4.4.1. Information Display Interface

Including the AO input value display page, short press the up and down buttons to switch the interface.

4.4.2. Equipment parameter display interface

Press the left button or right button to enter the password input interface, complete the correct password input,
and the device parameter information interface will be displayed (password interface: default password: 0000; short
press the middle to verify the password, the left and right buttons switch the password bit, and the up and down
buttons switch the current bit value, the password has a total of 4 digits, and each input is a number ranging from
0-9):
The parameter setting interface from top to bottom is:
1. Modbus address;
2. Baud rate;
3. Data bits;
4. Check Digit;
5. Stop bit;
6. Local port;
7. Local IP address;
8. Gateway;
9. Subnet mask;
10. DNS;
11. MAC address;
12. DHCP;
13. Target IP;
14. Destination port;
15. Modbus TCP/RTU protocol conversion;
16. Active upload;
17. Modbus address filtering;

4.4.3. Equipment Parameter Configuration Interface

Press and hold the confirmation button to enter the password input interface, complete the correct password
input, and enter the configuration interface (password interface: default password: 0000; short press the middle to
verify the password, the left and right buttons switch the password bit, and the up and down buttons switch the
value of the current bit , the password has a total of 4 digits, and each input range is a number from 0-9).
Select the setting item, enter the parameter configuration page and short press the up and down keys to switch
the setting item;
Select the setting item, short press to confirm or right click, the setting item gets the cursor to represent the
selection and enter the setting item;
Adjust the parameter value: After selecting the setting item, the up and down keys can change the value or
optional value; the left and right keys move the cursor in the parameter item;
Confirm the parameter value: After adjusting the parameter value, press the enter key to exit the current