Equipment Parameter Configuration Interface; Screen Sleep - Ebyte ME31-XXAX0060 User Manual

Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
6. Local port;
7. Local IP address;
8. Network mode;
9. Gateway;
10. Subnet mask;
11. DNS;
12. MAC address;
13. DHCP;
14. Target IP;
15. Destination port;
16. Modbus TCP/RTU protocol conversion;
17. Active upload;
18. Modbus address filtering;;

4.5.3. Equipment Parameter Configuration Interface

Press and hold the confirmation button to enter the password input interface, complete the correct password
input, and enter the configuration interface (password interface: default password: 0000; short press the middle to
verify the password, the left and right buttons switch the password bit, and the up and down buttons switch the
value of the current bit , the password has a total of 4 digits, and each input range is a number from 0-9).
Select the setting item, enter the parameter configuration page and short press the up and down keys to switch
the setting item;
Select the setting item, short press to confirm or right click, the setting item gets the cursor to represent the
selection and enter the setting item;
Adjust the parameter value: After selecting the setting item, the up and down keys can change the value or
optional value; the left and right keys move the cursor in the parameter item;
Confirm the parameter value: After adjusting the parameter value, press the enter key to exit the current
setting item.
Save parameter settings and restart: After setting the parameters, move the cursor to save and restart, then
short press the confirmation key to enter the confirmation save and restart state. Short press the confirmation key
(press other keys to exit the confirmation state) to save the parameters and restart the device.
Exit without saving parameters: move the cursor to exit, then short press the confirmation key to enter the
confirmation exit state, short press the confirmation key (press other keys to exit the confirmation state), and then
exit the parameter configuration interface without saving the parameters .
Among them, the data bit and stop bit cannot be set. After the DHCP mode is turned on, the local IP address,
gateway, and subnet mask cannot be configured and are only assigned by the router;

4.5.4. Screen Sleep

The device screen has a sleep function, which is off by default and can be set to on in the configuration
interface.
In any interface, when there is no button operation for 180 seconds, the screen will enter the sleep mode. At
this time, the interface displays Ebyte robot. Press any button can exit the sleep mode.
When the screen is in sleep mode, the running efficiency of device programs will be improved.