Adjustment - Pioneer PD-F906 Service Manual

File-type cd player
Table of Contents

Advertisement

PD-F906
26
3. Tracking Error Balance Adjustment
(hove LILI-NFL ARB)
@ Test mode
FOCUS servo —
CLOSE
SPDL servo
-* CLOSE
TRKG servo
-— OPEN
Innermost
TES}OISCN
circumference
<>
e
(1 TRK)
VR155
PLAY
MAIN BOARD ASSY
V: 10mV/div
H: 5mSee/div
MAIN BOARD ASSY
4. PICKUP @RADIAL / @TANGENTIAL DIRECTION TILT
ADJUSTMENT
(Ey IP y FOS FPWHAOS LY 2 YY 7 VAOM EIA)
®@ Test mode
FOCUS servo -
CLOSE
SPDL servo
-* CLOSE
TRKG servo
-—* CLOSE
TEST DISC
--+--44- 5 3
4A
AA
-2--
PLAY
Position where the screw is
visible through the adjustment
hole of the float base after
moving
toward
the outer
peripheral.
AAR?
L7O—bx—-2
OMBRILA
VY RA SHH)
Oscilloscope
AC Mode
V: 20mV/div
H: 200nSec/div
Probe(10:1)
MAIN BOARD ASSY

Advertisement

Table of Contents
loading

Table of Contents