ELECTRICAL WIRING

230V
N
1
2
Valve
D5228
NOTES:
– Wires of min. 1 mm
(Unless requested otherwise by local standards
and legislation).
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
– To remove the control-box from the burner,
loosen screw (A) (see figure) and pull
towards the arrow.
– The flame sensor is fitted directly into the con-
trol-box (underneath the ignition-transformer)
on a plug-in support.
TESTING
Check the shut-down of the burner by opening
the thermostats.
2664
~
50Hz
L
Main switch
T6A
N
L
3
4
5
6
Black
Capacitor
2
section.
WARNING
Do not exchange the neutral with the phase.
Remote lock-out signal
(230V - 0.5A max.)
Terminal block of
7
8
9
control-box 530SE
M
~
Motor
A
RUN OF THE ELECTRICAL CABLE
1 - Cable grommet
2 - Cable-clamp
3 - Terminal block
5
GB
T
Limit thermostat
T
Safety thermostat
*
3
2
N - Neutral
L - Phase
- Burner-earth
S7026
1