AXIS Q6045-S Mk II PTZ Dome Network Camera
About events
The recording Duration of some actions can be set to include time immediately before and after the event. Select Pre-trigger time
and/or Post-trigger time and enter the number of seconds. When While the rule is active is enabled and the action is triggered
again during the post-trigger time, the recording time will be extended with another post-trigger time period.
For more information, see the online help
About triggers
Available action rule triggers and conditions include:
Applications – Use installed applications to trigger the rule. See About applications on page 38.
Detectors
-
Live Stream Accessed – Trigger the rule when any stream is accessed and during edge storage playback.
This can for example be used to send notifications.
-
Motion Detection – Trigger the rule when motion is detected. See About motion detection on page 33.
-
Shock Detection – Trigger the rule when the Axis product detects it has been tilted or hit. See About shock
detection on page 33.
-
Enter/Exit – Trigger the rule when an object has entered or exited the area. See Enter/Exit Detector on page 35.
-
Fence Detector – Trigger the rule when an object has crossed a virtual line. See Fence Detector on page 36
-
Object Removed – Trigger the rule when an object has been removed from a scene. See Object Removed
on page 34.
Hardware
-
Heater – Trigger the rule if the heater is malfunctioning. This can for example be used to send maintenance
notifications.
-
Network – Trigger the rule if network connection is lost or restored. This can for example be used to start
recording to the SD card.
-
Temperature – Trigger the rule if the temperature falls outside or inside the operating range of the product. This
can for example be used to send maintenance notifications.
Input Signal
-
Digital Input Port – Trigger the rule when an I/O port receives a signal from a connected device. See I/O
Ports on page 57.
-
Manual Trigger – Trigger the rule using the Manual Trigger button in the Live View page. See About the
controls in the live view window on page 11 . This can for example be used to validate actions during product
installation and configuration.
-
Virtual Inputs – can be used by a VMS (Video Management System) to trigger actions. Virtual inputs can, for
example, be connected to buttons in the VMS user interface.
PTZ
-
Autotracking – Trigger the rule when autotracking starts or stops. See Autotracking on page 28.
-
Error – Trigger the rule if the PTZ functionality is not working correctly. This can for example be used to
send maintenance notifications.
-
Moving – Trigger the rule when the camera view moves due to a PTZ operation. This can for example be used
as an additional condition to prevent an action rule triggered by motion detection to record video while the
camera view moves due to a PTZ operation.
.