Page 1
Service Manual BMF No Frost Series Applicable Models Model Code Applicable Models HD-332RWEN CE-BCD255WE-JT 22031020008041 The picture in this service manual is only for reference, and specific appearance and configuration are subject to the real product. This manual mainly teaches the method, the specific work skill needs engineer to...
Page 2
Manufacturers or distributors are not responsible for the content of the Manual and interpretation thereof. Midea Refrigerators Technical Maintenance Manual Copyright @2017 All rights reserved. Replication of all or part of the Manual in any forms shall not be allowed without written approval by the Overseas Sales Corporation of Midea Refrigerators.
Service Manual_2020-V1.0 Contents 1. SIGNIFICANT UPDATE NOTES (NONE) ......................5 2. SAFETY WARNING CODE ............................6 2.1 W ........................... 6 ARNING FOR OPERATION SAFETY 2.2 S ......................... 8 AFETY INSTRUCTION FOR REFRIGERANT 3. INSTALLATION AND COMMISSIONING ......................9 3.1 H ................................... 9 ANDLING ........................
Page 4
Service Manual_2020-V1.0 ........................... 36 8.2 R EPLACEMENT OF SENSORS 8.3 S ......................37 ENSOR WITHOUT TERMINAL REPLACEMENT (R/T) ............................. 38 8.4 S ENSOR RESISTANCE 9. FUNCTION AND OPERATION ..........................40 ............................. 40 9.1 D ISPLAY OPERATION PANEL ..................................40 9.2 D ISPLAY 9.3 S .............................
Service Manual_2020-V1.0 2. Safety Warning Code 2.1 Warning for operation safety Important Safety Instructions CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN This symbol indicates that dangerous voltage constituting a risk of electric shock is present within your freezer. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying your freezer.
Page 7
Service Manual_2020-V1.0 CONNECTING ELECTRICITY Electrical Shock Hazard. Failure to follow these instructions can Plug into a grounded 3-prong outlet. result in death, fire, or electrical shock. Do not remove the ground prong. Do not use an adapter. WARNING Electric Shock Hazard Failure to follow these instructions can result in electric shock, fire, or death.
Service Manual_2020-V1.0 13) Do not store or use gasoline or any flammable liquids inside or in the vicinity of this freezer. 14) Do not use extension cords or ungrounded (two-prong) adapters with this freezer. If the power cord is too short, have a qualified electrician install an outlet near the freezer. Use of an extension cord can negatively affect the freezer’s performance.
Service Manual_2020-V1.0 3. Installation and commissioning 3.1 Handling Handling 1)Protect the refrigerator in moving it,Same as shown as lef t photo, please move it by handcart with cushion 2)Remove all packing materials and bottom cushion, the m ove into house for placement 3)After moving it to appropriate location, wait for 2 hours bef ore power on.
Page 10
Service Manual_2020-V1.0 Push the refrigerator into the cabinet and adjusted it to make the baffle flange touch the edge of the cabinet, and the supporting limit is hooked to the bottom edge of the cabinet. Fix the lower support with screws, and cover the screw cap.
Page 11
Service Manual_2020-V1.0 Fix the top baffle to the top of the cabinet with screws, and cover the screw cap. The lower door of the cabinet is opened to the maximum angle, and the lower door of the refrigerator is opened to the corresponding position. Sliding the block to make inner edge align with the door edge, then fix the block to the door with screw and cover the screw cap.
Service Manual_2020-V1.0 The sealing strip in the accessory is sealed in the gap between the cabinet and the refrigerator. Installation is complete. 3.4 Leveling of the refrigerator Leveling of the refrigerator If the refrigerator cannot be placed steadily, adjust the footing to level it.
Service Manual_2020-V1.0 3.5 Left or right open door reversal 1. 。Power off the refrigerator, and remove all objects from the door trays. 2. Remove the upper hinge and hole caps of refrigerator door. 3. Remove the refrigerator door, the bottom hinge and the hole cover.
Page 14
Service Manual_2020-V1.0 5. Remove the fixed block of refrigerator door and rotate it for 180° ,assemble it on other side of refrigerator door. 6. Remove the upper hinge of refrigerator door. 7. Remove the freezer door, the bottom hinge and the hole caps.
