Attaching a Power Adapter Using the Mounting Bracket AIR-ACCPMK3700-2=
Step 1
Ensure you have the mounting bracket set up as described in Step 1 through Step 13 of
AIR-ACCPMK3700-2=, on page
as No. 6 in the following figure.
Step 2
Attach the power supply using 4x 6-32 screws and torque the screws to 8.3-11 in-lbs, as shown in the following figure.
Figure 27: Power Adapter Installed Using Mounting Bracket AIR-ACCPMK3700-2=
1
Power Adapter
2
Tie Wraps
3
DC Output Cable
Step 3
Ensure that the excess cable is bundled and tie wrapped to the mounting bracket. Route the cable as shown in the figure
in Step 2.
Step 4
Ensure that there is 10 inches minimum length from the bottom edge of the power supply to the end of the connector as
shown in the figure in Step 2.
Step 5
Attach the access point to the mounting plate as described in step 14 and step 15 of
AIR-ACCPMK3700-2=, on page
Cisco Catalyst IW9167I Heavy Duty Access Point Hardware Installation Guide
32
25. But for step 11, the 2 lower bolts need to be repositioned to the locations indicated
4
5
6
25.
Using the Mounting Bracket
10 inches Minimum Length
4x 6-32 Screws
Reposition the bolts
Using the Mounting Bracket