USER MANUAL ENGLISH NRG-15SA Product code: D3658 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
Page 2
NRG-15SA Preface Thank you for purchasing this DAP product. The purpose of this user manual is to provide instructions for the correct and safe use of this product. Keep the user manual for future reference as it is an integral part of the product. The user manual shall be stored at an easily accessible location.
NRG-15SA Table of contents Introduction ..............................3 Before Using the Product ..........................3 Intended Use ............................... 3 Text Conventions ..............................3 Symbols and Signal Words ..........................4 Symbols on the Information Label ........................4 Safety................................5 Warnings and Safety Instructions ........................5 Requirements for the User ..........................
NRG-15SA Introduction Before Using the Product Important Read and follow the instructions in this user manual before installing, operating or servicing this product. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual. After unpacking, examine the contents of the box.
NRG-15SA Symbols and Signal Words Safety notes and warnings are indicated throughout the user manual by safety signs. Always follow the instructions provided in this user manual. Indicates an imminently hazardous situation which, if not avoided, will result in DANGER death or serious injury.
NRG-15SA Safety Important Read and follow the instructions in this user manual before installing, operating or servicing this product. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual. Warnings and Safety Instructions DANGER Danger for children For adult use only.
Page 7
NRG-15SA Attention Power supply ● Before connecting the device to the power supply, make sure that the current, voltage and frequency match the input voltage, current and frequency specified on the information label on the device. ● Make sure that the cross-sectional area of the extension cords and power cables is sufficient for the required power consumption of the device.
NRG-15SA Attention Do not expose the device to conditions that exceed the rated IP class conditions. This device is IP20 rated. IP (Ingress Protection) 20 class provides protection against solid objects greater than 12 mm, such as fingers, and no protection against harmful ingress of water. Requirements for the User This product may be used by ordinary persons.
NRG-15SA Description of the Device The DAP NRG-15SA is an active subwoofer with a peak power of 1000 W (500 W continuous RMS). It has a 15 " woofer with a dual 3 " voice coil. The device has an internal DSP with 4 modes and a reverse phase switch.
NRG-15SA Back View 04) DSP button and selector with LED indicators 05) Sub filter frequency control 06) Sub phase switch 07) Status LED indicators 08) Sub master gain control 09) 3-pin XLR connector THRU B 10) 3-pin XLR connector THRU A (mono) 11) Power switch (on/off) 12) Power Pro connector OUT (White) 13) Power Pro connector IN (Blue)
NRG-15SA Product Specifications Model: DAP NRG-15SA Physical: Dimensions: 430 x 590 x 520 mm (W x H x D) Weight: 25,5 kg Outputs: RMS output power amplifier: 500 W Peak output power amplifier: 1000 W Main outputs: Audio Specifications: THD level: <...
NRG-15SA Installation and Setup Warnings and Precautions Attention Connect all cables before supplying power. Disconnect power supply before connecting or disconnecting cables. Attention Heavy object This device is heavy. When handling, use a two-person lift to prevent injury. Installation Site Requirements ●...
NRG-15SA Setup with an Audio Mixer You can use the NRG-15SA in a setup with an audio mixer. In this setup you can connect 1 or 2 active subwoofers NRG-15SA to 2 active full-range speakers (NRG-8A/10A/12A/15A). To complete the setup, follow the steps below: Make sure that all devices are switched off.
NRG-15SA Setup with 2 Active Subwoofers To connect 2 active subwoofers to 2 active full-range speakers (NRG-8A/10A/12A/15A), follow the steps below: Use a 3-pin XLR cable to connect the 1 active full-range speaker to the 3-pin XLR connector THRU A (10) of the 1 active subwoofer.
NRG-15SA Setup with 1 Active Subwoofer To connect 1 subwoofer to 2 full-range speakers (NRG-8A/10A/12A/15A), follow the steps below: Use a 3-pin XLR cable to connect the 1 active full-range speaker to the 3-pin XLR connector THRU A (10) of the active subwoofer. Use a 3-pin XLR cable to connect the 2 active full-range speaker to the 3-pin XLR connector THRU B (09) of the active subwoofer.
NRG-15SA Setup without an Audio Mixer You can use the NRG-15SA in a setup without an audio mixer and connect it to an active full-range speaker from the NRG range (NRG-8A/10A/12A/15A). In this setup the active full-range speaker functions as a mixer, combining all input signals. To complete the setup, follow the steps below: Make sure that all devices are switched off.
NRG-15SA Connecting to Power Supply DANGER Electric shock caused by short-circuit The device accepts AC mains power at 100–240 V and 50/60 Hz. Do not supply power at any other voltage or frequency to the device. This device falls under IEC protection class I. Make sure that the device is always electrically connected to the ground (earth).
NRG-15SA Operation Safety Instructions for Operation Attention This device must be used only for the purposes it is designed for. This device is designed to be used as an active subwoofer. It is suitable only for indoor use. Any other use, not mentioned under intended use, is regarded as non-intended and incorrect use. Switching On/Off The device has a power switch.
NRG-15SA Adjusting the Phase The device has a phase switch. You can reverse the phase if the bass response is too weak. Slide the sub phase switch (06) up/down to choose one of the 2 options: ● 0°: normal phase – the subwoofer and the main speakers are in phase, which creates a strong bass response ●...
NRG-15SA Maintenance Safety Instructions for Maintenance DANGER Electric shock caused by dangerous voltage inside Disconnect power supply before servicing or cleaning. Preventive Maintenance Attention Before each use, examine the device visually for any defects. Make sure that: ● There are no deformations on the housing. ●...
NRG-15SA Deinstallation, Transportation and Storage Instructions for Deinstallation WARNING Incorrect deinstallation can cause serious injuries and damage of property. ● Disconnect power supply before deinstallation. ● Always observe the national and site-specific regulations during deinstallation of the device. ● Wear personal protective equipment in compliance with the national and site-specific regulations. Instructions for Transportation ●...