Pressure Applications; Pressure Equipment Directive, Ped, 2014/68/Eu - Siemens SITRANS LR250 Compact Operating Instructions

Radar level transmitters
Hide thumbs Also See for SITRANS LR250:
Table of Contents

Advertisement

Installing/mounting
4.1 Basic safety information
4.1.2

Pressure applications

Pressure applications
Danger to personnel, system and environment will result from improper disassembly.
• Never attempt to loosen, remove, or disassemble process connection while vessel
Pressure applications
Danger to personnel, system and environment can result from improper installation.
• Improper installation may result in loss of process pressure.
Exceeded maximum permissible operating pressure
Danger of injury or poisoning.
The maximum permissible operating pressure depends on the device version. The device
can be damaged if the operating pressure is exceeded. Hot, toxic and corrosive process
media could be released.
• Make sure that the device is suitable for the maximum permissible operating pressure of
Note
• The process connection tag shall remain with the process pressure boundary assembly.
(The process pressure boundary assembly comprises the components that act as a barrier
against pressure loss from the process vessel: that is, the combination of process
connection body and emitter, but normally excluding the electrical enclosure). In the
event the device package is replaced, the process connection tag shall be transferred to
the replacement unit.
• Representative samples of this device have been hydrostatically tested, meeting or
exceeding the requirement of the ASME Boiler and Pressure Vessel Code and the European
Pressure Equipment Directive.
4.1.2.1

Pressure Equipment Directive, PED, 2014/68/EU

Siemens Level Transmitters with flanged, threaded, or sanitary clamp type process mounts
have no pressure-bearing housing of their own and, therefore, do not come under the
Pressure Equipment Directive as pressure or safety accessories (see EU Commission Guideline
A-08 and A-20).
18
DANGER
contents are under pressure.
WARNING
WARNING
your system.
SITRANS LR250 with FOUNDATION FIELDBUS
Compact Operating Instructions, 09/2021, A5E48453221-AB

Advertisement

Table of Contents
loading

This manual is also suitable for:

7ml54317ml54327ml5433

Table of Contents