Model Number Descriptions - Trane Performance Climate Changer UCCA Series Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Model Number Descriptions

Digit 1, 2, 3, 4 - Product Group
UCCA = Performance Climate Changer
Digit 5 - Configuration
A
=
Horizontal/front top with housed
fan
B
=
Horizontal/top front with housed
fan
C
=
Vertical/front top with housed fan
D
=
Vertical/top front with housed fan
E
=
Vertical/back top with housed fan
F
=
Vertical/top back with housed fan
G
=
Horizontal/front top with DDP fan
H
=
Horizontal/top front with DDP fan
J
=
Horizontal/bottom front with
housed fan
K
=
Horizontal/bottom front with
DDP fan
L
=
Vertical/front top with MI fan
M =
Vertical/top front with MI fan
N
=
Vertical/back top with MI fan
P
=
Vertical/front top with high static
MI fan
R
=
Vertical/top front with high static
MI fan
T
=
Vertical/back top with high static
MI fan
S
=
Special
Digit 6, 7 - Unit Size
03 =
Unit size 3
06 =
Unit size 6
08 =
Unit size 8
10 =
Unit size 10
12 =
Unit size 12
14 =
Unit size 14
17 =
Unit size 17
21 =
Unit size 21
25 =
Unit size 25
30 =
Unit size 30
Digit 8 - Unit Voltage
0
= No motor, controls, or electric
heat
A
=
200-208 volt/60 Hz/3 phase
B
=
230 volt/60 Hz/3 phase
C
=
460 volt/60 Hz/3 phase
D
=
575 volt/60 Hz/3 phase
S
=
Special
Digit 9 - Unit Type
0
=
Indoor unit
1
=
Outdoor unit
Digit 10, 11 - Design Sequence
**
=
Factory Assigned
Digit 12 - Coil, Drain Pan and Motor
Side
R
=
Polymer drain pan, RH coil/RH
motor
L
=
Polymer drain pan, LH coil/LH
motor
C
=
Polymer drain pan, RH coil/LH
motor
D
=
Polymer drain pan, LH coil/RH
motor
CLCH-SVX009L-EN
Digit 12 - Coil, Drain Pan and Motor
Side (continued)
E
=
Stainless steel drain pan, RH coil/
RH motor
F
=
Stainless steel drain pan, LH coil/
LH motor
G
=
Stainless steel drain pan, RH coil/
LH motor
H
=
Stainless steel drain pan, LH coil/
RH motor
S
=
Special
Digit 13 - Unit Coil #1 First in
Airstream
0
=
No unit coil #1
A
=
1 row preheat hydronic coil/9 fpi
B
=
1 row preheat hydronic coil/12 fpi
C
=
1 row preheat hydronic coil/14 fpi
D
=
2 row preheat hydronic coil /9 fpi
E
=
2 row preheat hydronic coil/12 fpi
F
=
2 row preheat hydronic coil/14 fpi
G
=
1 row preheat steam coil/6 fpi
H
=
4 row hydronic coil/9 fpi
J
=
4 row hydronic coil/12 fpi
K
=
4 row hydronic coil/14 fpi
L
=
6 row hydronic coil/9 fpi
M =
6 row hydronic coil/12 fpi
N
=
6 row hydronic coil/14 fpi
P
=
8 row hydronic coil/9 fpi
R
=
8 row hydronic coil/12 fpi
T
=
8 row hydronic coil/14 fpi
U
=
4 row DX coil/9 fpi
V
=
4 row DX coil/12 fpi
W =
4 row DX coil/14 fpi
Y
=
6 row DX coil/9 fpi
Z
=
6 row DX coil/12 fpi
1
=
6 row DX coil/14 fpi
S
=
Special
Digit 14 - Unit Coil #2 Second in
Airstream
0
=
No unit coil #2
A
=
1 row reheat hydronic coil/9 fpi
B
=
1 row reheat hydronic coil/12 fpi
C
=
1 row reheat hydronic coil/14 fpi
D
=
2 row reheat hydronic coil/9 fpi
E
=
2 row reheat hydronic coil/12 fpi
F
=
2 row reheat hydronic coil/14 fpi
G
=
1 row reheat steam coil/6 fpi
H
=
4 row hydronic coil/9 fpi
J
=
4 row hydronic coil/12 fpi
K
=
4 row hydronic coil/14 fpi
L
=
6 row hydronic coil/9 fpi
M =
6 row hydronic coil/12 fpi
N
=
6 row hydronic coil/14 fpi
P
=
8 row hydronic coil/9 fpi
R
=
8 row hydronic coil/12 fpi
T
=
8 row hydronic coil/14 fpi
U
=
4 row DX coil/9 fpi
V
=
4 row DX coil/12 fpi
W =
4 row DX coil/14 fpi
Y
=
6 row DX coil/9 fpi
Z
=
6 row DX coil/12 fpi
1
=
6 row DX coil/14 fpi
S
=
Special
Digit 15 - Coil Options
0
=
No coil option
1
=
Aluminum fin with galvanized
casing, 1/2 in. coil
2
=
Aluminum fin with stainless steel
coil casing, 1/2 in. coil
3
=
Aluminum fin with galvanized
casing, 3/8 in. coil
4
=
Aluminum fin with stainless steel
casing, 3/8 in. coil
5
=
Aluminum fin with galvanized
casing, 1/2 in. coil with extended
drain and vent
6
=
Aluminum fin with stainless steel
casing, 1/2 in. coil with
extended drain and vent
7
=
Aluminum fin with galvanized
casing, 1/2 in. coil, turb, without
extended drain and vent
8
=
Aluminum fin with stainless steel
casing, 1/2 in. coil, turb, without
extended drain and vent
9
=
Aluminum fin with galvanized
casing, 3/8 in. coil, with extended
drain and vent
A
=
Aluminum fin with stainless steel
casing, 3/8 in. coil, with extended
drain and vent
S
=
Special
Digit 16 - Controller Options
0
=
No control type
1
=
Unwired end devices
2
=
Control Interface
3
=
Tracer® UC600 unit controller
S
=
Special
Digit 17 - Electric Heat/Factory
Mounted Only
0
=
No electric heat
1
=
Electric heat with 1 stage
2
=
Electric heat with 2 stages
4
=
Electric heat with 4 stages
5
=
Electric heat with SCR control
S
=
Special
Digit 18, 19, 20 - Electric Heater kW
000 = No electric heat
006 = 6.0 kW
007 = 7.0 kW
008 = 8.0 kW
009 = 9.0 kW
010 = 10.0 kW
011 = 11.0 kW
012 = 12.0 kW
013 = 13.0 kW
014 = 14.0 kW
015 = 15.0 kW
016 = 16.0 kW
017 = 17.0 kW
018 = 18.0 kW
020 = 20.0 kW
022 = 22.0 kW
024 = 24.0 kW
026 = 26.0 kW
028 = 28.0 kW
030 = 30.0 kW
9

Advertisement

Table of Contents
loading

Table of Contents