Blackmagicdesign URSA Broadcast G2 Installation And Operation Manual page 206

Table of Contents

Advertisement

Attaching the PL Mount
1
Gently insert the PL baffle into the center of the lens
mount and turn until it is finger tight. Use the wide
end of the baffle tool to tighten the baffle slightly.
You need just enough pressure to keep it in place.
3
Loosely turn the five mounting screws until initial
contact is made with the shoulder of the lens
mount. To access all five screws, you will need to
rotate the PL locking ring, as some holes are
obscured when the ring is either open or closed.
NOTE When removing the PL mount, simply follow the instructions in reverse order
from step 4 to step 1. Don't forget to remove the PL baffle and store it securely with the
PL mount.
To attach a PL mount lens:
1
Open your camera's PL locking ring by rotating it counterclockwise until it stops.
2
Align one of the lens' four flange notches with the locating pin on the camera mount.
Be sure to align the lens for easy viewing of the lens marks.
3
Tighten the PL locking ring by rotating it clockwise. If attaching a PL lens with a servo unit to
URSA Broadcast G2, you can also connect the 12 pin broadcast connector for servo control.
2
Ensure the pins on the PL mount for
Cooke /i Technology are located at the
12 o'clock position.
4
1
4
5
Using the 2mm Hex driver, or torque wrench with
2mm Hex key, apply one full turn of pressure to
mounting screw 1, followed by one full turn to
screw 2. Repeat for screws 3 and 4, then 5.
Continue to apply one full turn to each screw in
the sequence above until all screws have reached
the maximum torque of 0.45Nm.
Interchangeable Lens Mount
3
2
206

Advertisement

Table of Contents
loading