Dci Faults - Fayat Group DYNAPAC DRP40DX Manual

Reversible plate
Table of Contents

Advertisement

9.8 DCI faults

6
5
4
3
2
1
Fig. 136
Fault
LED (a) flashes
LED (a) lights up
The displayed
measuring values
are not plausible
7
8
9
10
a
B-DIS-1054
Possible cause
Switching on: The LED (a) flashes for
approx 1 - 2 seconds after the vibration
has been switched on.
Vibration frequency too low
No vibration detected
Acceleration sensor is not connected.
Cable breakage
The acceleration sensor is not fastened
correctly.
Weak spots in the sub-base
Troubleshooting – DCI faults
Remedy
Start the engine, set the throttle lever to
position "MAX" (switch vibration on).
Check the connection of the acceleration
sensor.
Check the connection of the acceleration
sensor.
Inform our Customer Service Department
Shut down the engine and check the fas-
tening screws of the acceleration sensor.
In unfavourable cases, an excessively
varying material composition or moisture
in the sub-base can influence the meas-
uring results.
On material which is too dry or moist,
lower measuring values will be displayed.
DRP40DX
113

Advertisement

Table of Contents
loading