Seasonal Auto Temp - LG THERMA V HM093MR Installation Manual

Air-to-water heat pump
Table of Contents

Advertisement

Seasonal auto temp

It is the function to set the operation reference value in Seasonal Auto mode.
• In the installer setting list, select Seasonal auto temp category, and press [OK] button to move
to the detail screen.
Function
Outdoor1,Heat (Out1) Heating lower ambient temp
Outdoor2,Heat (Out2) Heating higher ambient temp
Outdoor3,Cool (Out3) Cooling lower ambient temp
Outdoor4,Cool (Out4) Cooling higher ambient temp
Water1,Heat (LW1)
Heating higher water temp
Water 2,Heat (LW2)
Heating lower water temp
Water3,Cool (LW3)
Cooling higher water temp
Water4,Cool
Cooling lower water temp
(LW4)
Air 1, Heat (RA1)
Heating higher air temp
Air 2, Heat (RA2)
Heating lower air temp
Air 3, Cool (RA3)
Cooling higher air temp
Air 4, Cool (RA4)
Cooling lower air temp
- Setting range: Celsius
- Seasonal Auto Driving mode: Heating, Heating & Cooling, Air-conditioning
* If heating mode is selected, heating & cooling or cooling can not be selected.
- Depending on the air / outflow control selection value, the water / air related setting value is
displayed on the screen.
OK
Description
Use heater :
LW STD : 15~65 °C
EW STD : 15~55 °C
Not use heater :
LW STD : 20~65 °C
EW STD : 20~55 °C
Use FCU & 5 °C
IDU :
LW STD : 5~27 °C
EW STD : 10~27 °C
Use FCU & 6 °C
IDU :
LW STD : 6~27 °C
EW STD : 11~27 °C
Not use FCU :
LW STD : 16~27 °C
EW STD : 20~27 °C
INSTALLER SETTING
Range
Default
-10 °C
-25 ~ 35 °C
16 °C
30 °C
10 ~ 46 °C
40 °C
35 °C
28 °C
20 °C
16 °C
30 °C
16 ~ 30 °C
26 °C
22 °C
18 ~ 30 °C
18 °C
179
Boundary
Out1 ≤ Out2-1
Out2 ≥ Out1 +1
Out2 ≤ Out3 -5
Out3 ≥ Out2 +5
Out3 ≤ Out4 -1
Out4 ≥ Out3 +1
LW1 ≤ LW2
LW2 ≤ LW1
LW3 ≤ LW4
LW4 ≤ LW3
RA1 ≤ RA2
RA2 ≤ RA1
RA3 ≤ RA4
RA4 ≤ RA3