AXIS F9114 Main Unit
Specifications
Important
To avoid unwanted shutdown, only turn on Delayed shutdown when the ignition is physically connected to the main unit.
Note
If the device has been without power before it is turned on, a delay occurs before Delayed shutdown is activated.
1. Connect to ignition control on the 3-pin terminal block.
2. Go to the device's webpage.
3. Go to System > Power settings and turn on Delayed shutdown.
4. Set a delay time between 1 and 60 minutes.
RS232/RS485 connector
5-pin terminal block for the RS232/RS485 serial interface used to control auxiliary equipment. In order to use the RS232/RS485 port
you need a third-party application for AXIS Camera Application Platform. The port can be used in the following modes:
2TX/2RX RS232 interface (TXD, RTS, GND, CTS, RXD)
Bidirectional RS485 half-duplex port for data transmission using two wires, one combined RX/TX pair.
Bidirectional RS485 full-duplex port for data transmission using four wires, one RX pair and one TX pair.
Function
RS232 TXD alt
RS485 TX-
RS232 RTS alt
RS485 TX+
RS232 GND alt
RS485 GND
RS232 CTS alt
RS485 RX-
RS232 RXD alt
RS485 RX+
FAKRA connector
The FAKRA connector is used for connecting the sensor unit to the main unit.
For information on how to shorten the sensor unit cable see Shorten the sensor unit cable on page 3 .
Pin
Notes
1
RS232 driver output
4-wire RS485 (combined RX/TX pair for 2-wire RS485)
2
3
Ground
4
RS232 receiver input
4-wire RS485 (not used for 2-wire RS485)
5