Ve: Display Of Version; Monitor Menu; Vf: Flow Display; Te: Display Of Final Power Stage Temperature - DAB PUMPS MCE-22/P Instruction For Installation And Maintenance

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 65
To reserve more space for the system display, the name of the parameter SM is not shown, but simply the text "system"
below the menu name
6.1.6

VE: Display of version

Hardware and software version of the equipment.
For firmware versions 26.1.0 and later, the following also applies:
On this page after the prefix S: the last 5 figures of the single serial number attributed for connectivity are showed. The whole serial
number can be viewed by pressing the "+" key
6.2

Monitor menu

The MONITOR MENU is accessed from the main menu by pressing and holding the buttons "SET" and "-" (minus) simultaneously for
2 seconds, or via the selection menu using buttons + or -.
Within this menu, by pressing MODE, the following values are displayed consecutively.
6.2.1

VF: Flow display

This displays the instant flow in [litres/min] or [gal/min] depending on the set unit of measurement. If the mode without flow sensor is
selected, an adimensional flow is displayed.
6.2.2

TE: Display of final power stage temperature

6.2.3

BT: Display of electronic board temperature

6.2.4

FF: Display of fault log

Chronological display of faults occurring during system operation.
Tow numbers x/y are displayed below the symbol FF, which indicate respectively "x" for the fault displayed and "y" for the total number
of faults present; an indication of the type of fault is displayed to the right.
Buttons + and – can be used to scroll through the list of faults: press – to move back through the log through to the oldest fault present,
or + to scroll forward to the most recent.
The faults are shown in chronological order, starting from the oldest x=1 to the most recent x=y. The maximum number of faults
displayable is 64; after which the system overwrites the oldest versions in order.
This menu item displays the fault list but does not enable reset. The list can only be cleared by means of the specific command in the
item RF of the TECHNICAL ASSISTANCE MENU.
Neither a manual reset or shutdown of the unit, or restored default settings will clear the fault log; only the above procedure will enable
this.
6.2.5

CT: Display contrast

This adjusts the display contrast.
6.2.6

LA: Language

Display in one of the following languages:
Italian
English
French
German
ENGLISH
.
.
100

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mce-15/pMce-11/pMce-55/pMce-30/pMce-150/pMce-110/p

Table of Contents