ENGLISH
Temperature correction for temperature > 110°C :
C = E
/ E
tm
20b
With E
: material modulus of elasticity at 20°C and E
20b
temperature.
Assembly on cast iron base frame :
Discharge z axis :
F
F
F
y
z
x
(N)
(N)
(N)
100
1080
1340
1200
125
1280
1580
1420
150
1620
2000
1800
200
2160
2680
2400
250
2700
3340
2980
300
3220
4000
3580
350
3760
4660
4180
Suction x axis :
F
F
F
y
z
x
(N)
(N)
(N)
125
1420
1280
1580
150
1800
1620
2000
200
2400
2160
2680
250
2980
2700
3340
300
3580
3220
4000
350
4180
3760
4660
400
4780
4300
5320
Assembly on grouted cast iron base frame :
Discharge z axis :
F
F
F
y
z
x
(N)
(N)
(N)
100
1490
1840
1650
125
1790
2210
1990
150
2300
2830
2550
200
3110
3850
3450
250
3920
4840
4320
300
4700
5830
5220
350
5510
6820
6120
Suction x axis :
F
F
F
y
z
x
(N)
(N)
(N)
125
1990
1790
2210
150
2550
2300
2830
200
3450
3110
3850
250
4320
3920
4840
300
5220
4700
5830
350
6120
5510
6820
400
7020
6320
7810
at calculation
tm
F
M
M
M
y
z
x
(N)
(N.m)
(N.m)
(N.m)
2100
500
580
700
2480
600
760
840
3140
700
820
1000
4200
920
1060
1300
5230
1260
1460
1780
6260
1720
1980
2420
7300
2200
2540
3100
F
M
M
M
y
z
x
(N.m)
(N.m)
(N.m)
(N)
2480
600
760
840
3140
700
820
1000
4200
920
1060
1300
5230
1260
1460
1780
6260
1720
1980
2420
7300
2200
2540
3100
8350
2760
3180
3880
F
M
M
M
y
z
x
(N)
(N.m)
(N.m)
(N.m)
2880
700
810
980
3470
900
1140
1260
4450
1120
1310
1600
6030
1660
1910
2340
7580
2520
2920
3560
9130
3780
4360
5320
10690
5280
6100
7440
F
M
M
M
y
z
x
(N)
(N.m)
(N.m)
(N.m)
3470
900
1140
1260
4450
1120
1310
1600
6030
1660
1910
2340
7580
2520
2920
3560
9130
3780
4360
5320
10690
5280
6100
7440
12260
7180
8270
10090
5.2.7
Pump can be delivered as a complete pump set including electrical
motor, flexible coupling, coupling guard and baseplate. It can be also
delivered without one of those parts. A CE integration certificate is then
supplied.
M
This instructions and operating manual is part of the pump supply and
(N.m)
should be delivered attached to the pump. If not, ask SALMSON
Customer department to get it.
1040
ATEX pumps may be delivered with specific instrumentation. Refer
1280
to pump technical datasheet or to acknowledgment of order to
1470
know exhaustive scope of supply.
1910
6
DESCRIPTION AND WORKING PRINCIPLE
2620
3570
6.1 PRODUCT INFORMATION
4570
NOEH pump is a single stage PN16 or PN20 volute casing pump designed
for horizontal installation. Dimensions meet ISO2858 requirements. Its
M
mechanical design is according to ISO5199.
N.m)
The back pull‐out design of the ball bearing assembly permits
dismantling of the impeller while suction and discharge lines are
1280
fastened to casing flanges.
1470
If a coupling spacer is used the motor won't have to be moved rearward
1910
during maintenance operation.
This pump is designed to handle overheated water up to 180°C thanks to
2620
a specific shaft sealing arrangement and auxiliary system.
3570
The bearing bracket is equipped with angular contact oil lubricated ball
4570
bearings on drive side to handle most demanding applications.
5730
6.2 FUNCTION
NOEH pump is a centrifugal pump with axial inlet and radial outlet.
Pump speed is 1450 RPM.
An impeller turns inside the pump casing (direction of rotation is
M
clockwise seen from drive end). The rotation movement is transmitted
(N.m)
to the fluid that is driven to the vanes and then pumped to the discharge
1450
flange where it leaves the pump. In the flow passage of the pump casing
the kinetic energy of the fluid is converted into pressure energy.
1920
NOEH pumps are not self‐priming. Suction line and pump casing should
2350
be completely filled with liquid before pump start.
3440
When necessary or when a maximum pumping efficiency is required
several possibilities are offered to adapt capacity/pressure.
5250
Modification of the system hydraulic characteristics :
7850
A regulating valve is added at the discharge side of the pump. The
hydraulic loss can be adjusted and so the pump duty point.
10970
Modification of pump characteristics :
Use of a frequency inverter gives the possibility to adjust pump speed.
The pump hydraulic curve is modified to reach required duty point but
M
impeller diameter is unchanged.
N.m)
1920
7
INSTALLATION
2350
CONNECTION
3440
7.1 LOCATION
5250
7850
regulations.
10970
14890
The choice of the pump location should permit a proper cooling of the
motor and should respect following limits :
10
SCOPE OF DELIVERY
AND
Equipments that will be used in a ATEX zone should be
certified accordingly and should fully comply with applicable
ELECTRICAL