Assembly instructions
Installation, commissioning, utilization and maintenance
DE
ACHTUNG! WICHTIGE SICHERHEITSANWEISUNGEN!
Den Hinweisen auf Seite 3 dieser Montageanleitung ist Folge zu
leisten.
GB
ATTENTION! IMPORTANT SAFETY INFORMATION!
Follow the instructions on page 3 of this manual.
FR
ATTENTION! IMPORTANTES INDICATIONS DE SÉCURITÉ!
Les instructions de la page 3 de cette notice de montage doivent
être observées strictement,
NL
LET OP! BELANGRIJKE VEILIGHEIDSINSTRUCTIES!
Volg de instructies op pagina 3 van deze montagehandleiding
op.
IT
ATTENZIONE! INDICAZIONI SULLA SICUREZZA
IMPORTANTI!
Prestare attenzione alle note alla pagina 3 delle presenti
istruzioni di montaggio.
ES
ATENCION INDICACIONES IMPORTANTES DE SEGURIDAD!
Deben seguirse las indicaciones detalladas en página 3 de
estas instrucciones de montaje.
TST FUF2
Versions:
-A / -C / -F
TST FU3F
Versions:
-A / -C / -F
Attention
Important Safety
Information
These instructions must
be observed to ensure
personal safety.
Store these instructions
safely.

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic TST FUF2 Series

  • Page 1 Assembly instructions Installation, commissioning, utilization and maintenance TST FUF2 Versions: -A / -C / -F TST FU3F Versions: -A / -C / -F Attention Important Safety Information These instructions must be observed to ensure ACHTUNG! WICHTIGE SICHERHEITSANWEISUNGEN! personal safety. Den Hinweisen auf Seite 3 dieser Montageanleitung ist Folge zu leisten.
  • Page 2: General Description And Intended Use

    TST RFUxFCOM: interface module for the lock-door applications, etc. TST RFUxIO-B/-E: universale input and ouput extension module Evaluation of interface signals for remote control, diagnosis and configuration of the parameters of the door FEIG ELECTRONIC GmbH page 8 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 3: Intended Use

    1.3.1 Personnel qualification The TST FUF2 or TST FU3F FEIG ELECTRONIC GmbH controller may only be operated and maintained by persons who comply with the requirements outlined here and are familiar with the safety standards of electrical drive and automation technology.
  • Page 4: Safety Information

    A device mark (nameplate with name and address of the manufacturer, serial number, model number, supply voltage and temperature range) must be applied by the user. The example of the warning label must be attached to the motor near the motor terminal board. FEIG ELECTRONIC GmbH page 12 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 5: Installation Of The Controller

    This must be at least 0,02 m3. Should cooling not be sufficient, an additional heat sink may be inserted between the controllers housing and the additional housing to dissipate the heat to the outside. FEIG ELECTRONIC GmbH page 14 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 6: Electrical Connection

