 | DYNACORD Installation manual...
Page 121
Dimensions (H x W x D) (mm) 44 mm x 483 mm x 400 mm Rack unit (U) 19 in, 1 U IP rating IP30 Material Steel; Zamac Color (RAL) RAL 9017 Traffic black Weight (kg) 8.80 kg DYNACORD 2024-04 | V2.00 | Installation manual...
The enclosure size is compatible with the mounting provisions in most Dynacord loudspeakers for supervision boards or devices. It can also be reduced in size to fit most cable junction boxes.
End of line device Set of connection wires with thermal fuse 1 per box Safety information No tools are provided with the device. Parts check and identification End-of-line device Connection wires with thermal fuse DYNACORD 2024-04 | V2.00 | Installation manual...
The end‑of‑line device uses a 2‑pole push wire connector. – The stripped wire ends must be inserted into the connector completely, up to the insulation, to prevent that the wires can be touched. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 125
PROMATRIX 9000 End-of-line device (EOL) | en 125 Notice! For the PM9-EOL device, the maximum cable capacitance for reliable supervision is 80 nF. You can measure the cable capacitance when it is not clearly specified by the cable manufacturer. For both a shielded and an unshielded cable, the cable capacitance is measured with an LCR-meter between the two conductors.
Most Dynacord loudspeakers have a provision to mount the end‑of‑line device as a flat panel using the holes in the mounting plate. Caution! When PM9-EOL devices are mounted at a height above 2 m from the ground, special care should be taken to avoid that a device falls and may hurt a person. Caution! For compliance to NFPA 70 and CSA C22.1, the device must be mounted in a junction box.
Electrical connectivity Connector type 2-pole spring terminal Wire size (mm2) 0.13 mm2 ‒ 2.0 mm2 Wire size (AWG) 26AWG ‒ 14AWG Cable length (m) (maximum) 1000 m Maximum cable capacitance (nF) 80 nF Cable temperature range (ºC) -20 ºC ‒ 50 ºC Cable temperature range (ºF) -4 ºF ‒ 122 ºF DYNACORD 2024-04 | V2.00 | Installation manual...
Page 128
Dimension (H x W x D) (mm), box shape 60 mm x 45 mm x 18 mm Dimension (H x W x D) (in), box shape 2.4 in x 1.8 in x 0.7 in Degree of protection (IEC 60529) IP30 Material Plastic Color in RAL RAL 3000 Flame red Weight (g) 25 g Weight (lb) 0.055 lb 2024-04 | V2.00 | DYNACORD Installation manual...
Flexible, pre‑terminated battery cabling of fixed length included, with fuse and battery temperature sensor, for fast battery connection and predictive cabling resistance. – Accurate battery impedance measurement to monitor aging of the battery and supervision of battery connections. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 130
Automatic battery backup takeover from mains in case of mains failures. – Multi‑port network interface with RSTP‑support for recovery from a failing network connection. – Supervised audio lifeline to connected amplifiers, as backup for a failing amplifier network interface. 2024-04 | V2.00 | DYNACORD Installation manual...
Socket for SFP module Controller Audio processing (DSP) Mains to DC converter DC to DC converter Battery charger Control input processor Control output relay Lifeline audio output Lifeline supply output Lifeline control interface Diode Fuse DYNACORD 2024-04 | V2.00 | Installation manual...
Multifunction power supply Set of 19"‑rack mounting brackets (pre‑mounted) Set of screw connectors Battery connection set (wiring, fuse, temperature sensor) Mains power cord Safety information No tools or Ethernet cables are provided with the device. DYNACORD 2024-04 | V2.00 | Installation manual...
Never use two fuses, one on each side, because this would increase the series resistance of the cable assembly and the high peak currents of a system in emergency mode would result in voltage dips that could limit the maximum available output 2024-04 | V2.00 | DYNACORD Installation manual...
Page 135
These elements are in a series and are measured together. 3. Do not connect any external load to the battery directly. This will disturb the charging process. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 136
In order to prevent damage to the battery, also battery supervision still continues in the background and even most battery faults will be reported as usual (voltage too high, voltage 2024-04 | V2.00 | DYNACORD Installation manual...
Page 137
230 Ah. The charger typically charges such a battery within 48 hours (90 % in the first 24 hours). Fuse at battery side Putting the fuse (M) at the positive battery terminal, follow the connection procedure below. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 138
(N) is needed to prevent that the fuse is being shorted by the bolt (Q or U). Fuse at power supply side Putting the fuse (M) at the positive battery terminal of the power supply, follow the connection procedure below. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 139
The nut plastic caps provide additional protection against the short circuiting of the battery, to prevent the battery fuse from accidentally blowing. Insert the connector of the battery temperature sensor assembly (J) into the temperature sensor connector socket of the power supply. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 140
But even when less amplifiers are connected or less loudspeaker load is connected, it is still good to select a cable type and length that fits to a maximum configuration. Then, amplifiers and load can be added later without having to change battery cables. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 141
Due to this reduction of active material, new batteries and batteries that have been stored for longer periods of time also show a relatively high internal resistance. A battery fault can be reported when the battery circuit resistance exceeds the threshold value for the configured battery size. DYNACORD 2024-04 | V2.00 | Installation manual...
(primary) power source becomes unavailable. This alternate power source can also be used for PROMATRIX 9000, with or without local battery backup. 2024-04 | V2.00 | DYNACORD Installation manual...
This is especially useful when the amplifiers and the power supply are not in the same rack and the power supply cable is accessible or vulnerable. It is recommended to always use both connections. (AD60x) DYNACORD 2024-04 | V2.00 | Installation manual...
48 V converters to minimize battery power consumption even more. The power supplies and the amplifier channels go to snooze mode and wake up every 90 seconds briefly to perform the required supervision actions for timely fault reporting. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 145
Each pair of 48 V outputs A/B and the lifeline next to it belong to each other and are always connected to the same amplifier. Keep the cables together to avoid errors that could result in no sound in case of emergencies. DYNACORD 2024-04 | V2.00 | Installation manual...
B. Cross coupling is allowed, but may be confusing in case of fault finding. Caution! For compliance to UL 62368‑1 and CAN/CSA C22.2 No. 62368‑1 the power supply wiring must be Class 1 wiring (CL1); this requirement does not apply for compliance to EN/ IEC 62368‑1. 2024-04 | V2.00 | DYNACORD Installation manual...