Page 15
Service Manual_2020-V1.0 8. Exchange the F:bottom hinge and F:upper hinge ,then assemble them. 9. Remove the fixed block of refrigerator door and rotate it for 180° ,assemble it on other side of refrigerator door. 10.Finished...
Service Manual_2020-V1.0 4. Main parts and external dimension 4.1 Main parts (The picture is only for reference, and specific appearance and configuration are subject to the real product) Refrigerator chamber Freezer chamber ❶R wind channel ❾F wind channel ❷R air flue ❿Pizza box ⓫...
Depth to match the cabinet (The picture is only for reference) 4.3 Midea product serial number and location 1) Product Serial Number — Including order number, production date and other information. When the product occur problem, it needs to be recorded or photographed and provided to us.
Page 18
Service Manual_2020-V1.0 2)Paste location Some products also have S/N on the lower part of the right side of the Cabinet.
Service Manual_2020-V1.0 6.3 Circulating route of cooling air 6.4 Welding points in chambers or foam layer 1) Welding points on freezer evaporator Welding point Pipe outer diameter (mm) Copper pipe: Φ6 Aluminum pipe: Φ6.35 1-Freezer capillary and inlet of evaporator Copper pipe: Φ6 Aluminum pipe: Φ6.35 2-Heat transition tube and outlet of evaporator...
Service Manual_2020-V1.0 6.5 Welding point in the compressor case Welding point Pipe outer diameter (mm) Steel pipe: Φ4. 0 Copper pipe: Φ5.0 1-Outlet of anti-condensation tube and inlet of dry filter Copper pipe: Φ6.0 Copper pipe: Φ6.0 2-Heat transition tube and Suction connection tube Copper pipe: Φ2.8 Copper pipe: Φ1.8 3-Outlet of dry filter and inlet of freezer capillary...
Service Manual_2020-V1.0 7. Dismantling of parts 7.1 Parts on the door Door seal Door seal is installed into door liner groove. 1)Open the refrigerator door. 2)Take the door seal ① out of door liner. Door tray While squeezing it inward, lift up the baffle and take it out from refrigerator liner.
Service Manual_2020-V1.0 Shelves 1)Lift up the division plate with a proper force and pull it out towards yourself. Drawer The drawer is located at the bottom of freezing chambers; 1) Pull the drawer out completely 2) Lift it up slightly and take it out from the refrigerator. 7.3 Light system Light Light of the refrigerating chamber is located upper...
Service Manual_2020-V1.0 Light switch There is a light switch on the side wall of the refrigerating chamber. 1)Loosen the hook with small normal screwdriver and pull out the switch until the wire connector reveals. 7.4 Air duct components refrigerating chamber and fan motor Air duct components in freezing chamber All accessories in the freezing chamber should be dismantled before removing the air duct components.
Service Manual_2020-V1.0 7.5 Air duct components in freezing chamber and fan motor Air duct components in freezing chamber All accessories in the freezing chamber should be dismantled before removing the air duct components. 1) Remove 1 screws on the cover plate of the freezing air duct using a cross screwdriver.
Service Manual_2020-V1.0 Components on the evaporator Defrost thermostat None Fuse The fuse is located on top of the evaporator 1) connect the fuse connector. 2) Cut off the band which fixes the fuse. 3) Separate the fuse and the evaporator. *Don’t break the welding of the evaporator in case that only the fuse needs to be replaced.
Page 30
Service Manual_2020-V1.0 3)Cut off the compressor pipeline.-❶Cut off the process pipeline.-❷Cut off the low-pressure muffler.-❸Cut off the high-pressure exhaust pipe. 4-1)Remove the screws(for some models) -Two screws outside -One screw inside 4-2)Remove the metal clamp(for some models) -Disassembly the metal clamp that is fix the electric appliance shield 5)Remove the clipping strip Slowly pull it out...
Page 31
Service Manual_2020-V1.0 6)Remove the protective cover -Pry the protective cover slowly from the upper part, -Pull it out and remove it. 7)Remove the starter and protector Unplug the starter and protector (you can use a screwdriver to pry it slowly) 8)Loosen the screw of the compressor bottom plate, remove the floor together with the compressor from the box.
