Dynapac Compaction Indicator (Dci) - Fayat Group DYNAPAC DRP40DX Manual

Reversible plate
Table of Contents

Advertisement

Operation – Dynapac Compaction Indicator (DCI)

6.5 Dynapac Compaction Indicator (DCI)

Start process
Measuring operation
6
5
4
3
2
1
Fig. 54
Comparability of measuring values
60
The DCI informs the driver about the compaction status of the sub-
structure and enables the detection and selected re-compaction of
weak spots.
An acceleration sensor on the base plate measures the reaction of
the subsoil to the base plate of the machine.
The DCI is automatically started by switching the ignition on.
The DCI first of all runs an LED test. The LEDs light up one after
the other, starting with LED (1). Once all LEDs are on, the display
goes out again in single steps.
With the vibration switched on, the measuring value is displayed by
the LED display (1-10).
If the display value does not increase any further, no further com-
7
paction can be achieved with this machine.
8
The maximum display value (LED display 1-10 and
9
warning display a) is not always reached.
10
a
B-DIS-1054
The warning display (a):
n
n
n
In order to achieve the desired compaction condition of the sub-
structure, one must always perform a suitable reference measure-
ment before compaction is started.
The reference measurement is used to determine which display
value of the DCI corresponds with the measuring value for soil
stiffness.
Due to fluctuations in the measuring value, the dis-
play value can vary by one digit up/down during a
pass.
The average display value during the last pass is
decisive.
Flashes for approx. 1 - 2 seconds after the vibration has been
switched on. The display goes out as soon as the vibration
frequency has been reached.
Flashes if the vibration frequency is too low.
Lights up, when at the same time the LED displays (1 - 10)
have gone out, if no vibration has been detected.
DRP40DX

Advertisement

Table of Contents
loading

Table of Contents