Ethernet network The multifunction power supply has six Ethernet connection ports with a built‑in Ethernet switch, supporting RSTP. Follow the procedure below to connect the device to a network and other system devices. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 148
SFP sockets, or a combination of these. 2024-04 | V2.00 | DYNACORD Installation manual...
In case of a cable short‑circuit, the control input sees a very low resistance. A very high or very low resistance will be interpreted as a fault condition. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 150
An emergency call that started by an activated input proceeds when a connection fault occurs for that input. A lower priority action that is started by an activated input is aborted when a connection fault occurs for that input. 2024-04 | V2.00 | DYNACORD Installation manual...
The reset switch resets the device to its factory default settings. This function is only to be used in case a secured device is removed from a system to become part of another system. See Device status and reset, page 70. DYNACORD 2024-04 | V2.00 | Installation manual...
EN 54‑16 (0560-CPR-202190028) EN 54‑4 (0560-CPR-222190016) Maritime applications DNV GL Type Approval Emergency standard compliance Europe EN 50849 Regulatory areas Safety EN 62368‑1 Immunity EN 55024 EN 55035 EN 50130‑4 Emissions EN 55032 EN 61000-3-2 EN 61000-3-3 EN 61000‑6‑3 Environment EN/IEC 63000 Railway applications EN 50121‑4 2024-04 | V2.00 | DYNACORD Installation manual...
1.0 A Power over Ethernet (PoE 1‑2) Nominal DC output voltage 48 V Standard IEEE 802.3af Type 1 Maximum PD load 12.95 W Power consumption Mains powered Active mode, all outputs loaded <1150 W Battery powered Unloaded 5.2 W DYNACORD 2024-04 | V2.00 | Installation manual...
Page 154
Control interface Control input contacts (1-8) Principle Contact closure Galvanic isolation Supervision Resistance measurement Contact closed 8 — 12 kohm Contact open 18 — 22 kohm Cable fault detection <2.5 kohm / >50 kohm Minimum hold time 100 ms Maximum voltage to ground 24 V 2024-04 | V2.00 | DYNACORD Installation manual...
Page 155
Redundancy RSTP Audio/control protocol OMNEO Network audio latency 10 ms Audio data encryption AES128 Control data security Ports RJ45 5 (2 with PoE) SFP Reliability MTBF (extrapolated from calculated MTBF of PM9- 350,000 h AD608) DYNACORD 2024-04 | V2.00 | Installation manual...
Page 156
Dimensions (H x W x D) (mm) 88 mm x 483 mm x 400 mm Rack unit (U) 19 in, 2 U IP rating IP30 Material Steel; Zamac Color (RAL) RAL 9017 Traffic black Weight (kg) 11.80 kg 2024-04 | V2.00 | DYNACORD Installation manual...
‘polluted’ by the sound from the PA system itself, in this mode the ambient noise sensor must be mounted close to the expected noise location and away from the PA-loudspeakers to prevent volume runaway. – Front side LEDs show the operational status. DYNACORD 2024-04 | V2.00 | Installation manual...
MEMS microphone Audio processing (DSP) Controller Power over Ethernet 12.4 Indicators and connections Front‑side indicator Power on Green Device fault present Yellow Device in identification Green blinking mode Front‑side control (behind front cover) 2024-04 | V2.00 | DYNACORD Installation manual...
No tools or Ethernet cables are provided with the device. Parts check and identification Back box Sealing gasket Sensor base unit Front cover (black and white) Cable gland, 16 mm Connection cap Sealing gasket Wood screws 3 x 30 mm, TX10 Plugs 5 x 25 mm DYNACORD 2024-04 | V2.00 | Installation manual...
Refer to AVC and the positioning of Ambient noise sensors, page 280 for details on the installation of Ambient noise sensors. Refer to – AVC and the positioning of Ambient noise sensors, page 280 2024-04 | V2.00 | DYNACORD Installation manual...
If the back box is used, the position of the logo always corresponds to one of corners of the hexagonal back box, not with one the flat sides. DYNACORD 2024-04 | V2.00 | Installation manual...
– This screw is mandatory for compliance to IP65 or NEMA 4 protection. 12.5.8 Surface mounting outdoors 0.3 Nm 16.2 mm 16.2mm 22mm DYNACORD 2024-04 | V2.00 | Installation manual...
Page 164
22 mm wrench and 0.3 Nm torque. Install a short RJ45 connector to the Ethernet cable. – Use termination standard T-568A or T-568B, according to the local standard. Pull the cable 100 mm inside the back box. 2024-04 | V2.00 | DYNACORD Installation manual...
50 — 100 dBSPL Frequency range 50 Hz — 10 kHz Frequency response, +/-2dB 100 Hz — 5.5 kHz Sensitivity tolerance, pink noise 50 Hz — 10 kHz < 2 dB Directivity Omni‑directional Power transfer Power over Ethernet PoE IEEE 802.3af Class 1 Power consumption 1.6 W Nominal input voltage 48 VDC DYNACORD 2024-04 | V2.00 | Installation manual...
Page 166
131 x 71 mm (5.2 x 2.8 in) Dimensions device front cover (⌀xH) 131 x 10 mm (5.2 x 0.4 in) Ingress protection IP65 / NEMA 4 (with mounted front cover) Material enclosure Plastic (PC/ABS - UL94‑5VA) Color enclosure RAL9017 Color front cover RAL9017 and RAL9003 Weight 0.4 kg (0.88 lb) 2024-04 | V2.00 | DYNACORD Installation manual...
– Control input and output functions are configurable in the software. – LEDs indicate the operational status and the fault status of all inputs and outputs. DYNACORD 2024-04 | V2.00 | Installation manual...
13.3 Functional diagram Functional and connection diagram Internal device functions Power over Ethernet Controller OMNEO network switch Control input processor Supervision Control output relay Supervision current detector Current limited voltage source 2024-04 | V2.00 | DYNACORD Installation manual...
