2
Connecting via access point and manual configuration of the WLAN settings
1
2
3
4
NOTE!
Desired network not listed.
If the desired WLAN network is not listed, end access point mode by pressing the button
again and repeat the process.
5
NOTE!
WLAN network scan not possible.
When the access point is opened, it is not possible to scan the WLAN networks.
A static IP address can be assigned to the Ohmpilot via the web interface.
106
Press the WPS button on the router within 2 minutes.
If the blue LED on the Ohmpilot lights up permanently, the connection to the network
was successful.
The inverter automatically searches for the Ohmpilot, and the search process can
take up to 5 minutes. If the red LED is not lit and the green LED is flashing, the Ohm-
pilot is working correctly.
Press the button on the Ohmpilot 2x.
The blue LED flashes (once) as long as the WLAN access point is active (30 minu-
tes). Before the access point is opened, it searches for available WLAN networks.
Activate the "Ohmpilot" WLAN network on your smart device or PC.
In the browser, enter the website http://192.168.250.181 or http://ohmpilotW.local.
Alternatively, the Ohmpilot can also be searched on the network using the Fronius
Solar.web app.
Select the desired network in the WLAN network tab.
Click on "Save & Connect", enter WLAN password.
If the blue LED on the Ohmpilot lights up permanently, the connection to the network
was successful.
The inverter automatically searches for the Ohmpilot, and the search process can
take up to 5 minutes. If the red LED is not lit and the green LED is flashing, the Ohm-
pilot is working correctly.