LG FH6G1BAPK2 Service Manual page 19

Table of Contents

Advertisement

5-3. Check program mode
■ Enter the LQC mode.
■ Press the [Start] button; the product operates as follows each time it is pressed:
☞ The 5th operation starts when the motor comes to a complete stop, and the sixth operation proceeds upon
pressing after the motor is stopped.
Start button
Step
Press count
No.
0
0
1
1
2
6
3
7
4
9
5
11
6
12
7
13
8
14
9
15
10
16
11
2
12
3
13
4
14
22
15
18
1. Press 15 times in the 7 o'clock direction.
2. Screen changed to LQC mode.
Step
Display version
Tub turning CW
Cold Valve
Hot Valve
Atomizing Valve
Dry Filter Clean Valve
Eva Valve
Tub turning CCW
Wash heater activated
Circulating pump activated
Drain pump activated
Low speed spin
High speed spin
Automatic detergent/
Softener pump activated
Flow Meter
(Fan Motor/Compressor/Cooling
Fan)HeatPump
Display
1. Initial letter
2. Main ver.
3. Display ver.
4. Heat Pump ver.
Check RPM
/ Visual inspection
Water Level
Water level
Water level
Water level
Water level
RPM
Temperature
Water level
Water level
RPM
RPM
Water level
FlowMeter Pulse
1. Comp Freq.
2. Eva InTemp.
3. Eva Out Temp.
4. Comp Out Temp.
5. Fan Motor RPM.
19
Output check
Version check
CW 46RPM
Check FlowMeter pulse
Check water level
Check water level
Check water level
Check water level
CCW 46RPM
Check temperature
On
On
600RPM
Max RPM
Zig. Inspection
(Heat Pump On)
Zig. Inspection
(Heat Pump On)
Zig. Inspection

Advertisement

Table of Contents
loading

Table of Contents