Nominal dimensions for
cable [mm
(inch)]
2
Nominal dimensions for
screw [mm(inch)]
Standard dimension
[mm(inch)]
B
Allowance [mm(inch)]
Standard dimension
[mm(inch)]
D
Allowance [mm(inch)]
Standard dimension
[mm(inch)]
d1
Allowance [mm(inch)]
E
Min. [mm(inch)]
F
Min. [mm(inch)]
L
Max. [mm(inch)]
Standard dimension
[mm(inch)]
d2
Allowance [mm(inch)]
t
Min. [mm(inch)]
f Connect the rated cables only .
f
f Connect using a driver which is able to apply the rated torque to the screws .
f
f If the terminal is loose, fire may occur caused by arc . If the terminal is connected too firmly, the terminal may be
f
damaged .
M4
M5
• When connecting cables, you can connect the cables to the electrical part or connect them through the holes
below depending on the spot .
CAUTION
• Run transmission wiring between the indoor and outdoor units through a conduit to protect against external
forces, and feed the conduit through the wall together with refirgerant piping .
• Remove all burrs at the edge of the knock-out hole and secure the cable to the outdoor knock-out using lining
and bushing with an electrical insulation such as rubber and so on .
• Must keep the cable in a protection tube .
• Keep distances of 50mm or more between power cable and communication cable .
• When the cables are connected through the hole, remove the Plate bottom .
4/6 (0 . 0 06/0 . 0 09)
10 (0 . 0 1) 16 (0 . 0 2)
4 (3/8)
8 (3/16)
8 (3/16)
9 . 5 (3/8) 15 (9/16) 15 (9/16)
±0 . 2
±0 . 2 (±0 . 0 07)
(±0 . 0 07)
5 . 6 (1/4)
7 . 1 (1/4)
+0 . 3
+0 . 3 (+0 . 0 11)
(+0 . 0 11)
-0 . 2 (-0 . 0 07)
-0 . 2
(-0 . 0 07)
3 . 4 (1/8)
4 . 5 (3/16) 5 . 8 (1/4)
±0 . 2
±0 . 2 (±0 . 0 07)
(±0 . 0 07)
6 (1/4)
7 . 9 (5/16) 9 . 5 (5/16)
5 (3/16)
9 (3/8)
9 (3/8)
28 . 5
30 (1-
20 (3/4)
(1-1/8)
3/16)
8 . 4 (1-
8 . 4 (1-
4 . 3 (3/16)
3/16)
3/16)
+ 0 . 2
+0 . 4
+0 . 4
(+0 . 0 07)
(+0 . 0 15)
(+0 . 0 15)
0(0)
0(0)
0(0)
1 . 1 5
0 . 9 (0 . 0 3)
(0 . 0 4)
Tightening Torque (kgf • cm)
ENGLISH-35
25 (0 . 0 3)
8 (3/16)
8 (3/16)
16
16 . 5
12 (1/2)
(10/16)
(10/16)
±0 . 2
±0 . 3 (±0 . 0 11)
(±0 . 0 07)
9 (3/8)
11 . 5 (7/16)
+0 . 3
(+0 . 0 11)
+0 . 5 (+0 . 0 19)
-0 . 2
-0 . 2 (-0 . 0 07)
(-0 . 0 07)
7 . 7 (5/16)
±0 . 2
±0 . 2 (±0 . 0 07)
(±0 . 0 07)
11 (3/8)
13 (1/2)
15 (5/8)
13 (1/2)
33 (1-
34 (1-3/8)
5/16)
8 . 4 (1-
8 . 4 (1-3/16)
3/16)
+0 . 4
+0 . 4 (+0 . 0 15)
(+0 . 0 15)
0(0)
0(0)
1 . 4 5
1 . 7 (0 . 0 6)
(0 . 0 5)
12~18
20~30
35 (0 . 0 5)
50 (0 . 0 7) 70 (0 . 1 0)
8 (3/16)
8 (3/16)
16
22 (7/8)
22 (7/8)
(10/16)
±0 . 3
±0 . 3 (±0 . 0 11)
(±0 . 0 11)
13 . 3 (1/2)
13 . 5 (1/2)
+0 . 5
+0 . 5 (+0 . 0 19)
(+0 . 0 19)
-0 . 2 (-0 . 0 07)
-0 . 2
(-0 . 0 07)
11 . 4
9 . 4 (3/8)
(7/16)
+0 . 3
(+0 . 0 11)
±0 . 2 (±0 . 0 07)
-0 . 2
(-0 . 0 07)
17 . 5
12 . 5 (1/2)
(11/16)
13 (1/2)
14 (9/16) 20 (3/4)
43 (1-
38 (1-1/2)
50 (2)
11/16)
8 . 4 (1-
8 . 4 (1-3/16)
3/16)
+0 . 4
+0 . 4 (+0 . 0 15)
(+0 . 0 15)
0(0)
0(0)
1 . 8 (0 . 0 7)
1 . 8 (0 . 0 7)
Communication : F1, F2
3phase AC power : L1(R), L2(S), L3(T), N
1phase AC power : L, N
8 (3/16)
24 (1)
±0 . 4
(±0 . 0 11)
17 . 5
(11/16)
+0 . 5
(+0 . 0 19)
-0 . 4
(-0 . 0 15)
13 . 3 (1/2)
±0 . 4
(±0 . 0 15)
18 . 5 (3/4)
51 (2)
8 . 4 (1-
3/16)
+0 . 4
(+0 . 0 15)
0(0)
2 . 0
(0 . 0 78)

Advertisement