Control interface module, 16x8 Cable connector, 32-pole Cable connector, 28-pole Supervision resistors 13.5.2 DIN rail installation To install the device Install the interface module vertically on a 35 mm DIN rail, complying to the EN 60715 standard. 2024-04 | V2.00 | DYNACORD Installation manual...
Shake the device slightly to make sure that it is secure. To uninstall the device Push the module downwards until it stops. Tilt the device upwards. Pull the device from the rail. 13.5.3 Safety ground Connect the functional ground screw to safety ground. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 172
The ground connection is also required to comply with: – the EMC requirements of the EN 50130-4 for Voice Alarm systems – EN 50121-4 for Railways applications – EN 55024 for IT equipment and EN 55035 for Multimedia equipment regarding the immunity to slow surges. 2024-04 | V2.00 | DYNACORD Installation manual...
The type number of the device without the "M" and the dash: PRAI16C8 Note: This is an exception compared to the other PROMATRIX 9000 products. – A dash. – The last six hexadecimal digits of the hostname MAC address. DYNACORD 2024-04 | V2.00 | Installation manual...
Without supervision: Connect the other side of the cable to the activation switch or voltage free relay contact. 2024-04 | V2.00 | DYNACORD Installation manual...
Use a 2‑wire or 3‑wire cable and the 28-pole terminal plug (C), delivered with the device. Insert the near end wires of the cable into the appropriate slots of terminal plug. Connect the other side of the cable to the application to be activated. DYNACORD 2024-04 | V2.00 | Installation manual...
This means that the strobes flash at the same time as the others in the system. The tones from sounders are synchronized too. Several different, proprietary, types of synchronization signals are in use. NAC power supplies support different synchronization methods. 2024-04 | V2.00 | DYNACORD Installation manual...
Press and hold the Reset to factory default button. Power on the device by connecting a network cable with PoE. Keep the button pressed for at least another second. Release the button – The device resets and is functional again. DYNACORD 2024-04 | V2.00 | Installation manual...
Resistance measurement Contact closed 8 ‒ 12 kohm Contact open 18 ‒ 22 kohm Cable fault detection <2.5 kohm / >50 kohm Minimum hold time 100 ms Maximum voltage to ground 24 V Control output contacts 1‑8 Principle Contact switch over (Relay SPDT) Galvanic isolation 2024-04 | V2.00 | DYNACORD Installation manual...
Page 179
Storage and transport temperature -22 ‒ 158 °F Humidity (non-condensing) 5 ‒ 95 % Air pressure 560 ‒ 1070 hPa Operating altitude -500 ‒ 5000 m Operating altitude -1640 ‒ 16404 ft Operating vibration Amplitude < 0.35 mm Acceleration < 2 G Bump (transport) < 10 G (IEC 60068-2-27) Mechanical Enclosure Dimensions (W x H x D) (mm) 78 x 131 x 100 mm DYNACORD 2024-04 | V2.00 | Installation manual...
Page 180
180 en | Control interface module (IM16C8) PROMATRIX 9000 Enclosure Dimensions (W x H x D) (in) 3.1 x 5.2 x 4.0 in Ingress protection IP30 Body Material Aluminum Color RAL9017 Weight (kg) 0.57 kg Weight (lb) 1.3 lb 2024-04 | V2.00 | DYNACORD Installation manual...
Successful broadcast of announcements/messages and changes to the background music settings are clearly indicated. – Press‑to‑talk button gives tactile feedback and is recessed to prevent accidental use. – Built‑in monitor loudspeaker with volume control. DYNACORD 2024-04 | V2.00 | Installation manual...
Fixed microphone on a flexible stem Internal monitor loudspeaker Audio processing (DSP) Power over Ethernet OMNEO network switch Controller Press-To-Talk button PM9-CSLW Detachable fist microphone with Press‑To‑Talk or Start/Stop switch 4.3" Call status LED ring 2024-04 | V2.00 | DYNACORD Installation manual...
LEDs can be adjusted in four levels, from dark to bright with two steps in between. This applies from hardware version V1.01 onwards. Top side controls Press-To-Talk Button 4.3" full‑color capacitive touch screen DYNACORD 2024-04 | V2.00 | Installation manual...
In case of flush mounting, the rear or bottom must be vented. It is used as a heatsink. 14.5.1 Parts included The box contains the following parts: PM9-CSLD Quantity Component Desktop LCD call station 2024-04 | V2.00 | DYNACORD Installation manual...
PoE power to only one port, both Ethernet ports take PoE power for cable redundancy and supply redundancy. For best availability it is advised to connect each port to a different, independent PSE, such as a PM9-MPS3 multifunction power supply (ports 1 and 2) or a DYNACORD 2024-04 | V2.00 | Installation manual...
6 hexadecimal digits of its MAC‑address. Configuration is described in the PROMATRIX 9000 configuration manual. 2024-04 | V2.00 | DYNACORD Installation manual...
For compliance to DNV GL type approval, the line input must not be used. By connecting a cable to this input the radiated emission of the device would exceed the limit for the maritime radio band. DYNACORD 2024-04 | V2.00 | Installation manual...
The typical frequency response of the PM9-CSLD call station microphone is shown in the next diagram (black), together with the boundaries according to EN 54‑16, clause 13.12.3 (red). The frequency response has been measured at a distance of 20 cm (8 in) with 1/6 octave smoothing. 2024-04 | V2.00 | DYNACORD Installation manual...
LCD call station (CSLD, CSLW) | en 189 f [Hz] 14.5.7 Microphone connection diagram The microphone of the PM9-CSLW is detachable and uses a lockable 6-pin mini XLR connector with the following pin assignments. 10 k 10 k DYNACORD 2024-04 | V2.00 | Installation manual...
PM9-CSE, flush‑mounted on a 19 in panel of 5U height. The devices are fixed on the panel by clamping strips, behind the panel, that go into the adapter slots. In this case the M4 inserts are not used and the desktop stands are removed. 2024-04 | V2.00 | DYNACORD Installation manual...
See Device status and reset, page 70. 14.6 Approvals Emergency standard certifications Europe EN 54‑16 (0560-CPR-202190028) Maritime applications DNV GL Type Approval Emergency standard compliance Europe EN 50849 Regulatory areas Safety EN 62368‑1 Immunity EN 55035 EN 50130‑4 Emissions EN 55032 EN 61000‑6‑3 DYNACORD 2024-04 | V2.00 | Installation manual...