    Damaged keypads and Display window must be replaced. To prevent damage to the keypad, do not use pointed objects to operate the keys. The keypad is only designed to be operated by human fingers. FEIG ELECTRONIC GmbH page 24 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 7 The plastic version of the control consists of the mounting frame incl. printed circuit board, which is inserted into the housing. The housing has the following dimensions: 89,5 Figure 4 Dimensions and drilling plan FUxF-xH Plastic housing FEIG ELECTRONIC GmbH page 19 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 8 3.3 Versions in steel or stainless steel housing Steel and stainless steel housing variants are also available. The housing has the following dimensions: 3.3.1 300 x 400 mm T = 200 Figure 5: Housing 300 x 400 FEIG ELECTRONIC GmbH page 20 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 9 Assembly instructions FUF2 / FU3F -A/-C/-F 4.1 Power supply connection 4.1.1 TST FUF2 fuse 16A / K- Type Figure 9: Connecting the power cable FEIG ELECTRONIC GmbH page 26 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 10 Assembly instructions FUF2 / FU3F -A/-C/-F 4.1.2 TST FU3F Fuse 16A / K- Typ Figure 10: Connecting the power cable There is no line choke for TST FU3F-A available. FEIG ELECTRONIC GmbH page 27 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 11 We recommend to place another split ferrite (black, Würth number: 742 717 22 S) around the complete motor cable as close as possible to the door controller. The black split ferrite is not included in the scope of delivery! _13.docx FEIG ELECTRONIC GmbH page 28 of 94 FUxF_Montageanleitung_GB...
  • Page 12 We recommend to place another split ferrite (black, Würth number: 742 717 22 S) around the complete motor cable as close as possible to the door controller. The black split ferrite is not included in the scope of delivery! _13.docx FEIG ELECTRONIC GmbH page 30 of 94 FUxF_Montageanleitung_GB...
  • Page 13 Figure 14: Connection to an optical safety edge If the safety edge type was not automatically detected, the optical safety edge on this input can be activated via parameter P.460 = 5. FEIG ELECTRONIC GmbH page 33 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 14 If the safety edge type was not automatically detected, the resistive safety edge on this input can be activated via parameter P.460 = 1 If no safety edge is connected, automatic closing of the door is not possible. FEIG ELECTRONIC GmbH page 34 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 15 Typically, this input is used as safety input during opening movement. For this example, parameter P.50A = 1406 is set. Then the edge type of parameter P.5A2 must be set = 4. It is important to first set parameter P.50A and then only parameter P.5A2 _13.docx FEIG ELECTRONIC GmbH page 35 of 94 FUxF_Montageanleitung_GB...
  • Page 16 P.5A2 = 3: 8K2 safety edge, N.C. P.5A2 = 6: 1K2 safety edge, N.O. P.5A2 = 7: 1K2 safety edge, N.C. It is important to first set parameter P.50A and then only parameter P.5A2 FEIG ELECTRONIC GmbH page 36 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 17 M8 plug Min. IP65, gold with 4 poles socket plated contacts Wire 3: blue Wire 2: white Wire 4: black Wire 1: brown shield / PE Figure 22: Absolute encoder TST PD _13.docx FEIG ELECTRONIC GmbH page 41 of 94 FUxF_Montageanleitung_GB...
  • Page 18 Terminal 35 Wire 3: GND Terminal 36 Wire 4: Channel A Terminal 34 Wire 5: Emergency stop Terminal 32 Terminal 33 Wire 6: 12 VDC Figure 23: Connection of absolute encoder DES FEIG ELECTRONIC GmbH page 42 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 19 Assembly instructions FUF2 / FU3F -A/-C/-F 4.6.5 Mechanical limit switches Figure 27: Connecting cam switches Alternately, the pre-limit switches can also be connected as normally closed contacts. FEIG ELECTRONIC GmbH page 44 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 20 Assembly instructions FUF2 / FU3F -A/-C/-F 4.7 Photo eye 71 72 73 74 75 76 Receiver Photo eye Figure 28: Photo eye connection _13.docx FEIG ELECTRONIC GmbH page 45 of 94 FUxF_Montageanleitung_GB...
  • Page 21 Figure 29: External triggering devices If an external triggering device is connected, no dead man's drive is possible with the factory parameter setting. This can be activated from parameter level 3: Parameter P.511= 4 and P.531=1. FEIG ELECTRONIC GmbH page 46 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 22 Assembly instructions FUF2 / FU3F -A/-C/-F Traffic light connection L´ L´ N´ N´ 10 1112 20 2122 Bridge blue Figure 30: Traffic light connection FEIG ELECTRONIC GmbH page 47 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 23: Overview Of Outputs

    Figure 31: Overview of outputs Observe maximum voltage and power specifications (see specifications on page 88 Relay outputs Out on page 90)! Different to the standard mentioned here, the function of the outputs is freely selectable. FEIG ELECTRONIC GmbH page 48 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 24: Overview Of Inputs

    Assembly instructions FUF2 / FU3F -A/-C/-F 4.10 Overview of inputs Figure 32: Overview of inputs For the connection of mech. limit switches, please refer to section 4.5.5 Mechanical limit switches. FEIG ELECTRONIC GmbH page 49 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 25 The Induction loop monitor is available in versions TST SUVEK-1 and TST SUVEK-2 Depending on the type, 1 or 2 loops may be monitored. Figure 34: Detector card To activate the slot for the detector, parameter P.802 must be set to 0302 _13.docx FEIG ELECTRONIC GmbH page 51 of 94 FUxF_Montageanleitung_GB...
  • Page 26 Use the arrow keys to select the required parameter. P: Offenhalt 1 010= 10 s Not all the parameters are visible or may be changed immediately; this always depends on the password and the type of position set. FEIG ELECTRONIC GmbH page 58 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 27 Keep the STOP button pressed for approx. 3 seconds in order to leave FEIG ELECTRONIC xxxx the parameter mode and change to the door mode. Zyterminalen 6.4 Execute a reset press simultaneously and keep pressed for approx. 3 seconds. _13.docx FEIG ELECTRONIC GmbH page 59 of 94 FUxF_Montageanleitung_GB...
  • Page 28 The following parameter must be set for 999= 0001 # this: P.999 = 2 (extended commissioning mode) P: Passwort 999= 0001 # P: Passwort 999= 0002?# P: Passwort 999= 0002 # FEIG ELECTRONIC GmbH page 60 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 29: Basic Settings

