DeWalt DXGNi35E Owner's Manual page 20

Table of Contents

Advertisement

KNOW YOUR GENERATOR
3. Control Function
3.1 Engine Smart Control (ECO)
"ON"
When the ECO switch is turned to "ON", the throttle controls the engine speed
according to the connected load. The results are better fuel consumption and
less noise.
"OFF"
When the ECO switch is turned to"OFF", the engine runs at the rated(3600r/min)
regard-less of whether is a load connected or not.
NOTICE:
The ECO must be turned to"OFF"when using electric devices that require
a large starting electric current.
3.2 Output Indicator(Green)
The output indicator comes on when the engine starts and produces power.
3.3 Overload Alarm(Red)
The overload alarm comes on when a connected device requires more power
than the generator is able to produce. THe output indicator(Green) will go off
and the overload alarm(Red) will stay on, but the engine will continue to run.
CAUTION: Do not overload the generator
3.4 Low Oil Alarm(Red)
When the oil level falls below the requires level the low oil alarm will come
on and the engine stops automatically. The engine will not resstart until oil
is added to the unit to bring it up to the appropriate level.
3.5 Multi-Switch
The multi-switch control fuel valve, choke and engine switch. When
starting the generator, rotate the multi-switch clockwise from OFF to
CHOKE position,the pull recoil cord quickly to start. After started, rotate
the switch to ON position.
NOTICE:
The choke"
" is not required to start a warm engine.
3.6 Ground Terminal
Properly ground generator to prevent electrical shock. Connect the
ground terminal of generator to ground electrode buried in the ground.
13