Page 32
Service Manual_2020-V1.0 10)Use Pipe cutter cut off the condenser tube❽, then Shear off capillary ❾ by the capillary tube scissors. 11) Replace the compressor and welding the compressor pipeline.-❿Welding the process pipeline.-⓫Welding the low-pressure muffler.-⓬Welding the high-pressure exhaust pipe. 12)Replace the filter, Cu-Fe tubes welding ⓭ used Ag welding rod, Cu-Cu tubes welding ⓮...
Page 33
Service Manual_2020-V1.0 15)Use the vise grip pliers clamp the middle of the process pipe, then seal welding process tube⓯⓰. Piping system in the compressor case ❶.Drain tray ❻.main control board box assembly ❷. condenser(enter) ❼.compressor ❸.condenser(exit) ❽.suction transition tube ❹.anti-dew tupe assembly(exit) ❾.Power wire ❺.anti-dew tupe assembly(enter) ❿.dry filter...
Service Manual_2020-V1.0 2)Replace the drain tray, the reverse process can complete installation. 3) Remove the screws from the back of cabinet assembly 4)Replace the drain tray, the reverse process can complete installation. 7.8 Display control board Display control board 1) Pry open the buckle of the display control board installation box with a straight screwdriver 2)...
Service Manual_2020-V1.0 7.9 Main control board Main control board 1) The main control board box is located compressor case 2) Remove 2 screws using a cross screwdriver 3) Pry open the buckle of the main control board installation box with a straight screwdriver 4)...
Service Manual_2020-V1.0 8. Temperature sensing system 8.1 Position of sensors Position of sensors Have 4 sensors ① Sensor in freezing chamber ② Sensor in refrigerating chamber ③ Sensor in Variable temperature chamber ④ Ambient temperature or humidity sensor ⑤ Ice machine sensor ⑥...
Service Manual_2020-V1.0 Defrost sensor in refrigerating chamber Before remove the sensor, the refrigerating duct assembly should be removed Ambient temperature sensor Sensor position in the upper of the box Defrost sensor The defrost sensor is located on top of the evaporator. 1)...
Take out a new sensor to cut the head of sensor. (Spare parts code:11201007000795) Its technical specifications apply to all MIDEA refrigerators. Strip off the head of the sensor and connect it. Wrap the two wires together with insulation tape.
Service Manual_2020-V1.0 9. Function and operation 9.1 Display operation panel Icons Button ❶ One gear ❺ Gear set button ❷ Two gear ❸ Three gear ❹ Four gear 9.2 Display At the first time of power-on, the display screen will be bright for 3 seconds and then according to the three gear to show operation Normal operation display: 1)When failure occurs, the corresponding LED light group will display fault code (circular display);...
Service Manual_2020-V1.0 9.4 lock and unlock Settings In the lock state, long press the SET key for 3 seconds to unlock the device before it can operate. When the unlock is effective, all LED lights will flash for 2 times. In the lock state, all LED lights will flash for 2 s econds to remind the user to unlock the device first.
Service Manual_2020-V1.0 refrigerating sensor according to the method in described in Article 8.5 and then inspect the sensor against the resistance value table in 10.8. Step 3: Replace main control board Step 4: Replace electrical wiring main harness Step 1: Check whether the terminal CN8 is well stuck, pull out the terminal and re-stick it in place Step 2: Check to see if there are foreign...
Page 43
Service Manual_2020-V1.0 enter into button for the second time LED indicators light off, then the compressor and forced cooling the fan will start working mode In forced cooling mode, if no then the refrigerator will exit the test mode and button is pressed within 36 hours, return to normal operation mode Select to...
Service Manual_2020-V1.0 10. Compressor 10.1 Compressor on and off Control specifications 1.1 When one of the following conditions is met, the compressor stops: 1) Tr ≤ Trt; 2) The compressor runs continuously for more than 3 hours (Stop 5 minutes); 1.2 When all the following conditions are met, the compressor starts up: 1) Tr ≥Trk;...
Service Manual_2020-V1.0 12. Figures and details of repair parts Please log in to TSP system to view and download these contents.
Page 52
MIDEA appliances after sales website tsp.midea.com For more information about Midea appliances after sales, please visit the tsp.midea.com For more information about the service manual, please visit the tsp.midea.com For more information about the EV and SBOM, please visit the...
Need help?
Do you have a question about the HD-332RWEN and is the answer not in the manual?
Questions and answers