    Be sure to note the Y/D wiring of the motor. The motor data must be entered in accordance with the motor wiring. For the TST FUF2 the 400V setting is not applicable, since the controller can source a maximum motor voltage of 230V. FEIG ELECTRONIC GmbH page 61 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 30 After start up, the operation of all the safety devices must be checked. The settings are performed in dead man mode, i.e. press and hold the corresponding arrow key in the corresponding direction until the desired position is reached. FEIG ELECTRONIC GmbH page 62 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 31 Zu pos. OK Tor öffnet I.515 Korr. Fahrt Now press , repeat the process until the correction travel has completed. (Display I.510 = OK) I.510 Korrek. OK Tor öffnet Tor schließt FEIG ELECTRONIC GmbH page 63 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 32 To prevent the door from moving unintentionally, adjust the limit switches only when the Emergency-STOP is activated or with the controller turned off! 12. The door may now be operated in automatic mode. FEIG ELECTRONIC GmbH page 64 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 33 You can use diagnostic parameter P.910 = 2 to display the actual motor current. The boost should be set so that the motor current remains as low as possible. FEIG ELECTRONIC GmbH page 67 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 34 The door is moved at the max. travel speed until the pre-limit switch for the limit position OPEN is reached. The door now moves at creep speed until the limit switch OPEN is reached. At this point the door is stopped (ro). FEIG ELECTRONIC GmbH page 68 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 35 The door is moved at the max. travel speed until the pre-limit switch for limit position CLOSE is reached. At this point it The door now moves at creep speed until the limit switch CLOSE is reached. At this point the door is stopped (ru). FEIG ELECTRONIC GmbH page 69 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 36: Ramp Configuration

    Changing in the negative direction causes a shift towards the bottom. 10 Functions You will find an overview of Parameters of this assembly instruction and there description in the added document "Parameter list TST FUxF". FEIG ELECTRONIC GmbH page 70 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 51: General Messages

    Information messages during the parameter configuration noEr Error memory: no error saved Er-- Error memory: if error but without associated message being found Prog Programming message while carrying out original parameter or default set _13.docx FEIG ELECTRONIC GmbH page 85 of 94 FUxF_Montageanleitung_GB...
  • Page 52 Wireless Channel 1 E.402 Wireless Channel 2 Inductive loop detection E.501 Detector channel 1 E.502 Detector channel 2 E.503 Detector channel 3 E.504 Detector channel 4 Internal inputs E.900 Controller chip fault signal FEIG ELECTRONIC GmbH page 86 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 53 Input 2 of mobile unit E.F03 Input 3 of mobile unit E.F04 Input 4 of mobile unit E.F0A Input A of stationary unit E.F0B Input B of stationary unit E.F0C Input C of stationary unit FEIG ELECTRONIC GmbH page 87 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 54: Specifications

    "Control inputs" Digital "IN > 7 V: active logical 1 8, 9 ,11, 12 (Terminal 61, min. Duration of input control commands:> 100 ms 64, 92, 93): Used for 2-channel incremental position encoder FEIG ELECTRONIC GmbH page 88 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 55 - 40 ° C ... + 85 ° C ". Due to the large number of USB sticks available, the functionality of each of these sticks cannot be guaranteed. FEIG ELECTRONIC GmbH recommends the USB sticks listed below: for not logging function: AF8GUFNDNC-AADXX USB-Stick, 8GB, USB 2, MLC, 0°C to 70°C...
  • Page 56 Alternative use as a Changeover contact to enable electromechanical brakes with upstream braking relay brake rectifier. (Out 3 / X16): no safety function. Max. 230 VAC / 3 A (Use secure phase of L') FEIG ELECTRONIC GmbH page 90 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 57 Observe duty cycle and temperature range: Continuous travel with rated current for max. 20 minutes for example 6 seconds drive and 4 seconds break for example 8 seconds drive and 12 seconds break FEIG ELECTRONIC GmbH page 91 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 58 (s. "Drive output") Equipment mobility: Stationary Motor type external motor is not part of the delivery from Equipment type: FEIG ELECTRONIC GMBH IP 65 (only in connection with a plastic housing and with sealed Protection class cable glands). Protection class:...
  • Page 59: Standards And Directives

    Electromagnetic radiation, living area EN 61000-6-4: 2007 / A1:2011 Electromagnetic radiation, industrial area Applied national specifications EN 12453:2000 Safety in use of power operated doors - regarding the above directives: Requirements Supply FEIG ELECTRONIC GmbH page 93 of 94 FUxF_Montageanleitung_GB_13.docx...
  • Page 60 Assembly instructions FUF2 / FU3F -A/-C/-F FEIG ELECTRONIC GmbH page 94 of 94 FUxF_Montageanleitung_GB_13.docx...