Medela Solo Hands-free Instructions For Use Manual

Medela Solo Hands-free Instructions For Use Manual

Electric breast pump
Hide thumbs Also See for Solo Hands-free:

Advertisement

Solo
Hands-free
Content appearance may vary from pictures.
¢ 1
1-01-1
1-01-4
1-01-2
1-01-5
1-01-6
¢ 3
3
3-01
3-01-1
¢ 4
3
4-02
or
4-01
¢ 5
10 min
5-01
1-01
1-01-3
1-01-7
1-01-8
1-02-1
1-03
3-02
or
5-02
Electric breast pump
Instructions for use
1-02
1-04
1-02-2
¢ 6
6-01
4-03
5-03
6-02
ENGLISH
EN Fold these pages out.
¢ 2
2-02
17 mm
20 mm
23 mm
Ø
Ø
Ø
21
24
27
mm
mm
mm
3-21
2-01
2-03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Solo Hands-free and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Medela Solo Hands-free

  • Page 1 Solo Hands-free ™ ENGLISH Electric breast pump Instructions for use 3-21 EN Fold these pages out. Content appearance may vary from pictures. ¢ 1 ¢ 2 2-01 1-02 1-01 1-04 1-01-3 1-01-7 1-01-8 1-02-2 1-02-1 1-01-1 1-01-4 1-03 1-01-2 1-01-5 1-01-6 2-02 2-03...
  • Page 2 ¢ 7 ¢ 9 9-01 3. Make sure 7-01 7-02 Orioles and y Ensure that th the breast shi 9-02 7-03 7-04 7-07 7-05 7-06 9-03 ¢ 8 9-04 ¢ 10 ¢ 11 11-01 11-02 11-03 11-04 solo solo solo ¢...
  • Page 3: Important Safety Information

    If damage is found, immediately discontinue use Virus (HIV), pumping breast milk will not reduce or remove the risk of of power adapter and call Medela Customer Service. transmitting the virus to your baby through your breast milk.
  • Page 4 • Do not place or store the product where it can fall into water. • Only use Medela recommended parts with your breast pump. • The breast pump and accessories are not heat-resistant. Keep away •...
  • Page 5: Table Of Contents

    Contents Important safety information 12. Troubleshooting Intended purpose 13. Ordering information Product description 14. Warranty Getting started 15. Disposal Cleaning before first use 16. Meaning of symbols Charging the battery 17. International regulations Disassembling your collection cup 17.1 Electromagnetic compatibility (EMC) Cleaning 18.
  • Page 6: Intended Purpose

    For ordering information about accessories see chapter 13. All pictures shown in these instructions are for illustration purpose only. The actual product may vary due to local differences or product enhancement. Medela reserves the right to substitute any component or accessory with a replacement of equivalent performance.
  • Page 7: Getting Started

    Information Only use power adapter and cable that comes with the breast pump. • The warranty is only valid when using the Medela power adapter to charge your pump (Model MS-V2000U050-010B0-*). An inadequate power source or cable may result in a fire hazard, •...
  • Page 8: Cleaning Overview

    6.1 Cleaning overview Washing and sanitising are two different activities. They must be done separately to protect you and your baby, and to maintain the performance of your breast pump. Wash – To clean the surfaces of the parts by physically removing milk residues and other possible contaminants. Sanitise –...
  • Page 9: Washing

    NOTICE The Solo Hands-free breast pump has a closed system ™ • Take care not to damage parts of the collection cup during cleaning. so milk cannot get into the tube when the pump is used • Store the dry collection cup in a clean bag/container until next use. as instructed.
  • Page 10: Sanitising

    6.3 Sanitising Refer to figure ¢5 on the foldout pages. Sanitise on stovetop Sanitise in microwave (before first use and once per day after use) (once per day after use) 10 min 1. Cover the disassembled, washed parts, except for the tubing, 1.
  • Page 11: Assembling Your Breast Pump

    2. Place the collection cup in your bra according to chapter 7.4. • Always inspect all parts prior to use for cleanliness. If dirty, clean Start pumping as described in chapter 9. according to chapter 6. • Only use genuine Medela parts. See chapter 13 for details.
  • Page 12: Placing Collection Cup Within Your Bra

    7.4 Placing collection cup within your bra Refer to figure ¢9 on the foldout pages. preference. Ensure that the tubing is not pinched or bent during use. 1. ¢9-01 Ensure that the nipple is centered in the tunnel of the breast Æ...
  • Page 13: Bluetooth ® Connectivity

    Trademark recognition: The Bluetooth word mark and logos are registered the following steps: trademarks owned by Bluetooth SIG, Inc., and any use of such marks by Medela 3. Press and hold the Let-down button for two seconds to start the AG is under license.
  • Page 14: Expressing Your Breast Milk

    1 level with the Decrease vacuum button. restarting with stimulation phase. 6. When your pumping session is over, press the On/Pause/Off button • Do not forget to record milk output in the Medela Family ™ app. to stop the pumping operation.
  • Page 15: Handling Of Breast Milk

    • Store breast milk in the coldest spot of the refrigerator (at the back of Gently swirl the bottle or bag to mix any fat that has separated. Avoid the glass shelf above the vegetable compartment). shaking or stirring the milk. • For information on storing your breast milk, visit www.medela.com.
  • Page 16: Maintenance And Care

    If the power adapter outer casings become loose or are separating, • For optimum pump and battery performance use the power adapter stop use and contact Medela immediately. Separation of the casing can that comes with the breast pump (Model MS-V2000U050-010B0-*).
  • Page 17: Troubleshooting

    • If the pump is still not working contact around the breast. Medela Customer Service. • If suction does not improve after • Contact Medela Customer Service. The breast pump generates having followed these steps, contact only constant vacuum instead Medela Customer Service.
  • Page 18: Ordering Information

    If you have not resolved the problem with your breast pump or you have For contact data visit www.medela.com/contact-us. Under “Contact” further questions, please contact Medela Customer Service. For contact choose your country. For replacement of lost or defective parts please data visit www.medela.com/contact-us.
  • Page 19: Meaning Of Symbols

    Breast shield, outer shell, tubing and membrane The parts are made of plastics that are not harmful to the environment when disposed of as household waste. Recycle or dispose of according to local regulations. Motor unit and power adapter Do not dispose of electric or electronic equipment together with unsorted municipal waste, but collect it separately. In the European Union the manufacturer or its vendor must take back waste equipment.
  • Page 20: International Regulations

    Indicates the polarity of the USB Indicates that the device is a Class II Indicates that the device is for indoor power output. electrical appliance (double insulated). use only. 4pin-/1pin+ Indicates that a specific separate power adapter is required for Indicates that the appliance is Indicates that the power supply unit connecting the device to the supply...
  • Page 21: Technical Specifications

    18. Technical specifications Summary of important technical specifications Operating temperature range +35ºC (5 °C to 35 °C) Vacuum performance (at 500 m above sea level [954.62 hPa ambient pressure]) (41 °F to 95 °F) -45 to -245 mmHg (-60 to -327 hPa) 45 to 111 cpm Operating humidity range (15% to 93% relative humidity) Power adapter (Model: MS-V2000U050-010B0-*)