Limit Operating Conditions:
200 A permanently to 1 kHz
Derating above 3 kHz: 200 A x (1/0.333 F), F
in kHz
Crest Factor:
3 @ 150 A peak max with an error
(due to CF) of 3 %
Overload:
240 A for 10 min ON, 30 min OFF
Working Voltage:
600 Vrms
Common Mode Voltage:
600 Vrms
Influence of Adjacent Conductor:
< 15 mA/A at 50 Hz
Influence of DC on AC signal:
DC Current < 10 A, < 10 %
Influence of Conductor Position in Jaw:
0.5 % of mV output @ 50/60 Hz
Influence of Frequency:
40 Hz to 1 kHz: 5 % of mV output
1 kHz to 10 kHz:15 % of mV output
Influence of Load:
< 3 % of mA output from 40 Hz to 1 kHz
< 12 % of mA output from 1 kHz to 10 kHz
Influence of Temperature:
≤ 200 ppm/°K, or 0.2 % of mV output per 10 °K
Influence of Humidity (10 - 90% RH):
≤ 0.2 % of mV output per 10 °K @ (18 to 28)°C
MECHANICAL SPECIFICATIONS
Operating Temperature:
(-10 to 55) °C
Storage Temperature:
(-40 to 70) °C
Operating Relative Humidity:
(10 to 35) °C 85 % RH
(without roll-off above 35 °C)
Maximum Cable Diameter:
One Ø 0.78 in (20 mm), bus bar (20 x 5) mm
Cabl Protection:
IP 40 (IEC 529)
Drop Test:
Test per IEC 68-2-32:
1.0 m drop on 38 mm of Oak on concrete.
Mechanical Shock:
Test per IEC 68-2-27
Vibration:
Test per IEC 68-2-6
Dimensions:
(5.47 x 2.00 x 1.18) in (139 x 51 x 30) mm
Weight:
180 g (6.5) oz
Polycarbonate Material:
Jaws: Polycarbonate with 10 % fiberglass charge,
Red UL 94 V)
Case: Polycarbonate 920 A Gray
Opening Operations - Life:
> 50,000
Output:
MN352: Two standard safety banana jacks (4 mm)
MN353: Double/reinforced insulated 5 ft (1.5 m)
lead with safety 4 mm banana plug
SAFETY SPECIFICATIONS
Electrical:
Double insulation or reinforced insulation between
the primary or secondary and the outer case of the
handle conforms to IEC 1010-2-32.
Common Mode Voltage:
600 V Category III
Pollution Degree 2
Dielectric Strength:
5550 V, 50/60 Hz between primary, secondary
and the outer case of the handle
Electromagnetic Compatibility:
EN 50081-1 Class B
EN 50082-2 Electrostatic discharge
IEC 1000-4-2
Radiated field IEC 1000-4-3
Fast transients IEC 1000-4-4
Magnetic field at 50/60 Hz IEC 1000-4-8
ORDERING INFORMATION
AC Current Probe MN352 ................. Cat #2116.26
AC Current Probe MN353 ................. Cat #2116.27
Accessories:
Leads, set of 2, 5 ft safety
(1000 V) for Model MN352 ................ Cat #2111.29
Banana plug adapter
(to nonrecessed plug) ........................Cat #1017.45

Advertisement

loading

This manual is also suitable for:

Mn353