Seasonal Auto Temp - LG Therma V AHUW096A3 Installation Manual

Air-to-water heat pump
Hide thumbs Also See for Therma V AHUW096A3:
Table of Contents

Advertisement

Seasonal auto temp

It is the function to set the operation reference value in Seasonal Auto mode.
• In the installer setting list, select Seasonal auto temp category, and press [OK] button to move
to the detail screen.
Function
Outdoor1,Heat
Heating lower ambient temp
(Out1)
Outdoor2,Heat
Heating higher ambient temp
(Out2)
Outdoor3,Cool
Cooling lower ambient temp
(Out3)
Setting maintain temperature
Tank setting 2
for operation
Water1,Heat
Heating higher water temp
(LW1)
Determine follow time
duration : operation time of
domestic hot water tank
DHW time
heating, stop time of domestic
setting
hot water tank heating, and
delay time of DHW tank heater
operating
Water3,Cool
Cooling higher water temp
(LW3)
Water4,Cool
Cooling lower water temp
(LW4)
- Setting range: Celsius
- Seasonal Auto Driving mode: Heating, Heating & Cooling, Air-conditioning
* If heating mode is selected, heating & cooling or cooling can not be selected.
- Depending on the air / outflow control selection value, the water / air related setting value is
displayed on the screen.
OK
Description
INSTALLER SETTING
Range
Default
-25~35 °C
10~46°C
Use heater :
LW STD : 15~65°C
EW STD : 15~55°C
Not use heater :
LW STD : 20~65°C
EW STD : 20~55°C
Use FCU & 5°C IDU :
LW STD : 5~27°C
EW STD : 10~27°C
Use FCU & 6°C IDU :
LW STD : 6~27°C
EW STD : 11~27°C
Not use FCU :
LW STD : 16~27°C
EW STD : 20~27°C
123
Boundary
Out1 ← Out2-1
-10°C
Out2 → Out1 +1
16°C
Out2 ← Out3 -5
Out3 → Out2 +5
30°C
Out3 ← Out4 -1
Out4 → Out3 +1
40°C
LW1 ← LW2
35°C
LW1 ← LW2
28°C
LW3 ← LW4
20°C
LW3 ← LW4
16°C