Maximum sound pressure level, at 1 m 75 dBSPL Volume control Mute, -40 dB — 0 dB Frequency range (-10 dB) 400 Hz — 8 kHz Line input Frequency range (-3 dB) 20 Hz — 20 kHz Signal to Noise Ratio (SNR) > 96 dBA Total Harmonic Distortion + Noise (THD+N) < 0.1% 2024-04 | V2.00 | DYNACORD Installation manual...
Page 193
Network interface Ethernet 100BASE‑TX, 1000BASE‑T Protocol TCP/IP Redundancy RSTP Audio/control protocol OMNEO Network audio latency 10 ms Audio data encryption AES128 Control data security Ethernet ports Reliability MTBF (calculated according to Telcordia SR‑332 Issue 1,000,000 h DYNACORD 2024-04 | V2.00 | Installation manual...
Page 194
2.44 in x 5.12 in x 7.44 in (in) IP rating IP30 Base Material Zamak Color in RAL RAL 9017 Traffic black Panel Material Plastic; Zamac Color (RAL) RAL 9017 Traffic black Weight (kg) 1 kg Weight (lb) 2.21 lb 2024-04 | V2.00 | DYNACORD Installation manual...
All assembling can be done with one standard Torx TX10 screwdriver. Labeling – Removable front cover for easy labeling with space for three lines of text per button. Button cap – Three button caps are included to prevent unintended activation of critical buttons. DYNACORD 2024-04 | V2.00 | Installation manual...
White Business call Blue Music Green Zone fault present Yellow (1-12) The brightness adjustment of the LEDs is only supported on devices with HW version 01/01 and higher. Top-side controls Selection (1-12) Button 2024-04 | V2.00 | DYNACORD Installation manual...
Safety information No tools or Ethernet cables are provided with the device. Parts check and identification Call station extension Patch cable Coupling plate Screw torx TX10 (x4) Button light ring (x3) Button cap (x3) DYNACORD 2024-04 | V2.00 | Installation manual...
The cable covers prevent that the RJ12‑cable can be pulled out. For the call station, the cable cover also prevents access to the Reset switch. Follow the same procedure for mounting an additional extension to an already mounted extension. 2024-04 | V2.00 | DYNACORD Installation manual...
Gently push a screwdriver or tweezers into the holes of the plastic label holders for the keys and lift them up to remove. Type in the texts for the title label and the key labels using the available template. Then print on paper and cut to size. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 200
Slide the metal top side label holder to the right to lock it in place. Mount the cover back on the extension body by first sliding the bottom side into the body, then tilt down until it snaps into place. 2024-04 | V2.00 | DYNACORD Installation manual...
Then place the original light rings back around the remaining buttons. Mount the cover back on the extension body by first sliding the bottom side into the body, then tilt down until it snaps into place. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 202
Notice! If more than the three button caps delivered with the device are needed, order a set of 30 button caps as a service item with the material number F.01U.399.317. 2024-04 | V2.00 | DYNACORD Installation manual...
Input voltage 5 VDC Input voltage tolerance 4.5 — 5.5 VDC Power consumption (indicators off / on) 0.1 W / 1.0 W Supervision Interconnection Link presence Processor Watchdog Reliability MTBF (extrapolated from calculated MTBF of PM9- 2,400,000 h CSLD and PM9-CSLW) DYNACORD 2024-04 | V2.00 | Installation manual...
Page 204
PM9-CSE Call station extension Dimensions (H x W x D) (mm) 62 mm x 130 mm x 189 mm IP rating IP30 Material Plastic; Zamac Color (RAL) RAL 9017 Traffic black Weight (kg) 0.40 kg 2024-04 | V2.00 | DYNACORD Installation manual...
– Local audio line input (with stereo to mono conversion) for connecting an external audio source. The audio channel will be available on the network and can be played in any loudspeaker zone. DYNACORD 2024-04 | V2.00 | Installation manual...
Supervision of all critical elements; the audio path is supervised, as well as the communication to the network. 16.3 Functional diagram Functional and connection diagram Internal device functions Audio processing (DSP) Power over Ethernet OMNEO network switch Controller 2024-04 | V2.00 | DYNACORD Installation manual...
It is designed to become part of a final product, combined with a user interface for selection of operational functions or zones, or used as stand‑alone call station with a pre‑configured zone selection. 2024-04 | V2.00 | DYNACORD Installation manual...
(G) on a 95 mm x 136 mm rectangular pattern. Slide the four studs into the slots of the board, one at each corner. For mechanical stability, all four must be used. To fix the studs on the mounting base, use self-tapping screws (K), head TX10, size 3x10 mm. 2024-04 | V2.00 | DYNACORD Installation manual...
5 mm thickness with one or more rectangular plate washers, or use a 5 mm panel. Insert the polarized cable connector into its 6‑pin socket on the board. Use the microphone holder to mount the microphone in place. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 212
Plug the lockable 6-pin connector of the microphone cable into the socket on the panel. To unlock the connector, press the unlock button with a sharp tool, such as a paper clip. 11.5mm 14.3mm 10 k 10 k 2024-04 | V2.00 | DYNACORD Installation manual...
CSBK is used, to change the volume of the buzzer for audible notifications. In the final product the level of the loudspeaker can be decreased by adding a series resistor, but the buzzer level has to be verified to fulfill the applicable standards. DYNACORD 2024-04 | V2.00 | Installation manual...
Wire color Indicator function Icon LED color Pin 1 Black Power on Green Pin 2 System fault Yellow Pin 3 White Microphone/call status (emergency priority) Pin 4 Green Microphone/call status (business Green priority) 2024-04 | V2.00 | DYNACORD Installation manual...
In combination with one to four PM9-CSE call station extensions for zone selection and/or other functions. When connected with PM9-CSE devices, the call station will automatically assign all connected extensions to itself and number the extensions in DYNACORD 2024-04 | V2.00 | Installation manual...
Page 216
1, so the load current on pin 1 and 2 together should be <1 A. This output is current limited to 0.8 A +/-20%. Because of this tolerance it is advised to keep the maximum load 2024-04 | V2.00 | DYNACORD Installation manual...
