• When battery pack is not in use, keep it away
from other metal objects, like paper clips, coins,
keys, nails, screws or other small metal objects,
that can make a connection from one terminal
to another. Shorting the battery terminals together
may cause burns or a fire.
• Under abusive conditions, liquid may be ejected
from the battery; avoid contact. If contact ac-
cidentally occurs, flush with water. If liquid
contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation
or burns.
• Do not use a battery pack or tool that is dam-
aged or modified. Damaged or modified batteries
may exhibit unpredictable behavior resulting in fire,
explosion or risk of injury.
• Do not expose a battery pack or tool to fire or
excessive temperature. Exposure to fire or tem-
perature above 265°F (130°C) may cause explosion.
• Follow all charging instructions and do not charge
the battery pack or tool outside the temperature
range specified in the instructions. Charging
improperly or at temperatures outside the specified
range may damage the battery and increase the risk
of fire.
SERVICE
• Have your power tool serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the power
tool is maintained.
• Never service damaged battery packs. Service
of battery packs should only be performed by the
manufacturer or authorized service providers.
SPECIFIC SAFETY RULES FOR
ROTARY TOOL
Safety Warnings Common for Grinding, Sanding,
Wire Brushing, Polishing or Abrasive Cutting-Off
Operations:
• This power tool is intended to function as a
grinder, sander, wire brush, polisher or cut-off
tool. Read all safety warnings, instructions,
illustrations and specifications provided with
this power tool. Failure to follow all instructions
listed below may result in electric shock, fire and/or
serious injury.
• Do not use accessories which are not specifically
designed and recommended by the tool manufac-
turer. Just because the accessory can be attached
to your power tool, it does not assure safe operation.
• The rated speed of the accessory must be at
least equal to the maximum speed marked on
the power tool. Accessories running faster than
their RATED SPEED can break and fly apart.
• The outside diameter and the thickness of your
accessory must be within the capacity rating
of your power tool. Incorrectly sized accessories
cannot be adequately guarded or controlled.
• The arbour size of wheels, flanges, backing pads
or any other accessory must properly fit the
spindle of the power tool. Accessories with arbour
holes that do not match the mounting hardware of the
power tool will run out of balance, vibrate excessively
and may cause loss of control.
• Do not use a damaged accessory. Before each
use inspect the accessory such as abrasive
wheels for chips and cracks, backing pad for
cracks, tear or excess wear, wire brush for loose
or cracked wires. If power tool or accessory is
dropped, inspect for damage or install an undam-
aged accessory. After inspecting and installing
an accessory, position yourself and bystanders
away from the plane of the rotating accessory
and run the power tool at maximum no-load
speed for one minute. Damaged accessories will
normally break apart during this test time.
• Wear personal protective equipment. Depending
on application, use face shield, safety goggles or
safety glasses. As appropriate, wear dust mask,
hearing protectors, gloves and workshop apron
capable of stopping small abrasive or workpiece
fragments. The eye protection must be capable of
stopping flying debris generated by various opera-
tions. The dust mask or respirator must be capable
of filtrating particles generated by your operation.
Prolonged exposure to high intensity noise may
cause hearing loss.
• Keep bystanders a safe distance away from
work area. Anyone entering the work area must
wear personal protective equipment. Fragments
of workpiece or of a broken accessory may fly away
and cause injury beyond immediate area of operation.
• Hold the power tool by insulated gripping surfaces
only, when performing an operation where the
cutting accessory may contact hidden wiring.
Contact with a "live" wire will also make exposed
metal parts of the power tool "live" and could give
the operator an electric shock.
• Never lay the power tool down until the acces-
sory has come to a complete stop. The spinning
accessory may grab the surface and pull the power
tool out of your control.
• Do not run the power tool while carrying it at your
side. Accidental contact with the spinning accessory
could snag your clothing, pulling the accessory into
your body.
• Regularly clean the power tool's air vents. The
motor's fan will draw the dust inside the housing
and excessive accumulation of powdered metal
may cause electrical hazards.
• Do not operate the power tool near flammable
materials. Sparks could ignite these materials.
• Do not use accessories that require liquid cool-
ants. Using water or other liquid coolants may result
in electrocution or shock.
• Allow brushes to run at operating speed for at
least one minute before using them. During this
time no one is to stand in front or in line with the
brush. Loose bristles or wires will be discharged
during the run-in time.
• Direct the discharge of the spinning wire brush
away from you. Small particles and tiny wire frag-
ments may be discharged at high velocity during the
use of these brushes and may become imbedded
in your skin.
• Always feed the bit into the material in the same
direction as the cutting edge is exiting from the
material (which is the same direction as the chips
are thrown). Feeding the tool in the wrong direction
causes the cutting edge of the bit to climb out of the
work and pull the tool in the direction of this feed.