7.5 Air duct components in freezing chamber and fan motor
Air duct components in freezing chamber
All accessories in the freezing chamber should be
dismantled before removing the air duct components.
1) Remove 1 screws on the cover plate of the
freezing air duct using a cross screwdriver.
2) Pull out the connector terminal of the fan motor.
Fan
The fan is fastened with clasps and can be removed
directly; Change the fan, the reverse operation for
assembly
Damper assembly
7.6 Evaporator and Defrost system
Evaporator in freezing chamber
1) Remove the air duct components in freezing
chamber.
2) Disconnect all connectors.
3) Remove the welding on inlet and outlet tubes.
4) Remove one screws which are used to fix the
evaporator and remove the evaporator.
Service Manual_2020-V1.0
None
28