Activation And Deactivation Of The Running Light - Siemens SITOP solar User Manual

Solar inverter
Table of Contents

Advertisement

Battery empty ...
The battery is used to maintain the stored data in the data logger and about the total
yield and hours of operation. By empty battery, these data get lost.
Possible cause:
Battery voltage is less than 2.7 V.
Further actions:
Replace the battery as described in chapter 4.5.1.
Always also document all switchoff events on the internal data logger where they can
be read when necessary with SITOP solar log.

6.3 Activation and Deactivation of the Running Light

When your inverter is delivered, the running light below the display has already been
activated at the plant. If you want to deactivate it, keep the push button to the right of
the display pressed for 5 seconds.
If you want to activate the running light again, hold the button down again for 5
seconds.
Siemens AG
C98130-A7580-A1-1-7619
Page 26 of 34
SITOP solar
08/2006

Advertisement

Table of Contents
loading

Table of Contents