Summary of Contents for Dimplex LA 1422C
Page 1
Glen Dimplex Deutschland Dimplex LA 1422C Installation and Operating Instruction Air-to-Water Heat Pump for Outdoor Installation Order no.: 452170.66.02-EN EN · FD 0305...
LA 1422C English Table of contents Safety notes..............................EN-2 1.1 Symbols and markings ..............................EN-2 1.2 General safety notes ...............................EN-2 1.3 Intended use..................................EN-3 1.4 Legal regulations and directives ..........................EN-3 1.5 Energy-efficient use of the heat pump........................EN-3 Intended use of the heat pump .......................EN-4 2.1 Area of application................................EN-4...
English LA 1422C CAUTION! Safety notes Before opening the unit, ensure that all electric circuits are disconnected from the power supply. 1.1 Symbols and markings CAUTION! Particularly important information in these instructions is Failure to observe the safety rules could result in electric marked with CAUTION! or NOTE.
LA 1422C English 1.3 Intended use 1.5 Energy-efficient use of the heat pump This unit is only intended for use as specified by the manufac- turer. Any other use beyond that intended by the manufacturer With the purchase of this heat pump, you are helping to protect is prohibited.
English LA 1422C 2.2 Operating principle Intended use of the heat pump Heating Outside air is drawn in by the fan and fed via the evaporator 2.1 Area of application (heat exchanger). The evaporator cools the air, i.e. extracts heat from it.
LA 1422C English Scope of supply 3.1 Basic unit The heat pump contains the components listed below. The refrigeration circuit is "hermetically sealed" and contains the fluorinated refrigerant R410A incorporated in the Kyoto protocol. Information on the GWP value and CO equivalent of the refrigerant is available under “Device Information”.
English LA 1422C plates can then be pulled out of the skirt panel, the top facade Transport plates, which do not have to be removed for transport, can be hung out of the cover plate. Rehang the top panels by gently CAUTION! pushing them in an upwards direction.
LA 1422C English CAUTION! Installation In cases of installation close to walls, there may be more sediment in the intake and air outlet area due to the air flow. 5.1 General The colder outside air outlet should discharge in such a way as to not increase the heat losses in heated neighbouring rooms.
English LA 1422C 6.3 Water quality in heating Assembly systems 6.1 General 6.3.1 Scale formation The following connections need to be established on the heat pump: Scale formation in heating systems cannot be avoided, but in systems with flow temperatures below 60 °C the problem is so - Flow and return of the heating system small that it is negligible.
Page 11
LA 1422C English 6.3.2 Corrosion Filling and supplementary water as well as heating water, depending on heat output The VDI 2035 recommends the use of partially demineralised water or demineralised water in systems with larger-than-aver- Total alkaline earths in mol/m³...
Page 12
English LA 1422C Minimum heating water flow rate Saturation Index < -0.2 The minimum heating water flow rate through the heat pump -0.2 - 0.1 must be assured in all operating statuses of the heating system. 0.1 - 0.2 This can be accomplished, for example, by installing either a >...
LA 1422C English 6.4 Electrical connection A shielded communication line (not included in the scope of supply) connects the heat pump manager with the re- frigeration circuit controller installed in the heat pump. 6.4.1 General More detailed instructions can be found in the heat pump...
English LA 1422C 7.3 Procedure NOTE The primary pump (M11 – responsible for the heat source flow The heat pump is commissioned via the heat pump manager. rate) and the secondary pump (M16 – responsible for the Settings should be made in compliance with the heat pump warm/cold water flow rate) must always be clamped to the manager's instructions.
LA 1422C English NOTE needs to be performed more frequently, a 5% formic acid solu- tion should be used. Operating the heat pump at low system temperatures may cause the heat pump to break down completely. In both cases, the cleaning fluid should be at room tempera- ture.
English LA 1422C Faults/troubleshooting 10 Decommissioning/disposal This heat pump is a quality product and is designed for trouble- Before removing the heat pump, disconnect it from the power free operation. Should a fault occur, however, it will be indi- source and close all valves. The heat pump must be dismantled cated on the heat pump manager display.
LA 1422C English 11 Device Information Type and order code LA 1422C Design Heat source Seasonal coefficient of performance (COP) average climate 35 °C/55 °C 179 %/135 % Controller WPM Touch Heat generator installation location Outside Heat source installation location...
Page 18
English LA 1422C Additional model features Type of defrosting Reverse cycle Condensate tray frost protection/water in unit is protected from freezing Max. operating overpressure (heat sink) Heat output/COP Heat output/coefficient of performance (COP) EN 14511 at A-7/W35 kW / --- 7.4/3.2...
Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
LA 1422C English 14 Diagrams 14.1 Characteristic curves for heating operation Heizleistung in [kW] Wasseraustrittstemperatur in [°C] Heating capacity in [kW] Water outlet temperature in [°C] Puissance de chauffage en [kW] Température de sortie de l'eau en [°C] 2-Verdichterbetrieb 2-compressor mode Fonctionnement à...
English LA 1422C 14.2 Chartacteristic curves for cooling operation Kühlleistung in [kW] Wasseraustrittstemperatur [ Cooling capacity in [kW] Water outlet temperature in [°C] Puissance de refroidissement en [kW] Température de sortie de l'eau en [°C] Bedingungen · Conditions · Conditions: 2-Verdichterbetrieb Kühlwasserdurchsatz...
LA 1422C English 14.3 Operating limits diagram heating Wasserau (+/- 2 K) Water outlet (+/- 2 K) d'eau (+/- 2 K) *Wassereintri / *Water inlet / *Entrée d'eau Die maximalen Vorlau emperaturen werden beim geforderten Mindestheizwasserdurch uss erreicht. The maximum ow temperatures are achieved at the speci minimum he ng water ow.
English LA 1422C 14.4 Operating limits diagram cooling Wasserau (+/- 2 K) Water outlet (+/- 2 K) d'eau (+/- 2 K) Die Angaben gelten bei Einhaltung des geforderten Mindestkühlwasserdurchflusses. The values are valid for the specified minimum cooling water flow.
LA 1422C English 15 Integration diagram 15.1 Hydraulic integration diagrams NOTE The hydraulic integration diagram is an example and intended only as an aid. The system requires professional and safetyapproved layout by a specialist planner. All information in the section on installation and the corresponding safety notes must be observed at all times.
Page 26
English LA 1422C 15.2 Hydraulic integration diagrams NOTE The hydraulic integration diagram is an example and intended only as an aid. The system requires professional and safetyapproved layout by a specialist planner. All information in the section on installation and the corresponding safety notes must be observed at all times.
English LA 1422C 16 Declaration of Conformity You can find and download the current CE conformity declaration at: https://dimplex.de/la1422c EN-26 452170.66.02-EN · FD 0305 www.dimplex.de...
Page 29
LA 1422C English www.dimplex.de 452170.66.02-EN · FD 0305 EN-27...
Page 30
English LA 1422C EN-28 452170.66.02-EN · FD 0305 www.dimplex.de...
Page 31
LA 1422C English www.dimplex.de 452170.66.02-EN · FD 0305 EN-29...
Page 32
Glen Dimplex Deutschland On site service Head office After-sales service, technical support and Glen Dimplex Deutschland GmbH spare partsl. Assistance before and Am Goldenen Feld 18 after installation of your equipment D-95326 Kulmbach T +49 9221 709-545 T +49 9221 709-101...