Trane Comfort Coil KIT06654 Installer's Manual
Trane Comfort Coil KIT06654 Installer's Manual

Trane Comfort Coil KIT06654 Installer's Manual

Door kit

Advertisement

INSTALLER'S
GUIDE
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
Model:
KIT06654
KIT06655
KIT06656
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information
pack upon completion of work.

A. GENERAL

WARNING
s s
These instructions should be used only by quali-
fied individuals. These individuals should be
specifically trained and experienced in the installa-
tion of furnaces, related accessories, and comfort
conditioning components. Improper installation
can create a hazard which could result in property
damage, personal injury, or death.
These instructions do not cover all variations in sys-
tems or provide for every possible contingency. Further
information may be desired or particular problems arise
which are not covered sufficiently by these instructions.
Contact your local distributor or the manufacturer as
listed on the furnace nameplate.
APPLICATION TABLE
CASE
MODEL
MODELS USED ON
HEIGHT
TXC018,24,25,31-C-A,B
KIT06654 17.5
CCB18,24,30,36-A-A,B,C
TXC030,035,036,037,042,043-C-A,B
KIT06655 22.5
TXC031-E/S-A,B
CCB36,42,48-A-A,B,C
TXC048,049,050,060,061-C-A,B
KIT06656 30.0
TXC036,037,054,065-E/S-A,B
CCB60-A-A,B,C

B. INSPECTION

Check carefully for any shipping damage. This must be
reported to and claims made against the transportation
company immediately. Check to be sure all major com-
ponents are in the container. Any missing parts should
be reported to your supplier at once, and replaced with
authorized parts only.

Parts List:

Item
Description
1
Front Panel Section
2
Drill Screws
3
Grommets.
Template
4
(KIT06656 requires 2 templates)
Comfort Coil™ Door Kit

C. INSTALLATION

The kits allow for retrofit of an updated coil into an older
coil case. The updated coil has three tubing extensions
from the front panel of the coil case.Parts List:
1. Place the front panel of the coil case on a flat sur-
face.
2. Align the template to the upper left corner of the
front panel. See Figure 1.
3. Peel the backing from the template material and
stick the template to the panel as aligned in Step #2.
NOTE: There are two templates for the KIT06656.
The second template (B) is aligned to the line on the
bottom of the first template (A) and attached as previ-
ously stated.
4. Place the new panel section on top of the template.
5. Mark the screw holes on the coil front panel and
then place the new panel to the side.
Qty.
6. Drill a pilot hole for each of the marked screw holes.
1
7. Cut along the edge of the template as marked with
metal shears (aviation snips).
8
3
1 or 2
18-AH14D10-2A-EN
Figure 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Comfort Coil KIT06654 and is the answer not in the manual?

Questions and answers

Summary of Contents for Trane Comfort Coil KIT06654

  • Page 1 INSTALLER'S 18-AH14D10-2A-EN GUIDE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Comfort Coil™ Door Kit Model: KIT06654 KIT06655 KIT06656 IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work.
  • Page 2 About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

This manual is also suitable for:

Comfort coil kit0665

Table of Contents