Connect the Grounding Cable

We recommend that you ground the AP before mounting it on a wall or pole. The AP61 has a single-
hole protective grounding terminal on the rear. Use this grounding terminal to ground the AP.
To ground the AP61:
1. Remove the screw from the grounding terminal.
2. Place the grounding lug attached to the grounding cable over the grounding terminal. We
recommend a minimum of 18-AWG wire for the AP.
3. Secure the grounding cable lug to the grounding terminal with the screw.

Mount the AP61 on a Wall (Flush Mount)

To flush mount the AP61 on a wall:
1. Drill four holes on the wall in such a way that they align with the location of holes marked with
callout #1 in
Figure 5 on page
2. Insert screws in the two upper holes. Do not tighten the screws fully.
3. Attach the APOUTBR-FM flush mount bracket to the AP by using the four screws, washers, and
spring washers provided along with the AP.
Use the bracket screw holes marked with callout #3 in
13. Insert anchors in all the four holes.
Figure 5 on page
13.