<3> Connect the exchange adapter and emulation probe to the target connector.
<4> Connect the GND wires on the target system side of the emulation probe to the target system
GND. If a pin or screw is fastened to the target system GND, remove the transparent terminal
cover on the end of the GND wire and fasten the Y terminal of the GND wire to the target system
(C in Figure 2-8). If the GND on the target system is an exposed pad, likewise fasten the Y
terminal to the pad on the target system by soldering (recommended soldering iron temperature
setting: 300°C).
<5> Since the length of the GND wire below the head (insulated part) is approximately 60 mm, there
must be a GND to which it can be connected to within the range of the two approximately 60 mm
radius sections of the target system for connecting the emulation probe, as shown in Figure 2-9.
R20UT2080EJ0100 Rev.1.00
2013.03.18
Figure 2-9 Where GND Wire Can Be Connected
CHAPTER 2 SETUP PROCEDURE