EXPANDED STARTUP
TST WU
Important !
You must read the Function Description before operating,
connecting or starting up the door controller.
preliminary
public (B)
2007-05-29
WU_erweiterte_ Inbetriebnahme4_GB.doc

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic TST WU

  • Page 1 EXPANDED STARTUP TST WU Important ! You must read the Function Description before operating, connecting or starting up the door controller. preliminary public (B) 2007-05-29 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 2 FEIG ELECTRONIC GmbH. Starting up the control must be carried out only by officially trained electrical experts who are familiar with the safety standards of electrical drive and automation technology. The entity which has placed the TST WU gate control in service is solely responsible for the completeness of the startup manual.
  • Page 3: Table Of Contents

    The contents of the Startup manual and in particular the safety advisories must be strictly observed. Entering expanded parameterizing mode To enter expanded mode a password must be entered. For this the following parameter must be set: P.999: 2 = expanded startup mode FEIG ELECTRONIC GmbH Page 3 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 4: Optimizing Door Operation

    The door movement starts with an open command, so that the OPEN-contactor will be energized. The door moves as long as the limit switch or the limit switch band for the open position has reached. At this point the OPEN-contactor will be deactivated. FEIG ELECTRONIC GmbH Page 4 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 5: Closing The Door

    The door moves as long as the limit switch or the limit switch band for the close position has reached. At this point the CLOSE-contactor will be deactivated. If an open command is given during closing of the door the door will reverse and open. FEIG ELECTRONIC GmbH Page 5 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 6: New Request For Automatic Limit Switch Calculation

    This is done with the help of output profiles. The output profiles can be used to assign pre-programmable functions to the outputs. Output relays K1 and K2 on the TST WU door controller can be set as well as K3 to K6 when used with TST RWU.
  • Page 7: Maintenance Counter

    2: Only automatic opening and deadman closing are possible and error F.080 is output. 3: Only deadman travel is possible and error F.080 is output This setting is made at the factory and cannot be changed here. FEIG ELECTRONIC GmbH Page 7 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 8: Parameter List

    Correction value for Lower end position ± 125 (set to 0 for new calibration !) [Inc] Correction value for Upper end position ± 60 (set to 0 for new calibration !) FEIG ELECTRONIC GmbH Page 8 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 9 1: Input profiles 0000 ... 1402 Function of input 10 see table 1: Input profiles 0000 ... 1402 Function of input 31 see table 1: Input profiles Only useable with TST SUVEK FEIG ELECTRONIC GmbH Page 9 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 10 0000 ... 1402 Function of input 26 see table 1: Input profiles 0000 ... 1402 Function of input 27 see table 1: Input profiles 0000 ... 1402 Function of input 28 see table 1: Input profiles FEIG ELECTRONIC GmbH Page 10 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 11 2. Upper -> CLOSE -> OPEN N.C. = normally closed, N.O. = normally open OPEN 3 and OPEN 4 cannot be locked out. N.C. = normally closed, N.O. = normally open FEIG ELECTRONIC GmbH Seite 11 von 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 12 0501 Photoeye with 0502 through-travel N.C. as before as before With Both Without Without Photo-eye sensing 1 Min. hold- 0504 Photoeye N.C. as before With Both Without Without Photo-eye open time FEIG ELECTRONIC GmbH Page 12 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 13 Without Without Cross Traffic and DET2 Cross-traffic, 0903 OPEN1+2 and N.O. Without Without Cross Traffic DET1+2 Deactivate hold-open 1001 N.O. Without Without Deacti-vation time 1002 Deactivate airlock N.O. Without Without Deacti-vation FEIG ELECTRONIC GmbH Page 13 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 14 Without Limit Open 1110 Endswitch Close N.C. Without Without Limit Close 1111 1112 Reference switch N.O. Without Without Reference - 1113 Reference switch N.C. Without Without Reference 1114 reserved Without Without FEIG ELECTRONIC GmbH Page 14 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 15 As before With Both Without Without STOP Stop during opening In Door Safety input A 1408 N.C. As before As before With Both Without Without Feed Retent. close Draw in safety position FEIG ELECTRONIC GmbH Page 15 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 16 All red traffic lights type 1 are turned off in the Door CLOSED end position. The exact settings which this profile involves can be found in Appendix: Output Profile FEIG ELECTRONIC GmbH Seite 16 von 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 17 Er-- Ebcl • Ebcl → delete complete failure memory Eb - • Eb - → Cancel (Display noEr: no errors) Display software version Run-time of motor during last door operation 0..120.0 FEIG ELECTRONIC GmbH Page 17 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...
  • Page 18 Reset service counter: Reset (1) / Cancel (0) 0..2 Service mode 0: Au Automatic (opening and closing, self-retaining) 1: Hc Deadman Close (Manual Close, / Automatic Open 2: Hd Deadman (manual Open and Close) 0..FFFF Password entry FEIG ELECTRONIC GmbH Page 18 of 18 WU_erweiterte_ Inbetriebnahme4_GB.doc...