Terminal Functions
Terminals for power inputs from grid
Terminals for Power output to motor
Terminals for DC link supply or Load sharing
Terminals for Brake resistor
For ground connection
Note: 2.2kW/single phase 200V main circuit terminal sequence: L、N、 DC+、DC-、 BR、U、V、
EN
W. L and N are power input, DC+、DC- and BR are DC-link and braking, U and V 、W are power out
put.
4.2 Control terminals of PU01
0.37-7.5kW PU01
PU00 560kW-630kW
0.37-7.5kW
R/L、S、T/N
U、V、W
DC+、DC-
DC+、BR
11-22kW PU01
34
PU00 Terminal Name
11-22kW
30-630kW
R、S、T
R、S、T
U、V、W
U、V、W
DC+、DC-
DC+、DC-
DC+、BR
-