Fixate the cables with tie‑wraps and/or cable glands as a strain relief. The strain relief will prevent mechanical force applied to the exterior of a cable from being transferred to the electrical terminations within the connector and to the connector soldering pads. DYNACORD 2024-04 | V2.00 | Installation manual...
Caution! The line input socket is a very vulnerable connector because it is not mechanically secured by an enclosure. Only use with flexible cables and proper cable fixation. 2024-04 | V2.00 | DYNACORD Installation manual...
In case the final product that uses the PRA-CSBK may be part of different systems, make sure that the reset switch remains accessible and is not covered by e.g. the user interface panel. DYNACORD 2024-04 | V2.00 | Installation manual...
IEEE 802.3af Class 3 Power consumption Call station (business use) 3.2 W Call station (emergency use) 4.4 W Call station extension (via RJ12) 5 W maximum Input voltage tolerance 37 — 57 VDC Supervision Supervision Microphone Impedance Audio path Pilot tone 2024-04 | V2.00 | DYNACORD Installation manual...
Page 221
Temperature Operating -5 — 45 °C (23 — 113 °F) Storage and transport -30 — 70 °C (-22 — 158 °F) Humidity (non‑condensing) 5 — 95% Air pressure (operating) 560 — 1070 hPa Altitude (operating) -500 — 5000 m (-1640 — 16404 ft) Vibration (operating) Amplitude < 0.35 mm Acceleration < 5 G Bump (transport) < 10 G (IEC 60068-2-27) DYNACORD 2024-04 | V2.00 | Installation manual...
Page 222
222 en | Call station kit (CSBK) PROMATRIX 9000 Mechanical Enclosure (PM9-CSLW) Dimensions (HxWxD) 20 x 110 x 162 mm (0.8 x 4.3 x 6.4 in) Weight (excluding accessories) 120 g (0.26 lb) 2024-04 | V2.00 | DYNACORD Installation manual...
Authorities Having Jurisdiction. – All the indicators connected to the extension kit are part of the indicator test function of the connected call station kit. DYNACORD 2024-04 | V2.00 | Installation manual...
Internal device functions Controller 7-12 Zone status indicator Zone fault indicator 13-18 19-24 17.4 Indicators and connections Top side interconnections Input connection Output connection (RJ12) from PRA-CSBK (RJ12) to subsequent or previous PRA-CSEK PRA-CSEK 2024-04 | V2.00 | DYNACORD Installation manual...
Optionally, you can mount a second PRA-CSEK on top of the first PRA-CSEK, or next to it. The position of the mounting holes corresponds to the 95 mm x 136 mm rectangular pattern of the PRA-CSBK. Refer to – Vertical mounting, page 226 – Horizontal mounting, page 227 DYNACORD 2024-04 | V2.00 | Installation manual...
Plug the RJ12 connectors of the reversible interconnection cable B into the output socket of the first PRA-CSEK and into the input socket of the second PRA-CSEK. Mount the stacked boards on a flat surface or on a mounting plate, as shown before. 2024-04 | V2.00 | DYNACORD Installation manual...
Mount the second PRA-CSEK next to the first PRA-CSEK with the M3 x 14 inserts E and screws D. Plug the RJ12 connectors of the reversible interconnection cable B into the output socket of the first PRA-CSEK and into the input socket of the second PRA-CSEK. DYNACORD 2024-04 | V2.00 | Installation manual...
With the connector upside down, the polarizing tab of the connector should now be on the side of the ribbon cable. In the graphic, pin 1 and wire 1 have a dark color. 2024-04 | V2.00 | DYNACORD Installation manual...
For that reason, these switches are indicated as 2 (7-12). Plug the IDC connectors into the shrouded headers in the order X1500, X1501, X1503 and finally X1502, as shown in the graphic. DYNACORD 2024-04 | V2.00 | Installation manual...
The graphic shows the pin assignment of the connectors X1500 - X1503. In this graphic, the odd pins 1 - 39 are on the left side and the even pins 2-40 are on the right side. The pin 1 is top left, the pin 40 is bottom right. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 231
Blue LED 8 Blue LED 2 Blue LED 8 Red LED 2 Red LED 8 Red LED 2 Red LED 8 Yellow LED 2 Yellow LED 8 Yellow LED 2 Yellow LED 8 DYNACORD 2024-04 | V2.00 | Installation manual...
Page 232
4 mA per output at maximum brightness. A series resistor is not needed to limit the LED current. The LEDs can be dimmed in multiple steps, using Pulse Width Modulation (PWM). 2024-04 | V2.00 | DYNACORD Installation manual...
Operating relative humidity, non-condensing 5% – 95% Installation altitude (m) -500 m – 5,000 m Installation altitude (ft) -1,640 ft – 16,404 ft Operating vibration Amplitude (mm) < 0.35 mm Acceleration (G) < 5 G DYNACORD 2024-04 | V2.00 | Installation manual...
Page 234
Dimensions (H x W x D) (mm) 158 mm x 105 mm x 32 mm Dimensions (H x W x D) (in) 6.22 in x 4.13 in x 1.26 in Weight (g) 105 g Weight (lb) 0.23 lb 2024-04 | V2.00 | DYNACORD Installation manual...
– Selection through a single rotary knob with push action. – Clear user feedback through the backlit color LCD. – Optional access control through PIN entry to restrict operation to authorized staff. DYNACORD 2024-04 | V2.00 | Installation manual...
The device comes with a black and a white front cover and wall plate, exchangeable to match the environment. 18.3 Functional diagram Functional and connection diagram Internal device functions Power over Ethernet Controller 2024-04 | V2.00 | DYNACORD Installation manual...
– The PRA-WCP-US in a rectangular American-style box. This device PRA-WCP-US comes without wall plates, because the standard Decora size wall plates with a cutout of 1.375 inches x 2.75 inches can be used. DYNACORD 2024-04 | V2.00 | Installation manual...
1 - 8 of the Ethernet switch PRA-ES8P2S. Since the PRA-WCP only has one Ethernet port, it is impossible to make a loop through connection to another device. 2024-04 | V2.00 | DYNACORD Installation manual...
60 mm ~100 ~100 To surface-mount on a wall: Use a standard in-wall electrical junction box of sufficient depth. Thread the Ethernet cable in such a way it ends into the junction box. DYNACORD 2024-04 | V2.00 | Installation manual...
