4.2 Physical Mounting

To mount MASTER or SLAVE, select a location and provide a bored hole with screw
in the middle of the wall for each device. Now hang the devices on the tabs there.
The holes to the left and right in the terminal area can be used as a drilling jig for the
two other screw attachments.
Any SLAVES can be installed directly next to the MASTER.
Ensure that the max. distance between MASTER and SLAVE is not longer than the
length of the data cable in the SLAVE.
Be sure to consider the following points when selecting the installation location.
• Do not install in rooms where extremely high temperatures occur and care for
enough ventilation because of the waste heat. High ambient temperatures reduce
the power output. (see chapter 5.4)
• This would probably shorten the life expectancy of the device. See technical data.
• Do not install in areas where condensation can occur.
• Do not mount on flammable bases (e.g., wood or fiberboard).
• Objects which may catch fire do not belong in the vicinity of the device. Allow at
least 1 m distance.
• Leave approx. 50 cm of free space above and below the devices so that air can
circulate freely.
Dimensions in mm
Siemens AG
C98130-A7580-A1-1-7619
SITOP solar
08/2006
6
17
Figure 3: Mounting drawing
*
holes for attachment screws
*
139
tab for attachment