abc PU00 Manual page 55

Table of Contents

Advertisement

Available languages

Available languages

Parameter
Parameter
Number
Name
Value Versus Min
P3-52
Output - AO1
Value Versus Max
P3-53
Output - AO1
Min Output
P3-54
Voltage/Current -
AO1
Max Output
P3-55
Voltage/Current -
AO1
Min Set Value from
P3-68
Keypad
Max Set Value
P3-69
from Keypad
Enable Analogue
P3-90
Input as Digital
Input
Function Selection
P3-91
for AI1 as DI
Function Selection
P3-92
for AI2 as DI
Parameter Group 4: Process PID and Other Controllers
Process PID
P4-00
Feedback Source
Process PID Set
P4-01
Source
Fiducial Value for
P4-02
Process PID
Set/Feedback
Process PID
P4-04
Control Logic:
Positive/Negative
Process PID Anti
P4-05
Windup
Cut-in Frequency
P4-06
for Process PID
Speed Mode
Proportional Gain -
P4-07
Process PID 1
Integral Time -
P4-08
Process PID 1
Differentiating
P4-09
Time - Process PID
1
Process PID
P4-13
Differential Limit
Error Tolerance
P4-14
Limit to Enable
Process PID
Value Range
0.00~200.00
0.00~200.00
0.00~P3-55
P3-54~10.00/20.00
-200.00~200.00
-200.00~200.00
0:Keep as Analogue Inputs
1:Enable Analogue Inputs as Digital Inputs
Same as P2-05
Same as P2-05
0:No Function
1:Terminal AI1
2:Terminal AI2
5:Pulse Input 1
20:Bus Communication
0:No Function
1:Terminal AI1
2:Terminal AI2
5:Pulse Input 11
10:Preset Value 0 + UP/DOWN
11:Multi Preset Value
20:Bus Communication
30:Keypad
0.0~3000.0
0:Positive
1:Negative
0:Disable;
1:Enable
0.0~200.0
0.0~10.00
0.01~655.35
0.00~10.00
1.0~50.0
0.0~200.0
53
Factory
Unit
Default
%
0.00
%
100.00
0.00
/4.00
10.00
/20.00
%
0.00
%
100.00
0
0
0
0
0
50.0
0
1
Hz
0.0
0.01
s
655.35
s
0.00
5.0
%
0.1
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pu01

Table of Contents