Download Print this page

AEMC MN352 User Manual page 2

Ac current probe

Advertisement

ELECCTRICAL SPECIFICATIONS
Nominal Range: 150 A
Measurement Range: 0.1 to 200 A
Transformation Ratio: Voltage output
Output Signal: 10 mV/A
Accuracy and Phase Shift*:
Accuracy:
0.1 to 1 A:
≤ 3 % Reading ± 200 μV
1 to 20 A:
≤ 2 % Reading ± 200 μV
20 to 80 A:
≤ 1 % Reading
80 to 150 A:
≤ 3 % Reading
150 to 200 A: ≤ 7 % Reading
Phase Shift::
0.1 to 1 A:
Not Specified
1 to 20 A:
≤ 3 °
20 to 80 A:
≤ 2 °
80 to 150 A:
≤ 3 °
150 to 200 A: ≤ 4 °
(*Reference conditions: (18 to 28) °C,
(20 to 75) % RH, external magnetic field
< 40 A/m, (48 to 65) Hz sine wave, distortion
factor less than 1 %, no DC component, no
external current carrying conductor, test sample
centered.)
Load impedance > 1 MΩ.
Frequency Range:
(40 to 10) kHz

Advertisement

loading

This manual is also suitable for:

Mn353