Until you select the new channel, the previous channel remains active and visible in the bottom bar. Scrolling through the channels list does not produce sound. In case no music is wanted, select the empty channel in the list. 2024-04 | V2.00 | DYNACORD Installation manual...
Technical data Electrical Display Display size (in) 1.77 in Display color Color Display type Display resolution (W x H) 128 px x 160 px Brightness 480 cd/m2 Power transfer PoE input PoE IEEE 802.3af Nominal voltage (VDC) 48 VDC DYNACORD 2024-04 | V2.00 | Installation manual...
Page 244
US single-gang with depth of 50 mm / 2 in IP rating IP20 Material Plastic (PC/ABS ‒ UL94-5VA) Color (RAL) (front cover with knob) RAL 9017 Traffic black; RAL 9003 Signal white Weight (kg) 0.10 kg 2024-04 | V2.00 | DYNACORD Installation manual...
It supports Power over Ethernet (PoE) and two Gigabit SFP combo ports. This Ethernet switch is an OEM switch, made for Dynacord by Advantech for use in Dynacord Public Address and Voice Alarm systems. It is a preconfigured version of the EKI-7710G-2CP- AE switch, optimized for PROMATRIX 9000.
19.3 Functional diagram Functional and connection diagram Internal device functions Power over Ethernet power source PWR1 OMNEO network switch PWR2 Socket for SFP module Controller DC to DC converter P-Fail Fault relay Console DYNACORD 2024-04 | V2.00 | Installation manual...
Switch Alarm SFP port disconnected factory reset or link down Front panel connections Port Network port 1‑8 Port Network combo port 1‑8 with PoE 9‑10 9‑10 Console Console serial RS232 cable COM port 2024-04 | V2.00 | DYNACORD Installation manual...
(default) IP‑address. Only when the configuration is to be changed, each switch must be individually connected to the configuration PC, one at a time, to make the changes. DYNACORD 2024-04 | V2.00 | Installation manual...
Especially when the switch is serving multiple PoE powered devices as PSE (Power Sourcing Equipment), its power consumption can raise to 140 W. The remaining power capacity of the 48 V supply is not sufficient anymore for an amplifier under various load conditions. 2024-04 | V2.00 | DYNACORD Installation manual...
EN 61000‑4‑3 EN 61000‑4‑4 EN 61000‑4‑5 EN 61000‑4‑6 EN 61000‑4‑8 Emissions EN 55032 class A EN 61000‑6‑4 FCC‑47 part 15B class A CAN ICES-003(A) CISPR 32 Environment EN IEC 63000 Shock IEC 60068‑2‑27 Freefall IEC 60068‑2‑32 Vibration IEC 60068‑2‑6 Railway applications EN 50121‑1 EN 50121‑3‑2 IEC 62236‑1 IEC 62236‑3‑2 IEC 60571 clause 5.4, 5.5 DYNACORD 2024-04 | V2.00 | Installation manual...
Page 254
254 en | Ethernet switch (ES8P2S) PROMATRIX 9000 Mechanical Enclosure Dimensions (HxWxD) 152 x 74 x 105 mm (6.0 x 2.9 x 4.1 in) Ingress protection IP30 Mounting TS35 DIN Rail (EN 60715), Wall‑mounting Case Aluminum Weight 1.3 kg (2.7 lb) 2024-04 | V2.00 | DYNACORD Installation manual...
10 km. These are OEM transceivers, made for Dynacord by Advantech for use in Dynacord Public Address and Voice Alarm systems. An SFP transceiver locks into the SFP socket of the PROMATRIX 9000 multifunction power supply and Ethernet switch.
For short distance transmissions multi‑mode fibers can be used using light with a wavelength of 850 nm, while single‑mode fibers typically support distances up to 10 km, using light with a wavelength of 1310 nm. Some third party dedicated SFP fiber transceivers 2024-04 | V2.00 | DYNACORD Installation manual...
SFP module, be sure that the receive fiber connector is connected to the transmitter connector on the remote end‑node device, and the transmit fiber connector is connected to the receiver connector on the remote node. DYNACORD 2024-04 | V2.00 | Installation manual...
Easy zone selection with picture representation of zones. – Control of background music sources and volume levels in selected zones. Music can be streamed from internal memory, but also from music portals on Internet. DYNACORD 2024-04 | V2.00 | Installation manual...
Connection and functional diagram PRA-APAS PROMATRIX 9000 HDMI HDMI ETH2 ETH1 DC 12V Internal device functions Router DC to DC converter Mains to DC converter Processor and storage Controller OMNEO network switch Power on 2024-04 | V2.00 | DYNACORD Installation manual...
3 and 4 Serial port Rear panel indicators Active/Link status Green Speed status Yellow Rear panel connections 12 VDC input Chassis ground HDMI HDMI display Super speed USB interface 1 and 2 Network port HDMI HDMI display interface DYNACORD 2024-04 | V2.00 | Installation manual...
The PRA-APAS is delivered with an external 12 VDC power adapter. Connect the adapter to the PRA-APAS through the DC input on the rear side. 21.5.3 Mounting bracket The comes PRA-APAS with a bracket to mount the device on a standard DIN-rail or on a flat surface. 2024-04 | V2.00 | DYNACORD Installation manual...
EN/IEC 61000‑4‑8 EN/IEC 61000‑4‑11 EN 55035 Emissions EN 55011 EN 55032 / CISPR 32 EN 61000‑6‑3 EN 61000‑6‑4 ICES 003 FCC 47 part 15B class A Environment EN/IEC 63000 Radio equipment EN 300 328 EN 301 893 21.7 Technical data Electrical Server PC Model ARK‑1124H‑S6A1E (OEM Advantech) DYNACORD 2024-04 | V2.00 | Installation manual...
Page 266
Model ADP-60KD B (Delta) Input voltage range 100 — 240 VAC Input voltage tolerance 90 — 264 VAC Frequency range 47 — 63 Hz Socket type input Output voltage 12 VDC Maximum output current 5 A Connector type output Lockable DC jack Efficiency level (DOE) 2024-04 | V2.00 | DYNACORD Installation manual...
