Gxv3651 Alarm Event - Grandstream Networks GXV3651 Series User Manual

Hide thumbs Also See for GXV3651 Series:
Table of Contents

Advertisement

2. Click Advanced Settings > PTZ; in PTZ page, configure the PTZ Protocol and
Baudrate according to your connected PTZ device.
3. Click Save and reboot the device to apply all changes.
4. Use those PTZ buttons on the homepage to tilt, pan the GXV3651 and also adjust the
speed.
GXV3651 itself does not support PTZ. The users can connect a PTZ device to the
NOTE:
GXV3651 via RS485 pins to pan, tilt and speed.
The FOCUS function may not work as many dome cameras support auto focus.
Press and hold the corresponding control button to adjust the pan, tilt, and speed.

GXV3651 Alarm Event

The GXV3651 supports alarm inputs, for example, infrared detector, smoke detector and so
on.
Follow the steps to make Alarm Input work:
1. Connect alarm input equipment to the GXV3651.
2. Set up the alarm event time schedule.
3. Configure the alarm actions which you would like the GXV3651 to take when alarm is
triggered.
How Alarm Input and Alarm Output Work
Alarm-in is the alarm input port; users are able to connect sensors such as infrared sensor,
smoke sensor or light sensor to it. The detectable signal voltage range for alarm-in is from
1.8V to 15 V
NOTE:
than 15V, this will damage the IP camera.
Internally, the Alarm-out uses relays as a switch (30VAC/2A); users can connect devices such
as alarm siren or alert light to this port. Under normal circumstances, the circuit is open.
When there is an alarm event, the GXV3651 will close the circuit to trigger the alarm.
Connect Alarm Input Equipment to the GXV3651
Here are two sample connection diagrams. Connect the alarm equipment to the GXV3651 by
following the diagram below.
Firmware 1.0.4.6
Grandstream Networks, Inc. 09/2010
Please do not connect a device that has a signal voltage that is higher
GXV3651 IP Camera
Page 25 of 35