7.2 DIAGNOSIS
7.2.1 ERROR CODE DISPLAY
Error history display in test mode
The previously generated errors (NG processing) can be confirmed in the test mode. Since the has a backup function, the error history is
memorized even if the power is turned off. (Memory holding time : About two days)
@ Put the unit into the test mode.
TEST MODE: ON
STOP all operations.
@ Press the "BEST" button of the keys on the main body.
"
w)
An error appears on the fluorescent indicator display by the above operation.
Example)
@®
—-—©--—
| AO!!!
o1
Il = 36:15
® Disc No.
: Error code
(Only 10's digit is valid.)
The previously generated 16 error codes (maximum) can be memorized. These error codes are displayed one at a time in the ascending order
by pressing the "BEST" button again.
Note : A product performs fail safe operation when an error occurs. At that time, an error code is memorized by the fail safe operation
Gfter the error ts eliminated.