Page 267
46.4 x 133 x 94.2 mm (1.83 x 5.24 x 3.71 in) Case Material Aluminum Color Black Weight 0.7 kg (1.55 lb) Enclosure power adapter Dimensions (W x H x D) 110 x 62 x 31.5 mm (4.33 x 2.44 x 1.24 in) DYNACORD 2024-04 | V2.00 | Installation manual...
PSM24 delivers 24 V at up to 10 A continuously, while the PRA-PSM48 delivers 48 V at up to 5 A continuously. These power supplies are OEM power supplies, made for Dynacord by Delta Power Supply, as a cost effective alternative to the PROMATRIX 9000 multifunction power supply PM9-MPS3 in case the additional functions and characteristics of the multifunction power supply are not needed.
Mains to DC converter PRA-PSM48 22.4 Indicators and connections Front panel indicator and control Output voltage Green Adjust Output voltage Rotary present adjustment control Front panel connections 24 VDC or 48 VDC Mains input output DYNACORD 2024-04 | V2.00 | Installation manual...
The PRA-PSM24 and PRA-PSM48 are built‑in units and must be installed in a cabinet or room (condensation‑free and indoor) that is relatively free of conductive contaminants. The mains power connection of these devices is not touch‑protected. 2024-04 | V2.00 | DYNACORD Installation manual...
Shake the unit slightly to ensure that it is secured. For dismounting the device: Pull or slide down the latch at the rear side bottom with a screwdriver. Tilt the device upwards. Release the latch, and pull the device from the rail. DYNACORD 2024-04 | V2.00 | Installation manual...
Use a torque of 0.5 Nm on the screws to secure the wire connections. For cable redundancy use two cables in parallel (2x2 wires) between the dual output connections of the power supply and the A and B inputs of the loads to be connected. 2024-04 | V2.00 | DYNACORD Installation manual...
EN/IEC 61000-3-2, Class A EN 61204-3 Environment EN/IEC 63000 Railway applications EN 50121‑4 (PRA-PSM48 only) 22.7 Technical data Electrical PRA-PSM24 Power transfer Mains power supply input Input voltage range 100 — 240 VAC Input voltage tolerance 85 — 264 VAC Frequency range 50 — 60 Hz DYNACORD 2024-04 | V2.00 | Installation manual...
Page 274
Maximum peak current 7.5 A Power consumption 265 W Active mode, rated power Heat loss Active mode, rated power 90 kJ/h (85 BTU/h) PRA-PSM24 and PRA-PSM48 Protection Overvoltage Automatic recovery Overload Automatic recovery Over-temperature Automatic recovery Reliability MTBF 500,000 h 2024-04 | V2.00 | DYNACORD Installation manual...
Page 275
Enclosure Dimensions (HxWxD) 121 x 85 x 124 mm (4.76 x 3.35 x 4.86 in) Ingress protection IP20 Mounting rail TS35 DIN Rail (EN 60715) Case Aluminum PRA-PSM24 Weight 1.10 kg (2.43 lb) PRA-PSM48 Weight 0.96 kg (2.12 lb) DYNACORD 2024-04 | V2.00 | Installation manual...
Use one or more Gigabit PoE Ethernet extenders/repeaters. Typically, up to four or five can be daisy chained, each one adding a new stretch of 100 m, up to around 600 m in total. The repeaters themselves are powered from the incoming PoE source and also 2024-04 | V2.00 | DYNACORD Installation manual...
IP-addresses to all networked PROMATRIX 9000 devices. Notice! The Dynacord modular fire panels AVENAR panel 2000 and AVENAR panel 8000, with firmware version 4.x or higher, can control the PROMATRIX 9000 system through the Open Interface of the PROMATRIX 9000 system controller. This connection is called the Encrypted Smart Safety Link.
Page 278
Command Prompt with a PC that is on the same network as the system controller and has an IP‑address in the same range, and supporting DNS‑SD. – For example, the system controller with control hostname PRASCL‑0b4864‑ctrl.local appears to have an IP‑address 169.254.164.232. Hostnames are case-insensitive. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 279
DHCP‑address range, which is the range between the Low IP Address and the High IP Address of the switch. In this case the IP‑address 192.168.1.99 is chosen, just below the DHCP‑address range. After a successful entry this will show up as follows: DYNACORD 2024-04 | V2.00 | Installation manual...
As such, the sensor location depends on the speaker placement and on the acoustical characteristics of the space where the sensor is located. Due to this complexity, rules to define exactly where sensors must be installed do not exist. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 281
(walls, floor, and ceiling) times the average absorption of the surfaces. On average, the relation between the volume (V) of a hall and its equivalent absorption surface (S) is: S = 2.2 V DYNACORD 2024-04 | V2.00 | Installation manual...
Page 282
If a sensor is placed too close to the crowd, it will pick up on the direct sound of individual conversations. The system will adjust the level only due to isolated conversations. Install the sensor where it will pick up the cumulative level of 2024-04 | V2.00 | DYNACORD Installation manual...
Page 283
In case of outdoor installation, the ambient noise sensors will be most likely in the direct sound field of the noise sources. Fewer sound reflections and reverberation occur outside of a completely enclosed space. In this case, install the sensors closer to DYNACORD 2024-04 | V2.00 | Installation manual...
Resilience of EOL-supervision for high frequency tones The basis of the end-of-line supervision of loudspeaker lines is the detection of a low-level 3 VRMS pilot tone of 25.5 kHz by the PM9-EOL, with feedback to the amplifier using the loudspeaker line itself.
DR M 2P 150 (953 204) for 150 V with replaceable module DR MOD 150 (953 014) – DR M 2P 255 (953 200) for 255 V with replaceable module DR MOD 255 (953 010) DYNACORD 2024-04 | V2.00 | Installation manual...
Action: Use secure connection via File menu and add the security user (PSK user name and key). In case the PSK is not available anymore, the concerning devices need to be reset to factory default via the local reset key on the device. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 288
Cause: There can be many reasons. – Action: A good way to start is to check the system fault log or the fault menu on the call station for a more detailed fault description. 2024-04 | V2.00 | DYNACORD Installation manual...
Dynacord continually works on improving and developing the software. Regularly check whether there is a new version of the software that provides additional benefits. Information and software downloads are available on the Dynacord PROMATRIX 9000 product pages on the internet (www.dynacord.com).
