Rodix FEEDER CUBE FC-92 Plus Manual

Rodix FEEDER CUBE FC-92 Plus Manual

Advertisement

FEEDER CUBE ®
Plus
FC-92
GENERAL PURPOSE MODEL
IMPORTANT: APPLICATION NOTE
Input: 120 VAC, 50/60 HZ.
(Operating range 90-130 VAC)
Double Unit Fuse Sizes:
Unit A 10A, Unit B 5A
Output: 0-120 VAC
Unit A: 100% Duty Cycle 0.6-8A, 80% for 9-10A
Unit B: 100% Duty Cycle 0.6-4A, 80% for 5A
Circuit Boards P/N 24-490 & 24-210
Unit A Information: This unit is based on the FC-90
output can be controlled with an optional part sensor. For more information on this unit, refer to the enclosed Adjustments
and Set Up pages.
Unit B Information: This unit is based on the FC-40
to the enclosed Adjustments and Set Up pages. The Unit B operation is independent of the other unit.
© 2000, 2018 RODIX
RODIX INCORPORATED
TOLL FREE (800) 562-1868, FAX (815) 316-4701
E-mail custserve@rodix.com
, P/N 121-000-8450
Plus
Plus
.
INC
rodix.com
Series Part Sensing Feeder Cube®. The On/Off operation of the
Series Feeder Cube®. For more information on this unit, refer
File No. E183233
8.75
8.0
9.0
FC-92.docx 2/16/2018
4.0
4.5
2.0
4.8
4.0
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FEEDER CUBE FC-92 Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for Rodix FEEDER CUBE FC-92 Plus

  • Page 1 Unit B Information: This unit is based on the FC-40 Series Feeder Cube®. For more information on this unit, refer to the enclosed Adjustments and Set Up pages. The Unit B operation is independent of the other unit. 8.75 © 2000, 2018 RODIX FC-92.docx 2/16/2018 Page 1...
  • Page 2: Sensor Option

    RUN JUMPER INPUT FEEDER BOWL/HOPPER LOW VOLTAGE INPUT RODIX INC. INTERLOCK SWITCHING P/N 24-490/24-491  FEEDER CUBE FC-90 PLUS SERIES TB2, OUTPUT (DC Voltage from PLC) LOW CURRENT SWITCH FC-90 Plus Series 5-30 VDC INPUT VOLTAGE OFF/ON CONTROL WIRING DIAGRAM ...
  • Page 3: Adjustments & Set Up

    R3. R3 is located on the circuit maintain a constant part feed rate. linear pot taper for the Main Control Dial, see the “S1 board near TB2-8. Programming Chart.” © 2000, 2018 RODIX FC-90 Plus Set Up J.docx 2/21/2018 Page 3...
  • Page 4 B. CHOOSE A LOCATION for mounting the sensor Plus A. 4-20mA signal from a PLC can be used to remotely can be connected to a Rodix FC-40 Series on the feeder that is smooth and that will allow the Plus vary the output of the control instead of the Main (TB2-11 &...
  • Page 5: Warranty

    OUT of warranty service, please ship it prepaid to: Rodix Inc., ATTN: Repair Department packaging. Remove the liner from the adhesive Included features: Constant On, High/Low Track level If under warranty, Rodix will repair or replace your control backing. Avoid touching the tape. Align the control, 60 pulse polarity reversal, low pulse rate, at no charge;...
  • Page 6 "Parts Sensing Feeder Bowl Control" such as an available for use on applications requiring a three Plus FC-90 wire DC sensor, an interlock output, or a Constant Feed Rate (vibration feedback) sensor. FC-40 Plus Set Up.doc 2/21/2018 Page 6 © 2000, 2017 RODIX...
  • Page 7 ON and OFF. Move jumper "J1" from terminal If under warranty, Rodix will repair or replace your control pots. See the S1 Switch Programming Chart. For 7, to terminal 5, (6 remains the same). Then at no charge;...
  • Page 8: Rodix Solution

    Rodix controls have been designed with a AUX output. The shield “drain” wire high degree of immunity to electrical should be tied to the chassis in the Rodix RECTIFIER noise; however, depending on the control RELAY DIODE control. The drain wire should be kept...

This manual is also suitable for:

121-000-8450

Table of Contents