Outrigger Calibration - Gs-3232 - Terex Genie GS-1932m Lite Service And Repair Manual

Hide thumbs Also See for Genie GS-1932m Lite:
Table of Contents

Advertisement

Service and Repair Manual
Ground Controls
2-8

Outrigger Calibration - GS-3232

The Electronic Control Module (ECM) is
programmed to deactivate the drive and steer
functions while the outriggers are deployed and
activate an alarm when a signal is received from
the outrigger level sensor, indicating the outriggers
are not deployed or the machine is out of level.
The ECM is also used to calibrate the outrigger
level sensor to achieve a levelness of 0° +/- 0.5°
front to back and side to side, while the outriggers
are deployed.
For further information or assistance, contact
Genie Product Support.
How to Calibrate the Outrigger
System
1
Move the machine to an area that has a firm,
level surface and is free of obstructions.
2
Turn the key switch to ground controls.
3
At the ground controls, press and hold the
Menu Up and Menu Down buttons.
4
While pressing both buttons down, pull out the
red Emergency Stop Button.
5
Release the Menu Up and Menu Down
buttons after the ground controller powers up.
6
Use the Menu Up or Menu Down buttons to
scroll to Machine Options.
7
Press the Enter button to select Machine
Options.
42
8
9
10 Use the Menu Up or Menu Down buttons to
11 Press the Enter button to select Calibrate
12 Press and hold the Enter button while the
13 Continue holding the Enter button after the
14 Continue holding the Enter button after the
15 Continue holding the Enter button after the
Note: After installing a new outrigger level sensor,
the new outrigger level sensor must be calibrated
following this procedure.
GS
-30m • 32m • 30 • 32 • 46 • 55
Use the Menu Up or Menu Down buttons to
scroll to Outriggers.
Press the Enter button to select Outriggers.
scroll to Calibrate Outriggers.
Outriggers.
system gathers data to calibrate the outrigger
level sensor.
Crushing hazard. Keep body
parts away from outriggers
during outrigger movement.
outrigger level sensor is calibrated. The
outriggers will retract while the outrigger
system gathers and saves data.
outriggers retract. The outriggers will now
extend and the system will gather and save
data to calibrate the outriggers.
outriggers extend. The outriggers will now
retract while the outrigger system gathers and
saves data.
Result: The alarms at the ground and platform
controls should sound for 1 second. The
outrigger system is calibrated.
August 2021
Part No. 1309020GT