– In case no backup was available, start a new system configuration as described in the PROMATRIX 9000 configuration manual. Restart the application on the new system controller. Perform a system test. 2024-04 | V2.00 | DYNACORD Installation manual...
12. Perform a test by making calls to the zones associated with the new amplifier and check the audio presence. 13. Make a backup of the new configuration and store on a safe location. DYNACORD 2024-04 | V2.00 | Installation manual...
12. Perform a test by making calls to the zones associated to amplifiers powered from the new multifunctional power supply and check the audio presence. 13. Make a backup of the new configuration and store on a safe location. 2024-04 | V2.00 | DYNACORD Installation manual...
Disconnect the Ethernet cable from the original noise sensor. Connect the Ethernet cable to the new noise sensor. Connect the PC to the system, either to a spare port of the system controller or to one of the PM9-MPSx. DYNACORD 2024-04 | V2.00 | Installation manual...
Click Save and restart to store and activate the new configuration. 10. Acknowledge and reset the faults in the system. If the faults associated with the control interface module can be acknowledged and reset, the connection and configuration is correct. 2024-04 | V2.00 | DYNACORD Installation manual...
10. Perform a test and observe if the sound in the zone is as expected: – Select different background music channels. – Adjust the volume level. 11. Make a backup of the new configuration and store it in a safe location. DYNACORD 2024-04 | V2.00 | Installation manual...
26.1 Introduction The Dynacord PROMATRIX 9000 system is designed to operate as a VACIE (Voice Alarm Control and Indicating Equipment), providing emergency announcement functions in accordance with the requirements of international standards, while also providing functions for business announcement and background music.
Page 297
Disabled condition (9) Installation and location Y/N: The Dynacord PROMATRIX 9000 VACIE must be installed and commissioned by those who have completed the appropriate training courses conducted by Dynacord. Once the installation and commissioning process is complete, access to the VACIE is restricted to authorized personnel only.
Page 298
Amplifier Y/N: The PROMATRIX 9000 power amplifiers have a built‑in spare amplifier channel that takes over from a failing channel automatically. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 299
Amplifier supervision must be enabled in the configuration. The amplifier to loudspeaker cabling must be supervised. – Use a PM9-EOL end‑of‑line device for each loudspeaker line to detect interrupted or shorted loudspeaker lines. See section End-of-line device (EOL), page 122. –...
Page 300
The Open Interface is only allowed to be used as interface between a CIE and the VACIE in the case of the Smart Safety Link between the Dynacord modular fire panels AVENAR panel 2000 or AVENAR panel 8000 as CIE and the Dynacord PROMATRIX 9000 as VACIE.
EN 54-4:1997 + A1:2002 + A2:2006 EN 54-16:2008 Intended use: Fire safety Public Address and Voice Alarm system PROMATRIX 9000 Visit the PROMATRIX 9000 section of https://www.dynacord.com for - Provided options - Technical information - Declarations - Installation manual - Certificates...
27.1 Introduction The Dynacord PROMATRIX 9000 system is designed to operate as a PA/GA (Public Address/ General Alarm) system, providing emergency announcement functions in accordance with the requirements of international standards, while also providing functions for business announcement and background music.
Page 303
Other PROMATRIX 9000 products are not to be positioned in the vicinity of a magnetic compass. Installation Y/N: The following installation restrictions apply: – When separate PA and GA systems are installed, no single fault tolerance is required as the combination of both systems provides redundancy. DYNACORD 2024-04 | V2.00 | Installation manual...
Page 304
To protect buttons from being pushed accidentally, a button cap must be mounted on each button that can activate an emergency function. See sections Labeling, page 199 and Mounting a button cap, page 201 of this manual. 2024-04 | V2.00 | DYNACORD Installation manual...
Page 305
DNV‑GL Type Approval, for loudspeaker and power cabling, as well as for short distance CAT6A network cabling and for longer distance glass optical fiber cabling. DYNACORD 2024-04 | V2.00 | Installation manual...
The system devices shall be certified for EN 54, marked for CE and be compliant with the RoHS directive. Warranty shall be three years minimum. The system shall be a Dynacord PROMATRIX 9000 system.
28.2 System controller (SCL, SCS) The IP‑networked system controller shall be designed exclusively for use with Dynacord PROMATRIX 9000 systems. The system controller shall dynamically assign network audio channels for audio routing between system devices across multiple subnets. It shall support >100 simultaneous high-resolution audio channels (24‑bit, 48 kHz) for music routing and...
End-of-line device (EOL) Architects’ and engineers’ specifications The end‑of‑line device shall be designed exclusively for use with Dynacord PROMATRIX 9000 systems. The end‑of‑line device shall only require a connection with the end of the loudspeaker line to supervise its integrity. Supervision reliability shall not depend on the number of connected loudspeakers.
(2U). The multifunction power supply shall be certified for EN 54-4, marked for CE and be compliant with the RoHS directive. Warranty shall be three years minimum. The multifunction power supply shall be a Dynacord PM9-MPS3.
The call station extension shall be certified for EN 54-16, marked for CE and be compliant with the RoHS directive. Warranty shall be three years minimum. The call station extension shall be a Dynacord PM9-CSE. 28.11 Call station kit (CSBK) The IP‑networked call station kit shall be designed exclusively for use with Dynacord...
UL and CE and be compliant with the RoHS directive. Warranty shall be three years minimum. It shall be optimized for use with a Dynacord PROMATRIX 9000 system for public address purposes. The advanced public address server shall be a Bosch PRA-APAS.
IR light with a wavelength of 1310 nm, to cover glass fiber link lengths of up to 10 km. It shall be certified for EN 54‑16 in combination with Dynacord PROMATRIX 9000 systems for public address and voice alarm purposes. The transceiver shall be marked for UL and CE and be compliant with the RoHS directive.
BGM sources shall be available across the system while the volume shall be controlled in each system individually. The license for subsystem shall be used with the Dynacord PROMATRIX 9000 system controller, PM9-SCL. The license for subsystem PRAESENSA shall be a Bosch PRA-LSPRA.
Need help?
Do you have a question about the PM9-EOL and is the answer not in the manual?
Questions and answers