Panasonic KX-TCD735AXM Service Manual page 72

Digital cordless answering system
Table of Contents

Advertisement

Address
Default
0F06
28
0F07
3C
0F08
64
0F09
0A
0F0A
4A
0F0B
08
0F0C
14
0F0D
46
0F0E
28
0F0F
82
0F10
82
0F11
FF
0F12
64
0F13
08
Name
MakeTime
BreakTime
DtmfTime
InterDigitDtmfTime
InterDigitPulseTime
CalibBreakTime[0]
CalibBreakTime[1]
CalibBreakTime[2]
CalibBreakTime[3]
CalibBreakTime[4]
CalibBreakTime[5]
LineSeizureEndTime
RingTermToU100
RingPatternToU100
Type
D
Pulse make time.
Unit : 1 ms. defaults to 40 ms.
D
Pulse break time
Unit : 1 ms, defaults to 60 ms.
D
DTMF tone pulse time.
Unit : 1 ms, defaults to 100 ms.
D
Inter-digit time in DTMF mode.
Unit : 10 ms , defaults to 100ms.
D
Inter-digit time in Pulse mode.
Unit : 10 ms, defaults to 740 ms.
D
Calibrated loop-break time for short
Unit : 10 ms, defaults to 80 ms.
D
Calibrated loop-break time for long
Unit : 10 ms, defaults to 200 ms.
D
Calibrated loop-break time for extra
break
Unit : 10 ms, defaults to 700 ms.
D
Calibrated earth-break time for short
Unit : 10 ms, defaults to 400 ms.
D
Calibrated earth-break time for long
Unit : 10 ms, defaults to 1300 ms.
D
Calibrated earth-break time for extra
break
Unit : 10 ms, defaults to 1300 ms.
D
Line seizure end-time - time after hook
Meter-pulse detection continues during
period of time.
00h or FFh means 10 ms.
Unit : 10 ms, defaults to 10 ms.
D
Ring terminate time-out period. This
max time that
must elapse between two ring-voltage
bursts before the
new ring-voltage is registered as a
incoming call.
Unit: 100 ms. defaults to approx 10
D
Ring pattern timeout. Max. silence
during distinctive
ringing. As long as the silence period
not exceed this
period of time the ring is still considered
and counted as
one single ring.
Unit : 100 ms. Defaults to 800 ms
72