Temperature correction for temperature > 110°C : 
C = E
 / E
 
tm
20b
With  E
 :  material  modulus  of  elasticity  at  20°C  and  E
20b
temperature. 
 
Assembly on cast iron base frame : 
Discharge z axis : 
F
 
F
 
F
 
y
z
x
(N) 
(N) 
(N) 
100 
1080 
1340 
1200 
125 
1280 
1580 
1420 
150 
1620 
2000 
1800 
200 
2160 
2680 
2400 
250 
2700 
3340 
2980 
300 
3220 
4000 
3580 
350 
3760 
4660 
4180 
Suction x axis : 
F
 
F
 
F
 
y
z
x
(N) 
(N) 
(N) 
125 
1420 
1280 
1580 
150 
1800 
1620 
2000 
200 
2400 
2160 
2680 
250 
2980 
2700 
3340 
300 
3580 
3220 
4000 
350 
4180 
3760 
4660 
400 
4780 
4300 
5320 
 
Assembly on grouted cast iron base frame : 
Discharge z axis : 
F
 
F
 
F
 
y
z
x
(N) 
(N) 
(N) 
100 
1490 
1840 
1650 
125 
1790 
2210 
1990 
150 
2300 
2830 
2550 
200 
3110 
3850 
3450 
250 
3920 
4840 
4320 
300 
4700 
5830 
5220 
350 
5510 
6820 
6120 
 
Suction x axis : 
F
 
F
 
F
 
y
z
x
(N) 
(N) 
(N) 
125 
1990 
1790 
2210 
150 
2550 
2300 
2830 
200 
3450 
3110 
3850 
250 
4320 
3920 
4840 
300 
5220 
4700 
5830 
350 
6120 
5510 
6820 
400 
7020 
6320 
7810 
 
 
  at  calculation 
tm
F 
M
 
M
 
M
 
y
z
x
(N) 
(N.m) 
(N.m) 
(N.m) 
2100 
500 
580 
700 
2480 
600 
760 
840 
3140 
700 
820 
1000 
4200 
920 
1060 
1300 
5230 
1260 
1460 
1780 
6260 
1720 
1980 
2420 
7300 
2200 
2540 
3100 
F 
M
 
M
 
M
 
y
z
x
(N.m) 
(N.m) 
(N.m) 
(N) 
2480 
600 
760 
840 
3140 
700 
820 
1000 
4200 
920 
1060 
1300 
5230 
1260 
1460 
1780 
6260 
1720 
1980 
2420 
7300 
2200 
2540 
3100 
8350 
2760 
3180 
3880 
F 
M
 
M
 
M
 
y
z
x
(N) 
(N.m) 
(N.m) 
(N.m) 
2880 
700 
810 
980 
3470 
900 
1140 
1260 
4450 
1120 
1310 
1600 
6030 
1660 
1910 
2340 
7580 
2520 
2920 
3560 
9130 
3780 
4360 
5320 
10690 
5280 
6100 
7440 
F 
M
 
M
 
M
 
y
z
x
(N) 
(N.m) 
(N.m) 
(N.m) 
3470 
900 
1140 
1260 
4450 
1120 
1310 
1600 
6030 
1660 
1910 
2340 
7580 
2520 
2920 
3560 
9130 
3780 
4360 
5320 
10690 
5280 
6100 
7440 
12260 
7180 
8270 
10090 
 
 
 
5.2.7
Pump  can  be  delivered  as  a  complete  pump  set  including  electrical 
motor,  flexible  coupling,  coupling  guard  and  baseplate.  It  can  be  also 
delivered without one of those parts. A CE integration certificate is then 
supplied. 
M 
This  instructions  and  operating  manual  is  part  of  the  pump  supply  and 
(N.m) 
should  be  delivered  attached  to  the  pump.  If  not,  ask  SALMSON 
Customer department to get it. 
1040 
ATEX pumps may be delivered with specific instrumentation. Refer 
1280 
to  pump  technical  datasheet  or  to  acknowledgment  of  order  to 
1470 
know exhaustive scope of supply. 
 
1910 
6
DESCRIPTION AND WORKING PRINCIPLE 
2620 
3570 
 
6.1 PRODUCT INFORMATION 
4570 
NOEH pump is a single stage PN16 or PN20 volute casing pump designed 
for  horizontal  installation.  Dimensions  meet  ISO2858  requirements.  Its 
M 
mechanical design is according to ISO5199. 
N.m) 
The  back  pull‐out  design  of  the  ball  bearing  assembly  permits 
dismantling  of  the  impeller  while  suction  and  discharge  lines  are 
1280 
fastened to casing flanges. 
1470 
If a coupling spacer is used the motor won't have to be moved rearward 
1910 
during maintenance operation. 
This pump is designed to handle overheated water up to 180°C thanks to 
2620 
a specific shaft sealing arrangement and auxiliary system. 
3570 
The bearing bracket is equipped with angular contact oil lubricated ball 
4570 
bearings on drive side to handle most demanding applications. 
 
5730 
6.2 FUNCTION 
NOEH pump is a centrifugal pump with axial inlet and radial outlet. 
Pump speed is 1450 RPM. 
An  impeller  turns  inside  the  pump  casing  (direction  of  rotation  is 
M 
clockwise  seen  from  drive  end).  The  rotation  movement  is  transmitted 
(N.m) 
to the fluid that is driven to the vanes and then pumped to the discharge 
1450 
flange where it leaves the pump. In the flow passage of the pump casing 
the kinetic energy of the fluid is converted into pressure energy.  
1920 
NOEH pumps are not self‐priming. Suction line and pump casing should 
2350 
be completely filled with liquid before pump start.  
3440 
When  necessary  or  when  a  maximum  pumping  efficiency  is  required 
several possibilities are offered to adapt capacity/pressure. 
5250 
Modification of the system hydraulic characteristics : 
7850 
A  regulating  valve  is  added  at  the  discharge  side  of  the  pump.  The 
hydraulic loss can be adjusted and so the pump duty point. 
10970 
Modification of pump characteristics :  
Use  of a frequency inverter gives the possibility to adjust pump speed. 
The pump hydraulic curve is modified to reach required duty point but 
M 
impeller diameter is unchanged. 
N.m) 
 
1920 
7
INSTALLATION 
2350 
CONNECTION 
3440 
7.1 LOCATION 
5250 
7850 
regulations. 
10970 
 
14890 
The choice of the pump location should permit a proper cooling of the 
motor and should respect following limits : 
10 
SCOPE OF DELIVERY 
AND 
Equipments  that  will  be  used  in  a  ATEX  zone  should  be 
certified accordingly and should fully comply with applicable 
ELECTRICAL 