Trane 4TEE3C49A1000A Service Facts
Trane 4TEE3C49A1000A Service Facts

Trane 4TEE3C49A1000A Service Facts

Convertible variable speed communicating air handlers
Hide thumbs Also See for 4TEE3C49A1000A:

Advertisement

Quick Links

Service Facts
Convertible Variable Speed –
Communicating Air Handlers
2/4TEE3C49A1000A
WARNING:
PRODUCT SPECIFICATIONS
MODEL
RATED VOLTS/PH/HZ.
RATINGS 1
INDOOR COIL — Type
Rows — F.P.I.
Face Area (sq. ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.) 2
DUCT CONNECTIONS
INDOOR FAN — Type
Diameter-Width (In.)
No. Used
Drive - No. Speeds
CFM vs. in. w.g.
No. Motors — H.P.
Motor Speed R.P.M.
Volts/Ph/Hz
F.L. Amps
FILTER
Vertical Applications
Filter Furnished?
Type Recommended
No.-Size-Thickness
Horizontal Applications
Filter Furnished?
Recommended Size
REFRIGERANT
Ref. Line Connections
Coupling or Conn. Size — in. Gas
Coupling or Conn. Size — in. Liq.
DIMENSIONS
Crated (In.)
Uncrated
WEIGHT
Shipping (Lbs.) / Net (Lbs.)
1 These Air Handlers are A.R.I. certified with various Split System Air Condi-
tioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split Sys-
tem Outdoor Unit Product Data Guides for performance data.
2 3/4" Male Plastic Pipe (Ref.: ASTM 1785-76)
3 Minimum filter size for horizontal applications will be based on airflow selec-
tion and will be calculated as follows:
Low Velocity Filter: Face area (Sq. Ft.) = CFM / 300
High Velocity Filter: Face area (Sq. Ft.) = CFM / 500
4 Torque Spec for TXV = Tighten 1/6 turn past finger tight
5 See Installer's Guide for drawings
6 For customer ease of filter maintenance, it is recommended that a properly
sized, remote filter and grille be installed for horizontal applications. Airflow
should not exceed the face value of the filter being used. The factory in-
stalled filter should then be removed from the unit.
© Trane 2008
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
2/4TEE3C49A1000A
200-230/1/60
See O.D. Specifications
Plate Fin
4 — 14.0
6.19
3/8 - Copper
TXV - Non-Bleed 4
3/4 NPT
See Outline Drawing 5
Centrifugal
10 x 10
1
Direct - Serial ECM
See Fan Performance Table
1 — 3/4
Variable
200-230/1/60
6.8
Yes
Low Velocity
1 - 20 X 25 - 1 in.
See Note 6
See Note 3
R-22
R-410A
Brazed
Brazed
1-1/8
7/8
3/8
3/8
H x W x D
59-1/2 x 28-1/2 x 23-1/2
57-7/8 x 26 x 21
188 / 173
IMPORTANT — This document contains a wiring diagram
and service information. This is customer property and is
to remain with this unit. Please return to service information
pack upon completion of work.
AIRFLOW ADJUSTMENT
If the airflow needs to be increased or decreased, see
the Airflow Label on the air handler or the Blower Per-
formance table in these Service Facts. Information on
changing the speed of the blower motor for your specific
outdoor model size is in the Blower Performance Table
or User Interface Menu.
Blower speed changes are made with the User Interface
Menu mounted in the control box.
WARNING
!
THIS INFORMATION IS INTENDED FOR USE BY INDI-
VIDUALS POSSESSING ADEQUATE BACKGROUNDS
OF ELECTRICAL AND MECHANICAL EXPERIENCE.
ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDI-
TIONING PRODUCT MAY RESULT IN PERSONAL IN-
JURY AND OR PROPERTY DAMAGE. The manufacturer
or seller cannot be responsible for the interpretation of
this information, nor can it assume any liability in con-
nection with its use.
CAUTION
!
RECONNECT ALL GROUNDING DEVICES.
All parts of this product that are capable of conducting
electrical current are grounded.
screws, straps, clips, nuts, or washers used to com-
plete a path to ground are removed for service, they
must be returned to their original position and prop-
erly fastened.
TEE3C49A-SF-1B
If grounding wires,
TEE3C49A-SF-1B

Advertisement

loading

Summary of Contents for Trane 4TEE3C49A1000A

  • Page 1 TEE3C49A-SF-1B © Trane 2008...
  • Page 2 Airflow Performance 2/4TEE3C49A1: with Wet coil, No Heaters, Filter Airflow Settings EXTERNAL STATIC PRESSURE (in.w.g.) Outdoor Airflow Unit Size Power Name CFM/ton Watts Med-Lo 1029 1045 1053 1051 1042 Watts tons Med-Hi 1177 1191 1198 1196 1187 Watts High 1326 1334 1335 1337...
  • Page 3: Unit Test Mode

    NOTES: *** = 000, BRK or PDC - 000 = pigtails, BRK = contains circuit breakers & PDC = contains pull disconnect. IMPORTANT: Any power supply and / or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical codes MIN BLOWER SPEED CAPACITY WITH OUT...
  • Page 4 2/4TEE3C49A USER INTERFACE MENU TEE3C49A-SF-1B...
  • Page 5: User Interface

    2/4TEE3C49A USER INTERFACE MENU- 24V MODE USER INTERFACE Push left & right to scroll through menu options Viewing Window Push up & down to scroll through ENTER setup menu Push ENTER to make selection User Interface pictured above adjusts variable speed airflow options. TEE3C49A-SF-1B...
  • Page 6 AIR HANDLER FLASH CODES Alert Notification Alert Comfort Alert Group Alert Description User Interface Code Fault LED COMM LED Control Display Display Solid ON ‡ CNTRL FAULT † ERR 18 Control Failure Internal Control Error Solid ON ‡ CHECK FUSE † N/A + Fuse Failure 24V Fuse Open Error...
  • Page 7 WIRING DIAGRAM FOR 2/4TEE3C49A TEE3C49A-SF-1B...
  • Page 8 OUTLINE DRAWING FOR 2/4TEE3C49A Printed from Dwg. D802101 Rev. 3 Trane 6200 Troup Highway Tyler, TX 75707 1/08 Since the manufacturer has a policy of continuous product and product data improvement, it reserves the For more information contact your local dealer (distributor)

This manual is also suitable for:

2tee3c49a1000a