Trane 2TEE3C31A1000A Installer's Manual page 4

Convertiblevariable speedcommunicating air handlers 2 112- 5 ton
Hide thumbs Also See for 2TEE3C31A1000A:
Table of Contents

Advertisement

Installer's
Guide
Figure 4
Two-Piece Wrapper Spear Closeup
u
f_
C. UNIT INSTALLATION
UPFLOW
a. For maximum
efficiency,
the horizontal
drip
tray should be removed.
See Figures
5, 6 and 7.
Tray removal
requires
that
the coil be removed
by sliding
the coil out on the coil channel
sup-
ports.
For the TEE3C40-65
units, there
is a coil
support
tab at the top of the coil connected
to the
case that
must be removed
first. Remove
1 inch
insulation
strip covering
the lip of the drip tray.
The tray is detached
by removing
the two screws
at the drain pan. Remove the two screws holding
the two brackets
at the top of the coil. Remove
drip tray by gently breaking
the seal between the
drip tray and drain pan.
b. Remove
the
factory
installed
baffle
assembly
from
the
apex
of the
coil by using
a 5/16"
nutdriver
to remove
the
screws.
Replace
this
baffle with the factory supplied
narrow
coil baffle
using the screws removed
previously.
See Figure
11.
When instalfing
the narrow
coil baffle,
make
sure
to
align the baffle up with the holes so NOT to puncture
the coil tubing.
C.
d.
e.
g.
Position
unit on Pedestal
or other suitable
foun-
dation.
If Pedestal
is not used, a frame
strong
enough
to support
the total weight
must be pro-
vided. Provide a minimum
height
of 14 inches for
proper unrestricted
airflow.
If a return
air duct is connected
to the air han-
dler, it must be the same dimensions
as shown in
the outline drawing
on page 18.
Pedestal
and unit
should
be isolated
from the
foundation
using a suitable
isolating
material.
Openings
where
field
wiring
enters
the
cabinet
must
be completely
sealed.
Location
of power
entry
is shown
on the outline
drawing.
Use
2.5" clear
stickers
to seal
all unused
electri-
cal knockouts.
See Figure
9.
After ductwork
connections
are made,
seal air-
tight and per local codes.
DOWNFLOW
a.
b.
For
maximum
efficiency,
the horizontal
drip
tray should be removed.
See Figures
5, 6 and 7.
Tray removal
requires
that
the coil be removed
by sliding
the coil out on the coil channel
sup-
ports. For the TEE3C40-65
units, there
is a coil
support
tab at the top of the coil connected
to the
case must be removed
first. Remove
1 inch insu-
lation
strip covering
the lip of the drip pan. The
tray is detached
by removing
the two screws
at
the drain pan and the two screws holding the two
brackets
at the top of the coil. Remove drip tray
by gently breaking
the seal between
the drip tray
and drain pan.
Remove
the
factory
installed
baffle
assembly
from
the
apex
of the
coil by using
a 5/16"
nutdriver
to remove
the
screws.
Replace
this
baffle with the factory supplied
narrow
coil baffle
using the screws removed
previously.
See Figure
11. Reinstall
coil assembly.
When installing
the narrow
coil baffle,
make
sure to
align the baffle up with the holes so NOT to puncture
the coil tubing.
NOTE:
Installation
of the downflow
baffle
kit included
with unit is required
on downflow
applications.
See
Figure
10.
c. Remove
the front shield
from the coil. See Fig.
10.
d. Detach the coil from the drain pan by removing
4
screws as shown in Figure
10.
4