15) Maintenance, Overhaul and Repair
Maintenance, repair and overhaul of the equipment should
only be carried out by suitably qualified personnel in
accordance with the current relevant standards:
EN60079-19/IEC60079-19
Explosive atmospheres – Equipment repair, overhaul and
reclamatio
EN 60079-17/IEC60079-17
Explosive atmospheres – Electrical installations inspection
and maintenance
Units must not be opened while an explosive atmosphere is
present.
If opening the unit during maintenance operations a clean
environment must be maintained and any dust layer removed
prior to opening the unit.
Flameproof threaded joints and cemented joints are not
permitted to be repaired.
Electrostatic charging hazard - Clean only with a damp cloth.