Personal Protective Equipment; Rules Of Electrical Safety; Warranty; Delivery, Transport, Storage - SystemAir KBR 355EC-K Installation And Operating Instructions Manual

Thermo box
Table of Contents

Advertisement

2

| Warranty

Table 1 Qualifications
Activities
Storage, operation, transport, cleaning, disposal
Electrical connection, commissioning, electrical
disconnection
Installation, disassembly
Maintenance
Repair
Note:
The operator is responsible for ensuring that personnel are instructed and have understood the contents of
the operating instructions. If something is unclear, please contact Systemair or its representative.
2.2

Personal protective equipment

♦ Wear protective equipment during all work in the vicinity of the fan.
• protective working clothes
• protective working shoes
2.3

5 rules of electrical safety

1. Disconnect (disconnection of
the electrical system from
live components at all
terminals)
3
Warranty
For the assertion of warranty claims, the products must be correctly connected and operated, and used in accordance
with the data sheets. Further prerequisites are a completed maintenance plan with no gaps and a commissioning re-
port. Systemair will require these in the case of a warranty claim. The commissioning report is a component of this
document. The maintenance plan must be created by the operator, see section 12.2 Maintenance, page 13.
4

Delivery, transport, storage

Safety information
Warning: Risk from rotating fan blades
♦ Prevent access by unauthorised persons by safety personnel or access protection.
Warning: Suspended loads
♦ Do not walk under suspended loads.
♦ Make sure that there is nobody under a suspended load.
Delivery
Each fan leaves our plant in an electrically and mechanically proper condition. We recommend transporting the fan to
the installation site in the original packaging.
Checking delivery
♦ Check the packaging and the fan for transport damage. Any findings should be noted on the cargo manifest.
♦ Check completeness of the delivery.
Qualifications
Trained personnel (see following note)
Electrical expert or matching qualification
Fitter or matching qualification
Electrical expert or matching
qualification
Electrical expert or matching
qualification
Smoke extraction fans and EX fans only by agreement with
Systemair.
• protective working gloves
• helmet
2. Prevent reactivation
3. Test absence of voltage
Fitter or matching
qualification
Fitter or matching
qualification
• goggles
• hearing protection
4. Ground and short-circuit
5. Cover or restrict adjacent live parts
| 004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kbr/f seriesKbr seriesKbr 355ec-l

Table of Contents