REGULATION OF AIR SUPPLY TO
OVEN BURNER
Using a cross-head screwdriver, slacken
the screw "Q" securing the air flow
regulation collar "P" (fig. 2.8) and turn the
collar forward or backward to increase
or reduce the air aperture in accordance
with gas type and the indications in the
'Table for the choice of the injectors'.
Light the burner and check the flames.