Download Print this page

NEC Express5800/R120h-1E Manual page 38

Hide thumbs Also See for Express5800/R120h-1E:

Advertisement

● Note on using NEC ESMPRO Manager (Windows) and Express Report Service (MG)
Depending on the combination of iLO firmware version of this product with NEC ESMPRO Manager (Windows) and
Express Report Service (MG) (Windows), it may be necessary to update NEC ESMPRO Manager (Windows) and iLO
Receiving Information (ilo en.mtb). Please refer to the end of this chapter to confirm/update to the latest version, if needed.
◆Phenomena regarding NEC ESMPRO Manager (Windows)
iLO firmware
NEC ESMPRO
version
Manager
(Windows) Version
2.10 or higher
Lower than 6.25
Lower than 6.47
◆Updating NEC ESMPRO Manager Ver 6 (Windows)
(1) Download the latest version of NEC ESMPRO Manager from the following website.
https://www.58support.nec.co.jp/global/download/index.html
- ESMPRO tab
- NEC ESMPRO Manager
(2) Update NEC ESMPRO Manager. For details, refer to Chapter 2 Installation in "NEC ESMPRO Manager Ver. 6
Installation Guide (Windows) [PDF]".
◆Updating NEC ESMPRO Manager Ver 7 (Windows)
(1) Download the latest version of NEC ESMPRO Manager from the following website.
https://www.58support.nec.co.jp/global/download/index.html
- ESMPRO tab
- NEC ESMPRO Manager
(2) Launch the ESMPRO installation tool included in the ESMPRO Platform Management Kit.
(3) On the "Installation Tools screen" click on "Instructions", then from Software Manuals click on
"ESMPRO/ServerManager.
(4) Click on "ESMPRO/ServerManager Ver.7.00 Installation Guide (Windows)".
(5) For more details on "Update NEC ESMPRO Manager from Ver 6 to Ver 7", refer to Chapter 2 Installation in "NEC
ESMPRO Manager Ver. 7 Installation Guide (Windows) [PDF]".
◆Phenomena regarding iLO Receiving Information (ilo_en.mtb)
* Intend for users of NEC Express Report Service (MG)
iLO firmware
iLO Receiving Information
version
Version
2.10 or higher
ilo_en.mtb
Lower than 1.4.0
iml_en.mtb
Lower than 1.5.0
* There are 2 kinds of iLO
Receiving Information.
Phenomena
・ Configuration Tab - Server Status screen
"SNMP Alert setting" will show error message "Failed to get SNMP Alert
setting".
・ Remote Control Tab - iLO Information - Show IML or Save IML
NEC ESMPRO Manager will fail to get IML information and Show IML or
Save IML feature will not work.
・ AlertViewer
New Alerts of hardware failure added with firmware update will be
displayed as "Unknown" alert on AlertViewer.
・ AlertViewer
New Alerts of hardware failure added with firmware update will be
displayed as "Unknown" alert on AlertViewer, or they will not be displayed
on AlertViewer.
Phenomena
It is impossible to detect a failure of the hardware added along
with the update of hardware and to issue an alert of this failure.
* If iLO Receiving Information has been updated and NEC
ESMPRO Manager has not been updated, it is impossible to
detect the failure of the added hardware and issue the alert of the
failure, as with the above.
38

Advertisement

loading

This manual is also suitable for:

Express5800/r120h-2e