CHECKLIST (1/3)

PRELIMINARY CHECKS

Have you cleaned the system and the boiler (if present)?
Have you checked the water quality?
Where are you installing the units? Make sure that:
• The external unit is installed with the specified clearances from the walls, ceiling and floor.
• The internal unit is installed with the specified clearances from the walls and ceiling.
• The system interface is at least 1.5 m off the floor and not close to sources of heat, draughts and openings to
outdoors.
• The external sensor is mounted on a north facing wall at least 2.5 m off the ground.
e
D
C
c
d
D
a
b
c
[mm]
[mm]
[mm]
ABC
≥150
≥150
≥300
B
≥150
D
BE
≥150
BD
≥150
DE
e
B
E
e
B
b
a
A
d
e
e
e
D
B
[mm]
[mm]
[mm]
[mm]
≥500
≥500
≥150
≥1000
≥1000 ≥1000 ≥1000
a
The external and internal units must be
installed by a qualified technician. For detailed
instructions, refer to the installation manual.
350
mm
200
mm
350
mm
800
mm
EN / 3